With a large carrying case, this portable load bank is used for controlled battery discharge testing. It applies a stable, programmable load to accurately measure actual battery capacity and help verify system performance for maintenance and reliability planning. This has a maximum current of 100 A, and a maximum voltage of 300 V.

With a large carrying case, this portable load bank is used for controlled battery discharge testing. It applies a stable, programmable load to accurately measure actual battery capacity and help verify system performance for maintenance and reliability planning. This has a maximum current of 100 A, and a maximum voltage of 300 V.

Prix régulier $20890.00 CAD
Disponibilité 2 à 3 semaines
Quantité

Megger CS-19191-US-EN offre

Together with the optional cell voltage logger, BVM, connected directly to the TORKEL 900, it becomes a complete, stand-alone, discharge test system.

The high discharge capacity of TORKEL gives the opportunity to shorten the test time. Discharging can take place at up to 220 A, and if higher current is needed, two or more TORKEL units or extra load units, TXL, can be linked together. Tests can be conducted at constant current, constant power, constant resistance or in accordance with a pre-selected load profile.

Testing can also be carried out without disconnecting the battery from the equipment it serves. Via a DC clamp-on probe, TORKEL measures the total battery current while regulating it at a constant level. Battery systems can be plus or minus grounded or free floating

Caractéristiques

  • Batteries can be tested in service
  • Dynamic discharge technology – full power at all voltages
  • Safety in all details, e.g. detection of blocked airflow
  • Real time monitoring during test
  • Easy report function and calibration
  • Easily expandable for larger battery banks using TXL extra load units
  • Battery cell monitor control integrated in the system
  • Can be used with Lead-Acid, Ni-Cd and other battery types

Spécifications pour le Megger CS-19191-US-EN

Environment
Operating temperature 32 to 122°F (0 to 50°C)
Power derating at temperatures over 95°F (35°C)
Storage and Transport Temperature -40 to 158°F (-40 to 70°C)
Humidity 5% to 95% RH, non-condensing
Shock/Vibration/Fall Instrument Only: ETSI EN 300 019-2-7 class 7M2
Instrument in carrying case: ISTA 2A
Altitude Operating: 10000' (3000 m)
Storage: 33000' (10000 m)
Encapsulation class: IP20
Measurement
Current Measurement Display Range: 0 to 2999 A
Basic Inaccuracy: ±(0.5% of reading +0.1 A)
Resolution: 0.1 A
Internal current measurement Range: 0 to 110 A
Clamp-on Probe Input Range: 0 to 1000 mV DC
mV/A-ratio: 0.30 to 100.00 mV/A
Input impedence: >1 MΩ
Voltage Measurement Range: 0 to 500 V DC
Inaccuracy: ±(0.5% of reading +0.1 VDC)
Resolution: 0.1 V
Sample rate: 10 Hz, values are saved when change is >10mV
Time Measurement Inaccuracy: ±0.1% of reading ±1 digit
Load
Load patterns Constant current
Constant power
Constant resistance
Current or power profile
Battery Voltage 7.5 V3) to 300 V1) / 500 V2)
Power 15 kW (max)
Constant I Range: 0 to 110.0 A
Inaccuracy: ±(0.5% +0.2 A)
Resolution: 0.1 A
Ripple: max 0.5 A peak
Constant R Range: 300 mΩ to 3 kΩ
Inaccuracy: ±1% typical
Resolution: 100 mΩ
Constant P Range: 0 to 15 kW
Inaccuracy: ±1% typical
Resolution: 10 W
Inputs
Input (+) 7.5 to 300 V
Input (-) 0 V
Input (I EXT ≤ 1 V) 1 V DC, 300 V DC to ground
Voltage sense Impedance to the current terminals is >1 MΩ
Outputs
Alarm Output (Relay Contact) 28 V DC, 8 A, 240 V AC, 8 A
Devices higher than Cat II must not be attached
TXL STOP output (Relay Contact) 250 VDC, 0.28A, 28 VDC, 8A, 250VAC, 8A
9 V DC output 9 V DC, ±7% max 100 mA
Communication Ports
Communication (BVM1 / BVM2) USB connection for BVM units
Communication (USB) USB connection for USB memory
Reports For reports connected to PC
General
Mains Voltage 100 to 240 V AC, 50/60 Hz
Power Consumption 200 W (max)
Power Interruption 40 ms (max)
Protection Thermal cut-outs, Automatic overload protection, Emergency stop button
Display 7" (17.78 cm) LCD, capacitive touch screen
Available languages Czech, English, French, German, Romanian, Russian, Spanish, Swedish
Number of test files 30 (max)
Test time 240 h (max)
Dimensions 20.5 x 12.4 x 14.7" (519 x 315 x 375 mm)
Weight Instrument: 43.0 lbs (19.5 kg)
Including Standard Carrying Case: 70.3 lbs (31.9 kg)
Including Large Carrying Case and Cables: 86.4 lbs (39.2 kg)

