RKI GX-6100 Multi-Gas Detector with alkaline battery pack, LEL/O2/H2S/CO/VOC's, 0 to 4,000 ppm

Modèle: GX-6100 | No. de commande: 72-61ABXX-A

RKI GX-6100 Multi-Gas Detector with alkaline battery pack, LEL/O2/H2S/CO/VOC's, 0 to 4,000 ppm

Modèle: GX-6100 | No. de commande: 72-61ABXX-A

A powerful handheld gas monitor thatcomes with alkaline battery pack measuring LEL, O2, H2S, CO, and VOCs up to 4,000 ppm. It also features two smart channels for PID, PPM, IR, or super-toxic sensors, and can read combustible gases in both PPM and % volume ranges.

A powerful handheld gas monitor thatcomes with alkaline battery pack measuring LEL, O2, H2S, CO, and VOCs up to 4,000 ppm. It also features two smart channels for PID, PPM, IR, or super-toxic sensors, and can read combustible gases in both PPM and % volume ranges.

Prix spécial $4069.97 CAD
Prix régulier $4573.00 CAD
Disponibilité 2 à 3 semaines
Quantité

RKI GX-6100 offre

The GX-6100 is a powerful hand-held instrument capable of simultaneously monitoring up to 6 gases. In addition to the standard 4 confined space gases which include combustibles, O2, CO, & H2S, the GX-6100 has 2 additional smart channels that accept PID, PPM, IR or super toxic sensors. The updated GX-6100 can measure combustible gases in PPM range and %volume in the same monitor.

Equipped with a strong internal sample pump, a man-down alarm, a panic alarm, an LED flashlight, and large auto rotating LCD display, the GX-6100 can operate as a single gas PID unit or a multifunctional tool utilizing all 6 channels. The GX-6100 with a PID sensor will come equipped with a library of over 600 VOC gases to choose from as standard. Choosing from the library is easy with a personalized favorites list of 30 commonly used VOC’s as well as a list of 8 of the most recently used VOC’s. A benzene-specific version is available using a pre-filter tube for detecting low levels of benzene. Four PID sensors are available, 10.0 eV, 10.6 eV (low or high range), and 11.7 eV. Any combination of two PID sensors can be installed. GX-6100 PID sensors are also resistant to humidity.

6 Operating Modes

  • Normal Mode
  • Barhole Mode
  • Inert Mode
  • Leak Check
  • Snap Log Mode
  • Benzene Specific

Caractéristiques

  • Smallest 6 gas sample draw detector
  • New 4-gas sensors with up to 3-year warranty
  • 2 Interchangeable smart sensor slots
  • TC sensor for %volume measurement of combustibles
  • New ppm MOS CH4 and ppm MOS i-C4H10 sensors
  • 4 PID options: 10.6 (2 ranges) eV, 10.0 eV, and 11.7 eV lamps
  • Supports dual PID sensors
  • PID library of over 600 VOCs
  • Rapid sharing of emergency alerts via Bluetooth®
  • Benzene specific version
  • PPM Leak Check mode
  • LEL sensor protection mode
  • Man-down alarm
  • Panic alarm
  • Auto display rotation
  • Peak-bar display
  • LED Light source
  • Internal sample pump
  • Light weight, small, rugged IP-67 design
  • Interchangeable battery packs (Li-ion / alkaline)
  • Operates up to 28 hours on Li-ion battery pack, 8 hours operation with alkaline pack
  • Field replaceable sensors, batteries, filters and pump
  • Intrinsically safe ATEX / IECEx / cCSAus (pending)

Applications

  • Confined space entry
  • Hazmat response teams
  • Arson investigation
  • Remediation ste
  • Perimeter monitoring
  • Leak detection
  • Landfill monitoring
  • Winery tank entry

