The CTi 2M series utilizes short-wavelength measurements with a spectral range of 0 to 1.6 μm to provide precise non-contact temperature measurement in hot-metal applications. This has a measuring temperature range of 914 to 3632°F (490 to 2000°C), optical resolution of 75:1, standard focus lens, and 9.8' (3 m) cable.
The CTi 2M series utilizes short-wavelength measurements with a spectral range of 0 to 1.6 μm to provide precise non-contact temperature measurement in hot-metal applications. This has a measuring temperature range of 914 to 3632°F (490 to 2000°C), optical resolution of 75:1, standard focus lens, and 9.8' (3 m) cable.
The Optris CTi 2M infrared pyrometer utilizes short-wavelength measurement technology at 1.6 μm to provide precise non-contact temperature measurement in demanding hot-metal applications. This short spectral range significantly reduces measurement errors caused by low or varying emissivity, ensuring stable and repeatable results. An advanced InGaAs detector enables accurate temperature measurement of metals, metal oxides, ceramics, and semiconductor materials at high temperatures. With a distance-to-spot ratio of up to 75:1, the pyrometer delivers reliable measurements of small targets even from extended distances. Its compact design and fast response time of 320 μs make the CTi 2M well suited for integration into high-speed industrial processes and heavy machinery.
Caractéristiques
Applications
| Environmental Rating | IP 65 (NEMA-4) |
| Operating Temperature | -4 to 257°F (-20 to 125°C) (sensing head) -4 to 185°F (-20 to 85°C) (electronics) |
| Storage Temperature | -40 to 257°F (-20 to 125°C) (sensing head) -40 to 185°F (-20 to 85°C) (electronics) |
| Operating air Humidity Range | 10 to 95 %, non-condensing |
| Vibration (sensor) | IEC 60068-2-6 (sinus shaped) IEC 60068-2-64 (broadband noise) |
| Shock (Sensor) | IEC 60068-2-27 (25G and 50G) |
| Output/Analog) | 0/4 to 20 mA, 0 to 5 / 10 V, thermocouple K, alarm |
| Output/Alarm | 24 V/ 50 mA (open collector) |
| Relay Outputs (optional) | Relay: 2 x 60 V DC/ 42 V ACRMS; 0.4 A; optically isolated |
| Digital Interfaces | built-in USB-interface, Optional: EtherNet/IP, Profinet, Ethernet TCP/IP / Modbus TCP, Modbus RTU, RS485, RS232 or relay outputs (2 x optically isolated) |
| Output Impendances | mA max. 500 Ω (with 8 to 36 V DC) mV min. 100 kΩ load impedance thermocouple 20 Ω |
| I/O Pins (3x) | Flexible programming as in- or output: external emissivity adjustment, ambient temperature compensation, uncommitted value, trigger (reset of hold functions), alarm output (open collector 24 V / 50 mA) |
| Cable Length | 9.8' (3 m) |
| Power Supply | 8 to 36 V DC / 1.2 W |
| Measuring Temperature Range | 914 to 3632°F (490 to 2000°C) |
| Spectral Range | 1.6 μm |
| Optical Resolution (90%) | 75:1 |
| Measurment Uncertainty | ± (0.3% of reading +1.5°C) |
| Repeatability | ± 0.25 K |
| Temperature Coefficient | ± 0.20 K/K |
| NETD (Typically) | 52 mK |
| Temperature Resolution (display) | 0.1 K |
| Exposure Time | 110 μs |
| Response Time (90% energy) | 320 μs |
| Emmisivity/Gain | 0.05 to 1.1 |
| Transmissivity/Gain | 0.05 to 1.1 |
| Signal Processing | Peak hold, valley hold, average; extended hold functions with threshold and hysteresis |
| Software/Ap[p | Optris CompactPlus Connect / IRmobile App |
| Dimension | Sensing head: Ø0.5 in x 1.4" (Ø12 x 35 mm), M12x1 Electronics: 4.8 x 2.8 x 1.1" (122 x 70 x 27 mm) |
| Weight | 1.41 oz (40 g) (sensing head) 14.82 oz (420 g) (electronics) |
| Environmental Rating | IP 65 (NEMA-4) |
| Operating Temperature | -4 to 257°F (-20 to 125°C) (sensing head) -4 to 185°F (-20 to 85°C) (electronics) |
| Storage Temperature | -40 to 257°F (-20 to 125°C) (sensing head) -40 to 185°F (-20 to 85°C) (electronics) |
| Operating air Humidity Range | 10 to 95 %, non-condensing |
| Vibration (sensor) | IEC 60068-2-6 (sinus shaped) IEC 60068-2-64 (broadband noise) |
| Shock (Sensor) | IEC 60068-2-27 (25G and 50G) |
| Output/Analog) | 0/4 to 20 mA, 0 to 5 / 10 V, thermocouple K, alarm |
| Output/Alarm | 24 V/ 50 mA (open collector) |
| Relay Outputs (optional) | Relay: 2 x 60 V DC/ 42 V ACRMS; 0.4 A; optically isolated |
| Digital Interfaces | built-in USB-interface, Optional: EtherNet/IP, Profinet, Ethernet TCP/IP / Modbus TCP, Modbus RTU, RS485, RS232 or relay outputs (2 x optically isolated) |
| Output Impendances | mA max. 500 Ω (with 8 to 36 V DC) mV min. 100 kΩ load impedance thermocouple 20 Ω |
| I/O Pins (3x) | Flexible programming as in- or output: external emissivity adjustment, ambient temperature compensation, uncommitted value, trigger (reset of hold functions), alarm output (open collector 24 V / 50 mA) |
| Cable Length | 9.8' (3 m) |
| Power Supply | 8 to 36 V DC / 1.2 W |
| Measuring Temperature Range | 914 to 3632°F (490 to 2000°C) |
| Spectral Range | 1.6 μm |
| Optical Resolution (90%) | 75:1 |
| Measurment Uncertainty | ± (0.3% of reading +1.5°C) |
| Repeatability | ± 0.25 K |
| Temperature Coefficient | ± 0.20 K/K |
| NETD (Typically) | 52 mK |
| Temperature Resolution (display) | 0.1 K |
| Exposure Time | 110 μs |
| Response Time (90% energy) | 320 μs |
| Emmisivity/Gain | 0.05 to 1.1 |
| Transmissivity/Gain | 0.05 to 1.1 |
| Signal Processing | Peak hold, valley hold, average; extended hold functions with threshold and hysteresis |
| Software/Ap[p | Optris CompactPlus Connect / IRmobile App |
| Dimension | Sensing head: Ø0.5 in x 1.4" (Ø12 x 35 mm), M12x1 Electronics: 4.8 x 2.8 x 1.1" (122 x 70 x 27 mm) |
| Weight | 1.41 oz (40 g) (sensing head) 14.82 oz (420 g) (electronics) |