Industry best guard terminal accuracy. Compact and lightweight for easy transport and use. This value added kit includes the Megger MIT420-EN Insulation Tester for FREE.
Industry best guard terminal accuracy. Compact and lightweight for easy transport and use. This value added kit includes the Megger MIT420-EN Insulation Tester for FREE.
Discontinué!
Ce produit a été discontinué et n’est plus disponible.
Voici le produit de remplacement direct :
Purchase a MEGGER MIT1025 Insulation resistance tester and receive a MEGGER MIT420 Insulation/Continuity tester for FREE.
Megger MIT1025 Megohmmeter
The Megger MIT1025 10 kV Insulation Resistance Tester meets IP65 standards and can take measurements when connected to line power/mains with a dead battery.
Applications
Megger MIT420 Insulation/Continuity Tester
Applications
| Insulation Range, Analog | 100kW to 10TW |
| Insulation Range, Digital | 10kW to 20TW |
| Test Voltages | 500V, 1000V, 2500V, 5000V, and 10,000V |
| User Defined Test Voltages | 100V to 1kV in 10V steps 1kV to 5kV in 25V steps 5kV to 10kV in 25V steps |
| Accuracy | ±5% to 2TΩ, ±20% to 20TΩ |
| Voltage Output Accuracy | +4% -0% ±10V of nominal test voltage at 1GW load |
| Voltmeter Range | 30 to 660V AC/DC, 50/60Hz |
| Voltmeter Accuracy | ±3% ±3V |
| Frequency Range | 45 to 65Hz |
| Short Circuit Current | 3mA nominal, max. power on all loads outperforming many 5mA testers |
| Insulation Alarm | 100kΩ to 1GΩ |
| Current Range | 0.01nA to 6mA |
| Current Accuracy | ±5% ±0.2 nA at all voltages |
| Capacitance Range (above 500V) | 10nF to 25µF (dependent on measurement voltage) |
| Capacitance Accuracy | ±10% ±5nF |
| Capacitor Charge | <5s per µF at 3mA to 10kV</td> |
| Capacitor Discharge | <500 ms/µF to discharge from 10,000V to 50V</td> |
Industry best guard terminal accuracy. Compact and lightweight for easy transport and use.
Analog/Digital Insulation Tester. 50/100/250V/500V/1000V, 600V CAT IV, PI & DAR, Result Storage/Recall.
| Insulation Range, Analog | 100kW to 10TW |
| Insulation Range, Digital | 10kW to 20TW |
| Test Voltages | 500V, 1000V, 2500V, 5000V, and 10,000V |
| User Defined Test Voltages | 100V to 1kV in 10V steps 1kV to 5kV in 25V steps 5kV to 10kV in 25V steps |
| Accuracy | ±5% to 2TΩ, ±20% to 20TΩ |
| Voltage Output Accuracy | +4% -0% ±10V of nominal test voltage at 1GW load |
| Voltmeter Range | 30 to 660V AC/DC, 50/60Hz |
| Voltmeter Accuracy | ±3% ±3V |
| Frequency Range | 45 to 65Hz |
| Short Circuit Current | 3mA nominal, max. power on all loads outperforming many 5mA testers |
| Insulation Alarm | 100kΩ to 1GΩ |
| Current Range | 0.01nA to 6mA |
| Current Accuracy | ±5% ±0.2 nA at all voltages |
| Capacitance Range (above 500V) | 10nF to 25µF (dependent on measurement voltage) |
| Capacitance Accuracy | ±10% ±5nF |
| Capacitor Charge | <5s per µF at 3mA to 10kV</td> |
| Capacitor Discharge | <500 ms/µF to discharge from 10,000V to 50V</td> |
Industry best guard terminal accuracy. Compact and lightweight for easy transport and use.