Onset HOBO T-ACT-0750-250 Accu-CT Current Transformer, 250 A/333 mV

Modèle: T-ACT-0750-250

Onset HOBO T-ACT-0750-250 Accu-CT Current Transformer, 250 A/333 mV

Modèle: T-ACT-0750-250

Revenue grade, split-core current transformer offers outstanding linearity and phase angle accuracy with a unique one-handed opening and closing mechanism.

Revenue grade, split-core current transformer offers outstanding linearity and phase angle accuracy with a unique one-handed opening and closing mechanism.

Prix régulier $163.00 CAD
Disponibilité 6 à 7 semaines
Quantité

Traceable Calibration Certificate Icon

Certificat d’étalonnage de traçabilité pour votre T-ACT-0750-250 Accu-CT Current Transformer

Traceable Calibration Certificate Icon

Certificat d’étalonnage de traçabilité pour votre T-ACT-0750-250 Accu-CT Current Transformer

Onset HOBO T-ACT-0750-250 Offers

For use with HOBO H22, U30, and RX3000 Series Data Loggers.

Features

  • Unprecedented Linearity
  • Window Opening 0.75 Inch
  • The Accu-CT revenue grade, split-core current transformer offers outstanding linearity and phase angle accuracy with a unique one-handed opening and closing mechanism.
  • Safe: burden resistor built-in, 333 mVac voltage output at rated full scale current, no shorting blocks needed
  • IEEE C57.13 and IEC 60044-1 accuracy: over full temperature range and down to 1% of rated current
  • Exceptionally low phase angle error: essential for accurate power and energy measurements
  • Glove-friendly: easy to open and install with one hand while wearing safety gloves
  • Approvals: UL recognized, CE mark, RoHS

Onset HOBO T-ACT-0750-250 Specifications

Accuracy +/-0.75% from 1% to 120% of rated primary current
Phase angle +/- 0.5 degrees (30 minutes) from 1% to 120% of rated current
Accuracy standards IEEE C57.13 class 1.2 and IEC 60044-1 class 1.0
Primary rating 5 to 250 Amps, 600 Vac, 60 Hz nominal
Output 333.33 mVac at rated current
Operating temperature range -30C to 55C
Operating humidity range 0 to 95% RH non-condensing
Safe integral burden resistor, no shorting block needed, unlessotherwise noted
Standard lead length Standard lead length
Cliquer ici pour toutes les spécifications du Onset HOBO T-ACT-0750-250

Le Onset HOBO T-ACT-0750-250 comprend

  • Onset HOBO T-ACT-0750-250 Accu-CT Current Transformer, 250 A/333 mV

Poser une question sur le Onset HOBO T-ACT-0750-250 Accu-CT Current Transformer, 250 A/333 mV

Onset HOBO T-ACT-0750-250 Offers

For use with HOBO H22, U30, and RX3000 Series Data Loggers.

Features

  • Unprecedented Linearity
  • Window Opening 0.75 Inch
  • The Accu-CT revenue grade, split-core current transformer offers outstanding linearity and phase angle accuracy with a unique one-handed opening and closing mechanism.
  • Safe: burden resistor built-in, 333 mVac voltage output at rated full scale current, no shorting blocks needed
  • IEEE C57.13 and IEC 60044-1 accuracy: over full temperature range and down to 1% of rated current
  • Exceptionally low phase angle error: essential for accurate power and energy measurements
  • Glove-friendly: easy to open and install with one hand while wearing safety gloves
  • Approvals: UL recognized, CE mark, RoHS

Onset HOBO T-ACT-0750-250 Specifications

Accuracy +/-0.75% from 1% to 120% of rated primary current
Phase angle +/- 0.5 degrees (30 minutes) from 1% to 120% of rated current
Accuracy standards IEEE C57.13 class 1.2 and IEC 60044-1 class 1.0
Primary rating 5 to 250 Amps, 600 Vac, 60 Hz nominal
Output 333.33 mVac at rated current
Operating temperature range -30C to 55C
Operating humidity range 0 to 95% RH non-condensing
Safe integral burden resistor, no shorting block needed, unlessotherwise noted
Standard lead length Standard lead length
Cliquer ici pour toutes les spécifications du Onset HOBO T-ACT-0750-250

Le Onset HOBO T-ACT-0750-250 comprend

  • Onset HOBO T-ACT-0750-250 Accu-CT Current Transformer, 250 A/333 mV

Poser une question sur le Onset HOBO T-ACT-0750-250 Accu-CT Current Transformer, 250 A/333 mV

Plus de produits Onset HOBO