MJK 295911 mA-Bus Converter, wide field cabinet with display, I/O- 2AI / 3DI

Modèle: 295911 | No. de commande: MJK295911

MJK 295911 mA-Bus Converter, wide field cabinet with display, I/O- 2AI / 3DI

Modèle: 295911 | No. de commande: MJK295911

Used when a measured value from a transmitter with an analog mA signal is to be shown on a display, the mA-Bus converter translates any mA signal to Modbus and can be used together with the transmitter series for flow, dissolved oxygen, turbidity, etc.

Used when a measured value from a transmitter with an analog mA signal is to be shown on a display, the mA-Bus converter translates any mA signal to Modbus and can be used together with the transmitter series for flow, dissolved oxygen, turbidity, etc.

Discontinué!

Ce produit a été discontinué et n’est plus disponible. Il n’y a pas de produit de remplacement direct. Ne vous inquiétez pas, nous avons quelques options pour vous aider à trouver ce dont vous avez besoin:

Visitez notre catégorie Convertisseurs pour trouver des produits similaires.

Ou nous ferons une recherche et vous aiderons à trouver ce dont vous avez besoin:


MJK 295911 Offers

The mA-Bus converter is made of glass-reinforced polycarbonate.

Applications

  • Well water supply systems
  • Booster stations on the water supply system

MJK 295911 Specifications

Inputs I/O’s - 3DI / 2AI
Analog Inputs 2 pcs. AI galvanic separated, 4 to 20 mA
Accuracy Better than ± 0.25 % of reading
Digital Inputs 3 pcs. DI, 10 to 30 V DC
Power Supply for I/O 1 pcs. 24 V DC, 200 mA
Communication Modbus RTU-mode, Settings, 9600 baud, 2-wire RS 485, slave
Interfaces 1 pcs. RS-485 galvanic separated for MagFlux/SuSix/Oxix or Display unit
Power Supply 115/230 V AC 50/60 Hz, &plumn;10 % or 24 V AC, 50/60 Hz &plumn; 10 %
Power Consumption Max. 10 W
Cabinet Material Glass-reinforced polycarbonate
Enclosure Rating IP 67/Nema 4x
Temperature Range -4 to 140°F (-20 to 60°C)
Weight 1 kg/2.3 lbs
CE Approvals EN 61000-6-4:2001, EN 61000-6-2:2001
Cliquer ici pour toutes les spécifications du MJK 295911

Le MJK 295911 comprend

  • MJK 295911 mA-Bus Converter, wide field cabinet with display, I/O- 2AI / 3DI

Poser une question sur le MJK 295911 mA-Bus Converter, wide field cabinet with display, I/O- 2AI / 3DI

MJK 295911 Offers

The mA-Bus converter is made of glass-reinforced polycarbonate.

Applications

  • Well water supply systems
  • Booster stations on the water supply system

MJK 295911 Specifications

Inputs I/O’s - 3DI / 2AI
Analog Inputs 2 pcs. AI galvanic separated, 4 to 20 mA
Accuracy Better than ± 0.25 % of reading
Digital Inputs 3 pcs. DI, 10 to 30 V DC
Power Supply for I/O 1 pcs. 24 V DC, 200 mA
Communication Modbus RTU-mode, Settings, 9600 baud, 2-wire RS 485, slave
Interfaces 1 pcs. RS-485 galvanic separated for MagFlux/SuSix/Oxix or Display unit
Power Supply 115/230 V AC 50/60 Hz, &plumn;10 % or 24 V AC, 50/60 Hz &plumn; 10 %
Power Consumption Max. 10 W
Cabinet Material Glass-reinforced polycarbonate
Enclosure Rating IP 67/Nema 4x
Temperature Range -4 to 140°F (-20 to 60°C)
Weight 1 kg/2.3 lbs
CE Approvals EN 61000-6-4:2001, EN 61000-6-2:2001