Spécifications pour le RKI GX-6100

PID Sensors
10.6 Lamp - 600 VOC’s Detection Range: 0 to 4,000 ppm
Reading Increment: 0.1 ppm (< 600 ppm)
1 ppm (> 600 ppm)
Alarm Set Points: A1: 400 ppm
A2: 1,000 ppm
A3: 1,000 ppm
Accuracy: ±10% of reading, ±1 digit
Electro Chemical R Sensor
Oxygen (O2) Detection Range: 0 to 40.0% Vol.
Reading Increment: 0.1% Vol.
Alarm Set Points: A1: 19.5 Vol
A2: 18 Vol
A3: 23.5 Vol
Accuracy: ±0.5% O2
Carbon Monoxide (CO) Detection Range: 0 to 2,000 ppm
Reading Increment: 1 ppm
Alarm Set Points: A1: 25 ppm
A2: 50 ppm
A3: 1,200 ppm
TWA: 25 ppm
STEL: 200 ppm
Accuracy: ±5% of reading or ±5 ppm
Hydrogen Sulfide (H2S) Detection Range: 0 to 200 ppm
Reading Increment: 0.5 ppm
Alarm Set Points: A1: 5.0 ppm
A2: 30.0 ppm
A3: 100.0 ppm
TWA: 1.0 ppm
STEL: 5.0 ppm
Accuracy: ±5% of reading or ±2 ppm
Smart Sensors NDIR
Carbon Dioxide (CO2) NDIR Detection Range: 0 to 10,000 ppm
0 to 10.00% Vol.
Reading Increment: 20 ppm
0.02%
Alarm Set Points (ppm): A1: 5,000 ppm
TWA: 5,000 ppm
Alarm Set Points (%Vol): A1: 0.50% Vol.
A2: 3.00% Vol.
A3: 3.00% Vol.
STEL: 3.00% Vol.
TWA: 0.50% Vol.
Accuracy: ±5% of reading or ±2% of full scale
Methane NDIR Detection Range: 0 to 100% LEL
0 to 100% Vol.
Reading Increment: 1% LEL
0.5% Vol
Alarm Set Points: A1: 10% LEL
A2: 50% LEL
A3: 50% LEL
Accuracy: ±5% of reading or ±2% of full scale
Isobutane NDIR Detection Range: 0 to 100% LEL
0 to 30% Vol.
Reading Increment: 1% LEL
0.5% Vol
Alarm Set Points: A1: 10% LEL
A2: 50% LEL
A3: 50% LEL
Accuracy: ±5% of reading or ±2% of full scale
Smart Sensor (hot-wire semiconductor) MOS
Methane Detection Range: 0 to 5,000 ppm
Reading Increment: 10 ppm
Alarm Set Points: N/A
Accuracy: N/A
Isobutane Detection Range: 0 to 2,000 ppm
Reading Increment: 10 ppm
Alarm Set Points: N/A
Accuracy: N/A
R Sensor (new ceramic type)
Hydrocarbons (CH4, std) Detection Range: 0 to 100% LEL
Reading Increment: 1% LEL
Alarm Set Points: A1: 10% LEL
A2: 25% LEL
A3: 50% LEL
Accuracy: ±5% of reading or ±2% LEL
TE Sensor (thermal conductivity)
Methane CH4 Detection Range: 0 to 100 vol%
Reading Increment: 1% vol%
Alarm Set Points: N/A
Accuracy: N/A
General Specifications
Alarm Types Gas alarm: Low and high adjustable
Trouble: Low flow, Sensor connection, Low battery, Circuit error, Calibration failure
Man Down Alarm
Panic Alarm
Display Digital LCD, autobacklight, peak bar display, auto display rotation, and customize order of gases
Communication Bluetooth, IrDA
Audible Alarm 95 dB at 1' (0.30 m)
Languages English, Japanese, French, Spanish, Portuguese, Italian, German, Russian, Korean, Chinese (simplified), Chinese (traditional), Vietnamese, Slovak, Czech, Turkish, Polish
Continuous Operation 28 hours on Lithium-ion battery pack. Complete recharge in 6 hours.
8 hours Alkaline battery pack (3 AA size in each pack)
Operating Temp. & Humidity -4 to 122°F (-20 to 50°C), 0 to 95% RH non condensing
Case Material Dust and water resistant with IP-67 approval (exclude sample hose and probe)
Warranty Three years material (including R sensors) and workmanship
2 years for IR sensors and ESS (except Cl2)
One year for TE, Cl2 and PID sensors
(Two months for T1.7 eV lamp)
Dimensions 2.6 x 7.9 x 2.2" (6.60 x 20.07 x 5.59 cm)
Weight 17.6 oz (500 g) with lithium battery pack
16 oz (450 g) with alkaline batteries

