MRU 410074US2 OPTIMA7 Biogas Analyzer with Bluetooth

Modèle: 410074US2

MRU 410074US2 OPTIMA7 Biogas Analyzer with Bluetooth

Modèle: 410074US2

The analyzer is designed for measuring emissions. It is designed to focus on 7 common gases.

The analyzer is designed for measuring emissions. It is designed to focus on 7 common gases.

Discontinué!

Ce produit a été discontinué et n’est plus disponible.
Voici le produit de remplacement direct :

MRU Optimax Biogas Analyseur de Gaz Portable, CH<sub>4</sub>/CO<sub>2</sub>/O<sub>2</sub>-

MRU Optimax Biogas Analyseur de Gaz Portable, CH4/CO2/O2

Modèle: 420074US2

Idéal pour les sites d'enfouissement et les digesteurs anaérobies, cet analyseur de gaz portable mesure le méthane, le dioxyde de carbone, l'oxygène, la pression, le débit et la température. De plus, cet analyseur peut également être équipé pour le réglage des moteurs WTE, que ce soit au biogaz ou au gaz naturel, afin de mesurer le monoxyde de carbone et l'oxyde d'azote.


Accessoires recommandées


MRU 410074US2 offre

The MRU 410074US2 OPTIMA7 Biogas Analyzer with Bluetooth improves monitoring of emissions and exhausts. The analyzer is calibrated for 7 common gases in emissions to provide greater reliability. It is designed with an intuitive software menu to allow the user to adjust the settings directly from the display.

Caractéristiques

  • Calibrated to operate on 7 types of gas
  • Designed to monitor emission of combustion and industrial processes
  • Integrated menu and clear display for ease of operation
  • Uses Bluetooth® for faster data transfer and remote control

Spécifications pour le MRU 410074US2

Measuring Components
Methane (MH4) Measuring method: NDIR
Measuring range: 0 to 100%
Resolution: 0.1%
Repeatability: ±0.3% or 3% reading
Carbon Dioxide (CO2) Measuring method: NDIR
Measuring range: 0 to 100%
Resolution: 0.1%
Repeatability: ±0.3% or 3% reading
Hydrogen Sulfide (H2S) Measuring method: Electro-chemical
Measuring range: 0 to 2000 ppm/5000 ppm
Resolution: 1 ppm
Repeatability: ±5 ppm or 5% (0 to 500 ppm), 10% (>500 ppm) reading
Oxygen (O2) Long Life Measuring method: Electro-chemical
Measuring range: 0 to 25%
Resolution: 0.01%
Repeatability: ±0.2% absolute
Hydrogen (H2) Measuring method: Electro-chemical
Measuring range: 0 to 1000 ppm/2000 ppm
Resolution: 1 ppm
Repeatability: ±5 ppm or 5% (0 to 500 ppm), 10% (>500 ppm) reading
Nitrogen (N2) Measuring method: Calculated
Measuring range: 0 to 100%
Resolution: 0.1%
Calorific Value (Hu) Measuring method: Calculated
Measuring range: 0 to 36 MJ/m3
Resolution: 0.01 MJ/m3
Carbon Monoxide (CO) Measuring method: Electro-chemical
Measuring range: 0 to 10,000/20,000 ppm
Resolution: 1 ppm
Repeatability: ±10 ppm or 5% (0 to 4000 ppm), 10% (>4000 ppm) reading
Nitric Monoxide (NO) Measuring method: Electro-chemical
Measuring range: 0 to 1000/5000 ppm
Resolution: 1 ppm
Repeatability: ±5 ppm or 5% (0 to 1000 ppm), 10% (>1000 ppm) reading
Nitric Dioxide (NO2) Measuring method: Electro-chemical
Measuring range: 0 to 200/1000 ppm
Resolution: 1 ppm
Repeatability: ±5 ppm or 5% (0 to 200 ppm), 10% (>200 ppm) reading
Nitrogen Oxide (NOx) Measuring method: Calculated
Measuring range: 0 to 5000 ppm
Resolution: 1 ppm
Repeatability: ±5 ppm or 5% (0 to 1000 ppm), 10% (>1000 ppm) reading
Sulfur Dioxide (SO2) Measuring range: 0 to 2000 ppm/5000 ppm
Resolution: 1 ppm
Repeatability: ±10 ppm or 5% (0 to 2000 ppm), 10% (>5000 ppm) reading
Hydrogen Sulfide Dioxide (H2S) Measuring range: 0 to 500 ppm/2000 ppm
Resolution: 1 ppm
Repeatability: ±5 ppm or 5% (0 to 500 ppm), 10% (>5000 ppm) reading
Gas Flow Velocity Measuring method: S-type probe
Measuring range: 1 to 100 m/s
Resolution: 0.1 m/s
Repeatability: ±0.2 m/s (2 to 10 m/s), ±0.5% (>10 m/s)
Flow Rate Measuring method: Calculated
Measuring range: 0.1 to 6000 m3/s
Resolution: 0.1 m3/s
Repeatability: User settable cross section area
Differential Temperature Measuring method: NiCrNi
Measuring range: -40 to 2192°F (-40 to 1200°C)
Resolution: 1°F
Repeatability: ±4°F (2°C), 0.5% reading
Differential Pressure Measuring method: Piezo
Measuring range: ±120 inH2O (300 hPa)
Resolution: 0.01 hPa
Repeatability: ±0.01 inH2O (0.03 hPa), 1% reading
Calculated Values (Fuel Type Depending)
Carbon Dioxide (CO2) Range: 0 to 20%
Accuracy: ±0.3 vol. - % abs.
General Specifications
Operating Conditions Temperature: 41°F to 113°F (5 to 45°C) max. 95% RH, none condensing
Storage: 4°F to 122°F (-20°C to 50°C)
Data Storage Up to 16,000 measurements
Interfaces SD card reader, USB, infrared, Bluetooth
Power Supply Internal: Lithium-Ion battery, 15 hours operation time
Mains: Wall plug unit 100 to 240 V AC, 50 to 60 Hz, 5 V DC, 1.2 A
Protection Class IP30
Cerfication TUV ByRgG 280, VDI 4206-1, EN 50379
Dimensions 2.05 x 4.33 x 8.86" (52 x 110 x 225 mm)
Weight Approximately 1.7 lbs (750 g)

