Record temperatures in indoor environments with this single-channel thermocouple data logger. Designed for a broad range of temperature monitoring applications, this data logger is compatible with J, K, T, E, R, S, B, or N-type thermocouple probes.
Record temperatures in indoor environments with this single-channel thermocouple data logger. Designed for a broad range of temperature monitoring applications, this data logger is compatible with J, K, T, E, R, S, B, or N-type thermocouple probes.
Records temperature and relative humidity (within 2.5% accuracy) in indoor environments with the integrated sensor, this logger is ideal for monitoring occupant comfort in office buildings, tracking food storage conditions in warehouses, and logging temperature trends in server rooms.
This data logger requires a compatible mobile device or Windows computer and the HOBOconnect app.
Features
In what environment does this data logger operate?
Supported measurements
Applications
Download the mobile App
Thermocouple | |
J | Range: -346 to 1400°F (-210 to 760°C) Accuracy: ±1.08°F (±0.6°C) ±thermocouple probe accuracy Resolution: 0.06°F (0.03°C) |
K | Range: -436 to 2498°F (-260 to 1370°C) Accuracy: ±1.26°F (±0.7°C) ±thermocouple probe accuracy Resolution: 0.07°F (0.04°C) |
T | Range: -436 to 752°F (-260 to 400°C) Accuracy: ±1.08°F (±0.6°C) ±thermocouple probe accuracy Resolution: 0.03°F (0.02°C) |
E | Range: -436 to 1742°F (-260 to 950°C) Accuracy: ±1.08°F (±0.6°C) ±thermocouple probe accuracy Resolution: 0.05°F at (0.03°C) |
R | Range: -58 to 2822°F (-50 to 1550°C) Accuracy: ±3.96°F (±2.2°C) ±thermocouple probe accuracy Resolution: 0.15°F (0.08°C) |
S | Range: -58 to 3128°F (-50 to 1720°C) Accuracy: ±3.96°F (±2.2°C) ±thermocouple probe accuracy Resolution: 0.15°F (0.08°C) |
B | Range: 1022 to 3308°F (550 to 1820°C) Accuracy: ±4.5°F (±2.5°C) ±thermocouple probe accuracy Resolution: 0.18°F (0.1°C) |
N | Range: -436 to 2372°F (-260 to 1300°C) Accuracy: ±1.8°F (±1.0°C) ±thermocouple probe accuracy Resolution: 0.11°F (0.06°C) |
Internal 10K Thermistor (Temperature) | |
Logging Range | -4 to 158°F (-20 to 70°C) |
Accuracy | ±0.38°F from 32 to 122°F (±0.21°C from 0 to 50°C) |
Resolution | 0.04°F at 77°F (0.024°C at 25°C) |
Drift | 0.18°F (<0.1°C) per year |
Logger | |
Operating Range | Logging: -4 to 158°F (-20 to 70°C); 0 to 95% RH (non-condensing); logger accuracy from 32 to 122°F (0 to 50°C) Launch/Readout: 32 to 122°F (0 to 50°C) per USB specification |
Resolution | 22-bit |
Logging | Rate: 1 second to 18 hours, 12 minutes, 15 seconds Modes: Normal, Burst or Statistics |
Modes | Memory: Wrap when full or stop when full Start: Immediately, push button, date and time or next interval Stop: When memory full, push button, or date and time Restart: Push button |
Time Accuracy | ±1 minute per month at 77°F (25°C) |
Battery | Life: 1 year, typical with logging rate of 1 minute and sampling interval of 15 seconds or greater Type: 1 x 3 V CR2032 lithium battery |
Environmental Rating | IP50 |
Dimensions | 1.44 x 2.34 x 0.6" (3.66 x 5.94 x 1.52 cm) |
Weight | 1.06 oz (30 g) |
Cliquer sur une catégorie pour voir une sélection d'accessoires compatible avec le Onset HOBO UX100-014M Thermocouple Data Logger, single-channel.
Thermocouple | |
J | Range: -346 to 1400°F (-210 to 760°C) Accuracy: ±1.08°F (±0.6°C) ±thermocouple probe accuracy Resolution: 0.06°F (0.03°C) |
K | Range: -436 to 2498°F (-260 to 1370°C) Accuracy: ±1.26°F (±0.7°C) ±thermocouple probe accuracy Resolution: 0.07°F (0.04°C) |
T | Range: -436 to 752°F (-260 to 400°C) Accuracy: ±1.08°F (±0.6°C) ±thermocouple probe accuracy Resolution: 0.03°F (0.02°C) |
E | Range: -436 to 1742°F (-260 to 950°C) Accuracy: ±1.08°F (±0.6°C) ±thermocouple probe accuracy Resolution: 0.05°F at (0.03°C) |
R | Range: -58 to 2822°F (-50 to 1550°C) Accuracy: ±3.96°F (±2.2°C) ±thermocouple probe accuracy Resolution: 0.15°F (0.08°C) |
S | Range: -58 to 3128°F (-50 to 1720°C) Accuracy: ±3.96°F (±2.2°C) ±thermocouple probe accuracy Resolution: 0.15°F (0.08°C) |
B | Range: 1022 to 3308°F (550 to 1820°C) Accuracy: ±4.5°F (±2.5°C) ±thermocouple probe accuracy Resolution: 0.18°F (0.1°C) |
N | Range: -436 to 2372°F (-260 to 1300°C) Accuracy: ±1.8°F (±1.0°C) ±thermocouple probe accuracy Resolution: 0.11°F (0.06°C) |
Internal 10K Thermistor (Temperature) | |
Logging Range | -4 to 158°F (-20 to 70°C) |
Accuracy | ±0.38°F from 32 to 122°F (±0.21°C from 0 to 50°C) |
Resolution | 0.04°F at 77°F (0.024°C at 25°C) |
Drift | 0.18°F (<0.1°C) per year |
Logger | |
Operating Range | Logging: -4 to 158°F (-20 to 70°C); 0 to 95% RH (non-condensing); logger accuracy from 32 to 122°F (0 to 50°C) Launch/Readout: 32 to 122°F (0 to 50°C) per USB specification |
Resolution | 22-bit |
Logging | Rate: 1 second to 18 hours, 12 minutes, 15 seconds Modes: Normal, Burst or Statistics |
Modes | Memory: Wrap when full or stop when full Start: Immediately, push button, date and time or next interval Stop: When memory full, push button, or date and time Restart: Push button |
Time Accuracy | ±1 minute per month at 77°F (25°C) |
Battery | Life: 1 year, typical with logging rate of 1 minute and sampling interval of 15 seconds or greater Type: 1 x 3 V CR2032 lithium battery |
Environmental Rating | IP50 |
Dimensions | 1.44 x 2.34 x 0.6" (3.66 x 5.94 x 1.52 cm) |
Weight | 1.06 oz (30 g) |
Cliquer sur une catégorie pour voir une sélection d'accessoires compatible avec le Onset HOBO UX100-014M Thermocouple Data Logger, single-channel.