Le RKI GX-6100 comprend

  • Multigas Detector
  • Rubber Foot
  • Belt Clip
  • Hand Strap
  • Tapper Nozzle
  • Probe with Hydrophobic and Dust Filter
  • 3' (0.91 m) Teflon Lined Hose
  • Alkaline Battery Pack

Poser une question sur le RKI GX-6100 Multi-Gas Detector with alkaline battery pack, LEL/O2/H2S/CO/VOC's, 0 to 4,000 ppm

RKI GX-6100 offre

The GX-6100 is a powerful hand-held instrument capable of simultaneously monitoring up to 6 gases. In addition to the standard 4 confined space gases which include combustibles, O2, CO, & H2S, the GX-6100 has 2 additional smart channels that accept PID, PPM, IR or super toxic sensors. The updated GX-6100 can measure combustible gases in PPM range and %volume in the same monitor.

Equipped with a strong internal sample pump, a man-down alarm, a panic alarm, an LED flashlight, and large auto rotating LCD display, the GX-6100 can operate as a single gas PID unit or a multifunctional tool utilizing all 6 channels. The GX-6100 with a PID sensor will come equipped with a library of over 600 VOC gases to choose from as standard. Choosing from the library is easy with a personalized favorites list of 30 commonly used VOC’s as well as a list of 8 of the most recently used VOC’s. A benzene-specific version is available using a pre-filter tube for detecting low levels of benzene. Four PID sensors are available, 10.0 eV, 10.6 eV (low or high range), and 11.7 eV. Any combination of two PID sensors can be installed. GX-6100 PID sensors are also resistant to humidity.

6 Operating Modes

  • Normal Mode
  • Barhole Mode
  • Inert Mode
  • Leak Check
  • Snap Log Mode
  • Benzene Specific

Caractéristiques

  • Smallest 6 gas sample draw detector
  • New 4-gas sensors with up to 3-year warranty
  • 2 Interchangeable smart sensor slots
  • TC sensor for %volume measurement of combustibles
  • New ppm MOS CH4 and ppm MOS i-C4H10 sensors
  • 4 PID options: 10.6 (2 ranges) eV, 10.0 eV, and 11.7 eV lamps
  • Supports dual PID sensors
  • PID library of over 600 VOCs
  • Rapid sharing of emergency alerts via Bluetooth®
  • Benzene specific version
  • PPM Leak Check mode
  • LEL sensor protection mode
  • Man-down alarm
  • Panic alarm
  • Auto display rotation
  • Peak-bar display
  • LED Light source
  • Internal sample pump
  • Light weight, small, rugged IP-67 design
  • Interchangeable battery packs (Li-ion / alkaline)
  • Operates up to 28 hours on Li-ion battery pack, 8 hours operation with alkaline pack
  • Field replaceable sensors, batteries, filters and pump
  • Intrinsically safe ATEX / IECEx / cCSAus (pending)

Applications

  • Confined space entry
  • Hazmat response teams
  • Arson investigation
  • Remediation ste
  • Perimeter monitoring
  • Leak detection
  • Landfill monitoring
  • Winery tank entry