Le MRU 410074US2 comprend

  • MRU 410074US2 OPTIMA7 Biogas Analyzer with Bluetooth

Cliquer sur une catégorie pour voir une sélection d'accessoires compatible avec le MRU 410074US2 OPTIMA7 Biogas Analyzer with Bluetooth.

MRU 62931 ABS Transport case with large compartment 62931
The case protects equipment during travel. It features a large compartment for better storage.




MRU 63677 IR Printer 63677
The printer improves recording capacity during operation. It is designed to work with manometers and gas analyzers.




MRU 59465 Printer Paper Rolls, 5-pack 59465
The paper provides a convenient space to record data. It offers plenty of room for countless operations.




MRU 65670 Stainless Steel Mounting Fitting, 0.47", male 65670
The fitting improves the stability of probes during operation. It is designed for stationary monitoring.




Poser une question sur le MRU 410074US2 OPTIMA7 Biogas Analyzer with Bluetooth

MRU 410074US2 offre

The MRU 410074US2 OPTIMA7 Biogas Analyzer with Bluetooth improves monitoring of emissions and exhausts. The analyzer is calibrated for 7 common gases in emissions to provide greater reliability. It is designed with an intuitive software menu to allow the user to adjust the settings directly from the display.

Caractéristiques

  • Calibrated to operate on 7 types of gas
  • Designed to monitor emission of combustion and industrial processes
  • Integrated menu and clear display for ease of operation
  • Uses Bluetooth® for faster data transfer and remote control

