Designed to quickly detect, trace, and pinpoint virtual ground faults in live DC systems where electrical cables have breakage with the current loss to the ground. Without signal injection to the tested circuit, it is safe during signal tracing, and signal comparison and direction indication make it fast to trace the signal fault.
Designed to quickly detect, trace, and pinpoint virtual ground faults in live DC systems where electrical cables have breakage with the current loss to the ground. Without signal injection to the tested circuit, it is safe during signal tracing, and signal comparison and direction indication make it fast to trace the signal fault.
Discontinué!
Ce produit a été discontinué et n’est plus disponible.
Il n’y a pas de remplacement direct, mais nous vous recommandons:
Vous ne trouvez pas ce que vous cherchez? Nous ferons une recherche et vous aiderons à trouver ce dont vous avez besoin.
Caractéristiques
Functions
Applications
| Signal Analyzer | |
| Operating Environment | Working power: DC 40 to 300 V Temperature: -4 to 131°F (-20 to 55°C) Humidity: 0 to 90% |
| DC Voltage Measurement | Measurement range: 0 to 300 V Resolution: 0.1 V Accuracy: 0.2% |
| AC Voltage Measurement | Measurement range: 0 to 300 V Resolution: 0.1 V Accuracy: 0.5% |
| Insulation Resistance Measurement | Measurement range: 0 to 999.9 KΩ Resolution: 0.1 KΩ Accuracy: ≤±5% |
| Measurement Bridge | Adjustment range: 0, 0.25, 0.5, 1, 2 mA Frequency range: 0.25 Hz |
| Grounding Detection Range | Up to 200 KΩ |
| Distributed Capacitance Measurement | Measurement range: 0 to 999 μF |
| Measurement Waveform | Square wave and sine wave |
| Working Mode | Compulsory signal and automatic signal |
| Display | 320 x 240 pixels TFT |
| Power Supply | Powered by tested circuit |
| Dimensions | 7.87 x 5.71 x 2.95" (200 x 145 x 75 mm) |
| Weight | 1 lb (0.45 kg) |
| Signal Detector | |
| Grounding Resistance Measurement | Measurement range: 0 to 500 KΩ Resolution: 0.1 KΩ Accuracy: ≤±10% |
| Frequency Spectrum Analysis | Number of channel: 1 Frequency range: 0.125 to 12.5 Hz Resolution: 0.125 Hz |
| Display Period of Current Waveform | 8 s |
| Measuring Range for Feeder | 0 to 2 A |
| Current Measurement Range | -100 to 100 mA |
| Current Resolution | 0.01 mA |
| Display | 320 x 240 pixel TFT |
| Clamp Jaw Size | Ø30 mm and Ø40mm |
| Power Supply | 5 V by 4 x of AA standard battery |
| Dimensions | 8.46 x 3.94 x 1.3" (215 x 100 x 33 mm) |
| Weight | 0.67 lb (0.303 kg) |
| Signal Analyzer | |
| Operating Environment | Working power: DC 40 to 300 V Temperature: -4 to 131°F (-20 to 55°C) Humidity: 0 to 90% |
| DC Voltage Measurement | Measurement range: 0 to 300 V Resolution: 0.1 V Accuracy: 0.2% |
| AC Voltage Measurement | Measurement range: 0 to 300 V Resolution: 0.1 V Accuracy: 0.5% |
| Insulation Resistance Measurement | Measurement range: 0 to 999.9 KΩ Resolution: 0.1 KΩ Accuracy: ≤±5% |
| Measurement Bridge | Adjustment range: 0, 0.25, 0.5, 1, 2 mA Frequency range: 0.25 Hz |
| Grounding Detection Range | Up to 200 KΩ |
| Distributed Capacitance Measurement | Measurement range: 0 to 999 μF |
| Measurement Waveform | Square wave and sine wave |
| Working Mode | Compulsory signal and automatic signal |
| Display | 320 x 240 pixels TFT |
| Power Supply | Powered by tested circuit |
| Dimensions | 7.87 x 5.71 x 2.95" (200 x 145 x 75 mm) |
| Weight | 1 lb (0.45 kg) |
| Signal Detector | |
| Grounding Resistance Measurement | Measurement range: 0 to 500 KΩ Resolution: 0.1 KΩ Accuracy: ≤±10% |
| Frequency Spectrum Analysis | Number of channel: 1 Frequency range: 0.125 to 12.5 Hz Resolution: 0.125 Hz |
| Display Period of Current Waveform | 8 s |
| Measuring Range for Feeder | 0 to 2 A |
| Current Measurement Range | -100 to 100 mA |
| Current Resolution | 0.01 mA |
| Display | 320 x 240 pixel TFT |
| Clamp Jaw Size | Ø30 mm and Ø40mm |
| Power Supply | 5 V by 4 x of AA standard battery |
| Dimensions | 8.46 x 3.94 x 1.3" (215 x 100 x 33 mm) |
| Weight | 0.67 lb (0.303 kg) |