RKI 65-2301RK-HCN Hydrogen Cyanide Sensor, 0 to 15 ppm, direct connection

Modèle: 65-2301RK-HCN

RKI 65-2301RK-HCN Hydrogen Cyanide Sensor, 0 to 15 ppm, direct connection

Modèle: 65-2301RK-HCN

Highly reliable, this sensor is effective for the detection of common gas hazards and provides high specificity. Non-explosion proof, this electrochemical type plug-in sensor allows quick replacement and in the field with no tools required, and can function in Class I, Div. 2 hazardous locations.

Highly reliable, this sensor is effective for the detection of common gas hazards and provides high specificity. Non-explosion proof, this electrochemical type plug-in sensor allows quick replacement and in the field with no tools required, and can function in Class I, Div. 2 hazardous locations.

Prix spécial $1017.27 CAD
Prix régulier $1143.00 CAD
Disponibilité 2 à 3 semaines
Quantité

RKI 65-2301RK-HCN offre

All of the Direct Connect sensors are designed to specifically interface with RKI Beacon 110, 200, and 410 controllers, and can be used both indoors and outdoors.

Caractéristiques

  • LEL, H2S, CO, CO2
  • Toxic sensors include NH3, AsH3, HCN, and PH3, and SO2
  • Infrared sensor for combustibles and CO2
  • Patented water repellent sensor coating
  • Non-explosion proof

Spécifications pour le RKI 65-2301RK-HCN

Sensor Electrochemical
Gas Hydrogen Cyanide
Measuring Range 0 to 15 ppm
Lower Detectable Limit (LDL) 2% of full scale
Response Time (T-90) 60 seconds or less
Life Expectancy 2 to 3 years with normal service
Warranty One year materials and workmanship

Le RKI 65-2301RK-HCN comprend

  • RKI 65-2301RK-HCN Hydrogen Cyanide Sensor, 0 to 15 ppm, direct connection

Poser une question sur le RKI 65-2301RK-HCN Hydrogen Cyanide Sensor, 0 to 15 ppm, direct connection

RKI 65-2301RK-HCN offre

All of the Direct Connect sensors are designed to specifically interface with RKI Beacon 110, 200, and 410 controllers, and can be used both indoors and outdoors.

Caractéristiques

  • LEL, H2S, CO, CO2
  • Toxic sensors include NH3, AsH3, HCN, and PH3, and SO2
  • Infrared sensor for combustibles and CO2
  • Patented water repellent sensor coating
  • Non-explosion proof

Spécifications pour le RKI 65-2301RK-HCN

Sensor Electrochemical
Gas Hydrogen Cyanide
Measuring Range 0 to 15 ppm
Lower Detectable Limit (LDL) 2% of full scale
Response Time (T-90) 60 seconds or less
Life Expectancy 2 to 3 years with normal service
Warranty One year materials and workmanship

Le RKI 65-2301RK-HCN comprend

  • RKI 65-2301RK-HCN Hydrogen Cyanide Sensor, 0 to 15 ppm, direct connection

Poser une question sur le RKI 65-2301RK-HCN Hydrogen Cyanide Sensor, 0 to 15 ppm, direct connection