Spécifications pour le MRU 410074US2

Measuring Components
Methane (MH4) Measuring method: NDIR
Measuring range: 0 to 100%
Resolution: 0.1%
Repeatability: ±0.3% or 3% reading
Carbon Dioxide (CO2) Measuring method: NDIR
Measuring range: 0 to 100%
Resolution: 0.1%
Repeatability: ±0.3% or 3% reading
Hydrogen Sulfide (H2S) Measuring method: Electro-chemical
Measuring range: 0 to 2000 ppm/5000 ppm
Resolution: 1 ppm
Repeatability: ±5 ppm or 5% (0 to 500 ppm), 10% (>500 ppm) reading
Oxygen (O2) Long Life Measuring method: Electro-chemical
Measuring range: 0 to 25%
Resolution: 0.01%
Repeatability: ±0.2% absolute
Hydrogen (H2) Measuring method: Electro-chemical
Measuring range: 0 to 1000 ppm/2000 ppm
Resolution: 1 ppm
Repeatability: ±5 ppm or 5% (0 to 500 ppm), 10% (>500 ppm) reading
Nitrogen (N2) Measuring method: Calculated
Measuring range: 0 to 100%
Resolution: 0.1%
Calorific Value (Hu) Measuring method: Calculated
Measuring range: 0 to 36 MJ/m3
Resolution: 0.01 MJ/m3
Carbon Monoxide (CO) Measuring method: Electro-chemical
Measuring range: 0 to 10,000/20,000 ppm
Resolution: 1 ppm
Repeatability: ±10 ppm or 5% (0 to 4000 ppm), 10% (>4000 ppm) reading
Nitric Monoxide (NO) Measuring method: Electro-chemical
Measuring range: 0 to 1000/5000 ppm
Resolution: 1 ppm
Repeatability: ±5 ppm or 5% (0 to 1000 ppm), 10% (>1000 ppm) reading
Nitric Dioxide (NO2) Measuring method: Electro-chemical
Measuring range: 0 to 200/1000 ppm
Resolution: 1 ppm
Repeatability: ±5 ppm or 5% (0 to 200 ppm), 10% (>200 ppm) reading
Nitrogen Oxide (NOx) Measuring method: Calculated
Measuring range: 0 to 5000 ppm
Resolution: 1 ppm
Repeatability: ±5 ppm or 5% (0 to 1000 ppm), 10% (>1000 ppm) reading
Sulfur Dioxide (SO2) Measuring range: 0 to 2000 ppm/5000 ppm
Resolution: 1 ppm
Repeatability: ±10 ppm or 5% (0 to 2000 ppm), 10% (>5000 ppm) reading
Hydrogen Sulfide Dioxide (H2S) Measuring range: 0 to 500 ppm/2000 ppm
Resolution: 1 ppm
Repeatability: ±5 ppm or 5% (0 to 500 ppm), 10% (>5000 ppm) reading
Gas Flow Velocity Measuring method: S-type probe
Measuring range: 1 to 100 m/s
Resolution: 0.1 m/s
Repeatability: ±0.2 m/s (2 to 10 m/s), ±0.5% (>10 m/s)
Flow Rate Measuring method: Calculated
Measuring range: 0.1 to 6000 m3/s
Resolution: 0.1 m3/s
Repeatability: User settable cross section area
Differential Temperature Measuring method: NiCrNi
Measuring range: -40 to 2192°F (-40 to 1200°C)
Resolution: 1°F
Repeatability: ±4°F (2°C), 0.5% reading
Differential Pressure Measuring method: Piezo
Measuring range: ±120 inH2O (300 hPa)
Resolution: 0.01 hPa
Repeatability: ±0.01 inH2O (0.03 hPa), 1% reading
Calculated Values (Fuel Type Depending)
Carbon Dioxide (CO2) Range: 0 to 20%
Accuracy: ±0.3 vol. - % abs.
General Specifications
Operating Conditions Temperature: 41°F to 113°F (5 to 45°C) max. 95% RH, none condensing
Storage: 4°F to 122°F (-20°C to 50°C)
Data Storage Up to 16,000 measurements
Interfaces SD card reader, USB, infrared, Bluetooth
Power Supply Internal: Lithium-Ion battery, 15 hours operation time
Mains: Wall plug unit 100 to 240 V AC, 50 to 60 Hz, 5 V DC, 1.2 A
Protection Class IP30
Cerfication TUV ByRgG 280, VDI 4206-1, EN 50379
Dimensions 2.05 x 4.33 x 8.86" (52 x 110 x 225 mm)
Weight Approximately 1.7 lbs (750 g)

Le MRU 410074US2 comprend

  • MRU 410074US2 OPTIMA7 Biogas Analyzer with Bluetooth

Cliquer sur une catégorie pour voir une sélection d'accessoires compatible avec le MRU 410074US2 OPTIMA7 Biogas Analyzer with Bluetooth.

MRU 62931 ABS Transport case with large compartment 62931
The case protects equipment during travel. It features a large compartment for better storage.




MRU 63677 IR Printer 63677
The printer improves recording capacity during operation. It is designed to work with manometers and gas analyzers.




MRU 59465 Printer Paper Rolls, 5-pack 59465
The paper provides a convenient space to record data. It offers plenty of room for countless operations.




MRU 65670 Stainless Steel Mounting Fitting, 0.47", male 65670
The fitting improves the stability of probes during operation. It is designed for stationary monitoring.




Poser une question sur le MRU 410074US2 OPTIMA7 Biogas Analyzer with Bluetooth

Plus de produits MRU