OAKTON WD-35812-34 Double-Junction Epoxy-Body Perchlorate ClO4 Ion-Selective Electrode

Modèle: WD-35812-34

OAKTON WD-35812-34 Double-Junction Epoxy-Body Perchlorate ClO4 Ion-Selective Electrode

Modèle: WD-35812-34

This ion-selective electrode can be used in a variety of applications. Utilize the refillable design to prolong the electrode's life.

This ion-selective electrode can be used in a variety of applications. Utilize the refillable design to prolong the electrode's life.

Discontinué!

Ce produit a été discontinué et n’est plus disponible. Il n’y a pas de produit de remplacement direct. Ne vous inquiétez pas, nous avons quelques options pour vous aider à trouver ce dont vous avez besoin:

Visitez notre catégorie Électrodes spécialisées pour trouver des produits similaires.

Ou nous ferons une recherche et vous aiderons à trouver ce dont vous avez besoin:


OAKTON WD-35812-34 Offers



Quickly and accurately measure perchlorate ions in a solution with the OAKTON WD-35812-34 Double-Junction Epoxy-Body Perchlorate ClO4 Ion-Selective Electrode. It's compatible with a wide range of ion meters, as well as other meters with a 0.1 mV resolution, for added convenience.

Features

  • For use with Ion 700 benchtop meters, Ion 2700 benchtop meters, PC 2700 benchtop meters, Ion 6+ handheld meters and other ion meters (sold separately)
  • Also compatible with meters that have a 0.1 mV resolution
  • Features a typical response time of 20 to 30 seconds
  • Refillable design helps promote electrode longevity

Applications

  • Explosives and Solid Propellants

OAKTON WD-35812-34 Specifications


Typical Response Time20 to 30 seconds
Electrode TypePolymer membrane
JunctionDouble
Body HousingEpoxy
RefillableYes
Range98,000 to 0.7 ppm
CompatibilityIon 700 benchtop meters, Ion 2700 benchtop meters, PC 2700 benchtop meters, Ion 6+ handheld meters and other ion meters

What's included with the OAKTON WD-35812-34


  • Double-Junction Epoxy-Body Perchlorate ClO4 Ion-Selective Electrode
  • 0.51 oz (15 mL) of electrolyte
  • Filling pipette
  • Replacement membrane

Poser une question sur le OAKTON WD-35812-34 Double-Junction Epoxy-Body Perchlorate ClO4 Ion-Selective Electrode

OAKTON WD-35812-34 Offers



Quickly and accurately measure perchlorate ions in a solution with the OAKTON WD-35812-34 Double-Junction Epoxy-Body Perchlorate ClO4 Ion-Selective Electrode. It's compatible with a wide range of ion meters, as well as other meters with a 0.1 mV resolution, for added convenience.

Features

  • For use with Ion 700 benchtop meters, Ion 2700 benchtop meters, PC 2700 benchtop meters, Ion 6+ handheld meters and other ion meters (sold separately)
  • Also compatible with meters that have a 0.1 mV resolution
  • Features a typical response time of 20 to 30 seconds
  • Refillable design helps promote electrode longevity

Applications

  • Explosives and Solid Propellants

OAKTON WD-35812-34 Specifications


Typical Response Time20 to 30 seconds
Electrode TypePolymer membrane
JunctionDouble
Body HousingEpoxy
RefillableYes
Range98,000 to 0.7 ppm
CompatibilityIon 700 benchtop meters, Ion 2700 benchtop meters, PC 2700 benchtop meters, Ion 6+ handheld meters and other ion meters

What's included with the OAKTON WD-35812-34


  • Double-Junction Epoxy-Body Perchlorate ClO4 Ion-Selective Electrode
  • 0.51 oz (15 mL) of electrolyte
  • Filling pipette
  • Replacement membrane

Poser une question sur le OAKTON WD-35812-34 Double-Junction Epoxy-Body Perchlorate ClO4 Ion-Selective Electrode

Plus de produits OAKTON