Conveniently measure and record CO2 in buildings and other non-condensing environments with this wireless carbon dioxide/temperature/RH data logger. With Bluetooth Low Energy technology, this data logger wirelessly transfers data over a 100' (30 m) range.
Conveniently measure and record CO2 in buildings and other non-condensing environments with this wireless carbon dioxide/temperature/RH data logger. With Bluetooth Low Energy technology, this data logger wirelessly transfers data over a 100' (30 m) range.
Measures and transmits CO2data wirelessly to mobile devices or Windows computers via Bluetooth Low Energy (BLE) technology. This self-contained wireless data logger works with a mobile device or Windows computer and the HOBOconnect app, so you can configure the logger and read out data over a 100' range, with no other dedicated equipment required. Using the free app, you can also view data in graphs, check the operational status of loggers, configure alarm notifications, and share data files.
Note: This data logger requires a compatible mobile device or Windows computer and the HOBOconnect app.
Caractéristiques
In what environment does this data logger operate?
Supported measurements
Download the Mobile App
| Temperature Sensor | |
| Range | 32 to 122°F (0 to 50°C) |
| Drift | <0.18°F (0.1°C) per year |
| RH Sensor | |
| Drift | <1% per year typical |
| CO2 Sensor | |
| Non-Linearity | <1% of FS |
| Temperature Sensor | |
| Accuracy | ±0.38°F from 32 to 122°F (±0.21°C from 0 to 50°C) |
| Resolution | 0.04°F at 77°F (0.024°C at 25°C) |
| RH Sensor | |
| Range | 1 to 70% RH when CO2 sensor is enabled (non-condensing) 1 to 90% RH when CO2 sensor is disabled (non-condensing) |
| Accuracy | ±2% from 20 to 80% typical at 77°F (25°C) |
| Resolution | 0.01% at 77°F (25°C) |
| CO2 Sensor | |
| Range | 0 to 5000 ppm |
| Accuracy | ±50 ppm ±5% of reading at 77°F (25°C), less than 90% RH non-condensing and 1013 mbar |
| Warm-up Time | 15 seconds |
| Calibration | Auto or manual to 400 ppm |
| Pressure Dependence | 0.13% of reading per mm Hg (corrected via user input for elevation/altitude) |
| Pressure Range | Operating: 950 to 1050 mbar (use Altitude Compensation for outside of this range) Compensated: -1000 to 18,000' (-305 to 5486 m) |
| Response Time | |
| Temperature | 12 minutes to 90% in airflow of 1 m/s (2.2 mph) |
| RH | 1 minute to 90% in airflow of 1 m/s (2.2 mph) |
| CO2 | 1 minute to 90% in airflow of 1 m/s (2.2 mph) |
| Logger | |
| Radio Power | 1 mW (0 dBm) |
| Transmission Range | Approximately 100' (30.5 m) line-of-sight |
| Operating Range | 32 to 122°F (0 to 50°C); 0 to 95% RH (non-condensing) |
| Logging Rate | 1 second to 18 hours |
| Modes | Logging: Fixed interval (normal, statistics) or burst Memory: Wrap when full or stop when full Start: Immediate, push button, date and time, or next interval Stop: When memory full, push button, date and time, or after a set logging period |
| Time Accuracy | ±1 minute per month at 77°F (25°C) |
| Battery | Life: 6 months, typical with logging and sampling intervals of 5 minutes or slower 6 months or less with logging and sampling intervals faster than 5 minutes while logging CO2. Entering burst logging mode will impact battery life. With app use, battery life can be reduced by remaining connected, excessive readouts, audible alarms, and paging. Visual/audible alarms and other events can have a marginal impact on battery life. Type: 4 x AA 1.5 V batteries (user replaceable) or USB power source (5 V DC, 2 Watts) |
| Environmental Rating | IP50 |
| Dimensions | 3 x 5.1 x 1.88" (7.62 x 12.95 x 4.78 cm) |
| Weight | 9.43 oz (267.4 g) |
Cliquer sur une catégorie pour voir une sélection d'accessoires compatible avec le Onset HOBO MX1102A Wireless Carbon Dioxide/Temperature/RH Data Logger.
| Temperature Sensor | |
| Range | 32 to 122°F (0 to 50°C) |
| Drift | <0.18°F (0.1°C) per year |
| RH Sensor | |
| Drift | <1% per year typical |
| CO2 Sensor | |
| Non-Linearity | <1% of FS |
| Temperature Sensor | |
| Accuracy | ±0.38°F from 32 to 122°F (±0.21°C from 0 to 50°C) |
| Resolution | 0.04°F at 77°F (0.024°C at 25°C) |
| RH Sensor | |
| Range | 1 to 70% RH when CO2 sensor is enabled (non-condensing) 1 to 90% RH when CO2 sensor is disabled (non-condensing) |
| Accuracy | ±2% from 20 to 80% typical at 77°F (25°C) |
| Resolution | 0.01% at 77°F (25°C) |
| CO2 Sensor | |
| Range | 0 to 5000 ppm |
| Accuracy | ±50 ppm ±5% of reading at 77°F (25°C), less than 90% RH non-condensing and 1013 mbar |
| Warm-up Time | 15 seconds |
| Calibration | Auto or manual to 400 ppm |
| Pressure Dependence | 0.13% of reading per mm Hg (corrected via user input for elevation/altitude) |
| Pressure Range | Operating: 950 to 1050 mbar (use Altitude Compensation for outside of this range) Compensated: -1000 to 18,000' (-305 to 5486 m) |
| Response Time | |
| Temperature | 12 minutes to 90% in airflow of 1 m/s (2.2 mph) |
| RH | 1 minute to 90% in airflow of 1 m/s (2.2 mph) |
| CO2 | 1 minute to 90% in airflow of 1 m/s (2.2 mph) |
| Logger | |
| Radio Power | 1 mW (0 dBm) |
| Transmission Range | Approximately 100' (30.5 m) line-of-sight |
| Operating Range | 32 to 122°F (0 to 50°C); 0 to 95% RH (non-condensing) |
| Logging Rate | 1 second to 18 hours |
| Modes | Logging: Fixed interval (normal, statistics) or burst Memory: Wrap when full or stop when full Start: Immediate, push button, date and time, or next interval Stop: When memory full, push button, date and time, or after a set logging period |
| Time Accuracy | ±1 minute per month at 77°F (25°C) |
| Battery | Life: 6 months, typical with logging and sampling intervals of 5 minutes or slower 6 months or less with logging and sampling intervals faster than 5 minutes while logging CO2. Entering burst logging mode will impact battery life. With app use, battery life can be reduced by remaining connected, excessive readouts, audible alarms, and paging. Visual/audible alarms and other events can have a marginal impact on battery life. Type: 4 x AA 1.5 V batteries (user replaceable) or USB power source (5 V DC, 2 Watts) |
| Environmental Rating | IP50 |
| Dimensions | 3 x 5.1 x 1.88" (7.62 x 12.95 x 4.78 cm) |
| Weight | 9.43 oz (267.4 g) |
Cliquer sur une catégorie pour voir une sélection d'accessoires compatible avec le Onset HOBO MX1102A Wireless Carbon Dioxide/Temperature/RH Data Logger.