Spécifications pour le RKI GX-6100

PID Sensors
10.6 Lamp - 600 VOC’s Detection Range: 0 to 4,000 ppm
Reading Increment: 0.1 ppm (< 600 ppm)
1 ppm (> 600 ppm)
Alarm Set Points: A1: 400 ppm
A2: 1,000 ppm
A3: 1,000 ppm
Accuracy: ±10% of reading, ±1 digit
Electro Chemical R Sensor
Oxygen (O2) Detection Range: 0 to 40.0% Vol.
Reading Increment: 0.1% Vol.
Alarm Set Points: A1: 19.5 Vol
A2: 18 Vol
A3: 23.5 Vol
Accuracy: ±0.5% O2
Carbon Monoxide (CO) Detection Range: 0 to 2,000 ppm
Reading Increment: 1 ppm
Alarm Set Points: A1: 25 ppm
A2: 50 ppm
A3: 1,200 ppm
TWA: 25 ppm
STEL: 200 ppm
Accuracy: ±5% of reading or ±5 ppm
Hydrogen Sulfide (H2S) Detection Range: 0 to 200 ppm
Reading Increment: 0.5 ppm
Alarm Set Points: A1: 5.0 ppm
A2: 30.0 ppm
A3: 100.0 ppm
TWA: 1.0 ppm
STEL: 5.0 ppm
Accuracy: ±5% of reading or ±2 ppm
Smart Sensors NDIR
Carbon Dioxide (CO2) NDIR Detection Range: 0 to 10,000 ppm
0 to 10.00% Vol.
Reading Increment: 20 ppm
0.02%
Alarm Set Points (ppm): A1: 5,000 ppm
TWA: 5,000 ppm
Alarm Set Points (%Vol): A1: 0.50% Vol.
A2: 3.00% Vol.
A3: 3.00% Vol.
STEL: 3.00% Vol.
TWA: 0.50% Vol.
Accuracy: ±5% of reading or ±2% of full scale
Methane NDIR Detection Range: 0 to 100% LEL
0 to 100% Vol.
Reading Increment: 1% LEL
0.5% Vol
Alarm Set Points: A1: 10% LEL
A2: 50% LEL
A3: 50% LEL
Accuracy: ±5% of reading or ±2% of full scale
Isobutane NDIR Detection Range: 0 to 100% LEL
0 to 30% Vol.
Reading Increment: 1% LEL
0.5% Vol
Alarm Set Points: A1: 10% LEL
A2: 50% LEL
A3: 50% LEL
Accuracy: ±5% of reading or ±2% of full scale
Smart Sensor (hot-wire semiconductor) MOS
Methane Detection Range: 0 to 5,000 ppm
Reading Increment: 10 ppm
Alarm Set Points: N/A
Accuracy: N/A
Isobutane Detection Range: 0 to 2,000 ppm
Reading Increment: 10 ppm
Alarm Set Points: N/A
Accuracy: N/A
R Sensor (new ceramic type)
Hydrocarbons (CH4, std) Detection Range: 0 to 100% LEL
Reading Increment: 1% LEL
Alarm Set Points: A1: 10% LEL
A2: 25% LEL
A3: 50% LEL
Accuracy: ±5% of reading or ±2% LEL
TE Sensor (thermal conductivity)
Methane CH4 Detection Range: 0 to 100 vol%
Reading Increment: 1% vol%
Alarm Set Points: N/A
Accuracy: N/A
General Specifications
Alarm Types Gas alarm: Low and high adjustable
Trouble: Low flow, Sensor connection, Low battery, Circuit error, Calibration failure
Man Down Alarm
Panic Alarm
Display Digital LCD, autobacklight, peak bar display, auto display rotation, and customize order of gases
Communication Bluetooth, IrDA
Audible Alarm 95 dB at 1' (0.30 m)
Languages English, Japanese, French, Spanish, Portuguese, Italian, German, Russian, Korean, Chinese (simplified), Chinese (traditional), Vietnamese, Slovak, Czech, Turkish, Polish
Continuous Operation 28 hours on Lithium-ion battery pack. Complete recharge in 6 hours.
8 hours Alkaline battery pack (3 AA size in each pack)
Operating Temp. & Humidity -4 to 122°F (-20 to 50°C), 0 to 95% RH non condensing
Case Material Dust and water resistant with IP-67 approval (exclude sample hose and probe)
Warranty Three years material (including R sensors) and workmanship
2 years for IR sensors and ESS (except Cl2)
One year for TE, Cl2 and PID sensors
(Two months for T1.7 eV lamp)
Dimensions 2.6 x 7.9 x 2.2" (6.60 x 20.07 x 5.59 cm)
Weight 17.6 oz (500 g) with lithium battery pack
16 oz (450 g) with alkaline batteries

Le RKI GX-6100 comprend

  • Multigas Detector
  • Rubber Foot
  • Belt Clip
  • Hand Strap
  • Tapper Nozzle
  • Probe with Hydrophobic and Dust Filter
  • 3' (0.91 m) Teflon Lined Hose
  • Alkaline Battery Pack

Poser une question sur le RKI GX-6100 Multi-Gas Detector with alkaline battery pack, LEL/O2/H2S/CO/VOC's, 0 to 4,000 ppm

Plus de produits RKI