RKI 725-106-05-P2 EAGLE 2 IR/PID Gas Detector for hydrocarbons/LEL/ppm, H₂/O₂/CO₂/VOCs

Modèle: 725-126-05-P2

RKI 725-106-05-P2 EAGLE 2 IR/PID Gas Detector for hydrocarbons/LEL/ppm, H₂/O₂/CO₂/VOCs

Modèle: 725-126-05-P2

The IR gas detector is built to measure the amount of H₂, O₂ CO₂ or VOCs in your space. The unit features IR and PID sensors to suit your needs.

The IR gas detector is built to measure the amount of H₂, O₂ CO₂ or VOCs in your space. The unit features IR and PID sensors to suit your needs.

Discontinué!

Ce produit a été discontinué et n’est plus disponible. Il n’y a pas de produit de remplacement direct. Ne vous inquiétez pas, nous avons quelques options pour vous aider à trouver ce dont vous avez besoin:

Visitez notre catégorie Détecteurs de gaz multiples portables pour trouver des produits similaires.

Ou nous ferons une recherche et vous aiderons à trouver ce dont vous avez besoin:


RKI 725-126-05-P2 Offers



With the RKI 725-106-05-P2 EAGLE 2 IR/PID Gas Detector for hydrocarbons/LEL/ppm, you can efficiently test for the amount of oxygen, hydrogen and carbon dioxide in your space. The unit detects the presence of hydrocarbons using infrared and PID sensors. The detector's strong, internal low-flow pump allows for the capture of drawing samples from up to 125' (38.1 m) away.

Features

  • Provides PPM or LEL (catalytic) and hydrocarbon detection at the push of a button
  • Equipped with infrared sensors to measure in LEL or percentage volume ranges
  • PID sensor detects ppm of VOC gases from 0 to 2,000 ppm
  • Features an autoranging design to suit your needs
  • Methane elimination is available for environmental applications
  • Data logging capability allows you to review the results later
  • Requires a standard IrDA/USB cable (47-5027RK) to download the data
  • Alkaline battery power provides up to 18 hours of continuous operation
  • Factory calibration of LEL/ppm ranges is to methane; factory calibration of PID sensor is to isobutylene

RKI 725-126-05-P2 Specifications


AlarmsAlarm
Auto Shut OffYes
Battery RequiredYes
Battery SizeC
Battery TypeAlkaline; NiMH
Compatible GasesH₂, O₂, CO₂, VOCs
Detection MethodInfrared, PID
Measurement RangeHydrocarbons: 100% LEL, 30% of volume; VOCs: 0 to 2,000 ppm; O₂/CO₂: 60% of volume
Cliquer ici pour toutes les spécifications du RKI 725-126-05-P2

What's included with the RKI 725-126-05-P2


  • Gas Detector
  • 13-0100RK Shoulder Strap with RKI Logo for EAGLE/EAGLE 2
  • 33-0173RK Internal Hydrophobic Filter for EAGLE 2
  • 49-1130RK C Alkaline Battery
  • 71-8003RK EAGLE 2 Product CD
  • 80-0131RK-20 10" (254 mm) Standard Hydrophobic Probe with metal fittings for EAGLE 2 with PID
  • 80-0131RK-10 10" (254 mm) Standard Hydrophobic Probe with Particle Filter and Metal Fittings
  • 80-0505RK 5' (1.52 m) Polyurethane Hose with Fittings
  • 80-0605RK 5' (1.52 m) Teflon-Lined Hose with Fittings

Poser une question sur le RKI 725-106-05-P2 EAGLE 2 IR/PID Gas Detector for hydrocarbons/LEL/ppm, H₂/O₂/CO₂/VOCs

RKI 725-126-05-P2 Offers



With the RKI 725-106-05-P2 EAGLE 2 IR/PID Gas Detector for hydrocarbons/LEL/ppm, you can efficiently test for the amount of oxygen, hydrogen and carbon dioxide in your space. The unit detects the presence of hydrocarbons using infrared and PID sensors. The detector's strong, internal low-flow pump allows for the capture of drawing samples from up to 125' (38.1 m) away.

Features

  • Provides PPM or LEL (catalytic) and hydrocarbon detection at the push of a button
  • Equipped with infrared sensors to measure in LEL or percentage volume ranges
  • PID sensor detects ppm of VOC gases from 0 to 2,000 ppm
  • Features an autoranging design to suit your needs
  • Methane elimination is available for environmental applications
  • Data logging capability allows you to review the results later
  • Requires a standard IrDA/USB cable (47-5027RK) to download the data
  • Alkaline battery power provides up to 18 hours of continuous operation
  • Factory calibration of LEL/ppm ranges is to methane; factory calibration of PID sensor is to isobutylene

RKI 725-126-05-P2 Specifications


AlarmsAlarm
Auto Shut OffYes
Battery RequiredYes
Battery SizeC
Battery TypeAlkaline; NiMH
Compatible GasesH₂, O₂, CO₂, VOCs
Detection MethodInfrared, PID
Measurement RangeHydrocarbons: 100% LEL, 30% of volume; VOCs: 0 to 2,000 ppm; O₂/CO₂: 60% of volume
Cliquer ici pour toutes les spécifications du RKI 725-126-05-P2

What's included with the RKI 725-126-05-P2


  • Gas Detector
  • 13-0100RK Shoulder Strap with RKI Logo for EAGLE/EAGLE 2
  • 33-0173RK Internal Hydrophobic Filter for EAGLE 2
  • 49-1130RK C Alkaline Battery
  • 71-8003RK EAGLE 2 Product CD
  • 80-0131RK-20 10" (254 mm) Standard Hydrophobic Probe with metal fittings for EAGLE 2 with PID
  • 80-0131RK-10 10" (254 mm) Standard Hydrophobic Probe with Particle Filter and Metal Fittings
  • 80-0505RK 5' (1.52 m) Polyurethane Hose with Fittings
  • 80-0605RK 5' (1.52 m) Teflon-Lined Hose with Fittings

Poser une question sur le RKI 725-106-05-P2 EAGLE 2 IR/PID Gas Detector for hydrocarbons/LEL/ppm, H₂/O₂/CO₂/VOCs