Le Megger CS-19191-US-EN comprend

  • High voltage substations
  • Battery Load Unit
  • Industrial environments
  • Mains Cable
  • 2 x 9.84' (3 m) Cables
  • 16' (5 m) Ground Cable
  • Large Carrying Case

Cliquer sur une catégorie pour voir une sélection d'accessoires compatible avec le Megger CS-19191-US-EN TORKEL 910 Battery Load Unit with large carrying case, 300V, 100A.

Megger GA-00552 Extension Cable Set for the TORKEL 910 series, 9.84', 25 mm² male/female, 2-pack GA-00552
A 2-pack of 9.84' (3 m) male/female extension cables for the GA-00550 used for the TORKEL 900 series units, designed to extend test lead reach while maintaining a 25 mm² conductor size for reliable connections.




Megger GA-00550 Cable Set with clamps for the TORKEL 910 series, 9.84', 25 mm² female, 110 A, 2-pack GA-00550
A heavy-duty 2-pack cable set for TORKEL 900 series units, featuring 9.84' (3 m) leads with 25 mm² female connectors and high-current clamps rated up to 110 A for secure, reliable load connections during battery testing.




Megger XA-12992 DC Clamp-On Probe for the TORKEL 900 series, 16.4', 200 A to 1 V DC, 2-pack XA-12992
A 2-pack of 16.4' (5 m) clamp-on current probes for the TORKEL 900 series, measuring up to 200 A and providing a 1 V DC output for safe, non-intrusive current monitoring during battery discharge testing.




Megger XA-12990 DC Clamp-On Probe for the TORKEL 900 series, 16.4', 1000 A to 1 V DC, 2-pack XA-12990
A 2-pack of 16.4' (5 m) clamp-on current probes for the TORKEL 900 series, measuring up to 1000 A and providing a 1 V DC output for safe, non-intrusive current monitoring during battery discharge testing.




Megger XA-12991 DC Clamp-On Probe for the TORKEL 900 series, 16.4', 1000 A to 1 V DC, 9 V input, 2-pack XA-12991
A 2-pack of 16.4' (5 m) clamp-on probes for the TORKEL 900 series, measuring up to 1000 A with a 1 V DC output and 9 V power input, enabling safe, non-intrusive high-current measurement during battery discharge testing.




Megger GD-00954 Carrying Case for the TORKEL 900 series, standard GD-00954
A standard protective case designed for the TORKEL 900 series, providing durable storage and easier transport for the unit. This provides a handle and wheels for easy transportation.




Poser une question sur le Megger CS-19191-US-EN TORKEL 910 Battery Load Unit with large carrying case, 300V, 100A

Megger CS-19191-US-EN offre

Together with the optional cell voltage logger, BVM, connected directly to the TORKEL 900, it becomes a complete, stand-alone, discharge test system.

The high discharge capacity of TORKEL gives the opportunity to shorten the test time. Discharging can take place at up to 220 A, and if higher current is needed, two or more TORKEL units or extra load units, TXL, can be linked together. Tests can be conducted at constant current, constant power, constant resistance or in accordance with a pre-selected load profile.

Testing can also be carried out without disconnecting the battery from the equipment it serves. Via a DC clamp-on probe, TORKEL measures the total battery current while regulating it at a constant level. Battery systems can be plus or minus grounded or free floating

Caractéristiques

  • Batteries can be tested in service
  • Dynamic discharge technology – full power at all voltages
  • Safety in all details, e.g. detection of blocked airflow
  • Real time monitoring during test
  • Easy report function and calibration
  • Easily expandable for larger battery banks using TXL extra load units
  • Battery cell monitor control integrated in the system
  • Can be used with Lead-Acid, Ni-Cd and other battery types

Spécifications pour le Megger CS-19191-US-EN

Environment
Operating temperature 32 to 122°F (0 to 50°C)
Power derating at temperatures over 95°F (35°C)
Storage and Transport Temperature -40 to 158°F (-40 to 70°C)
Humidity 5% to 95% RH, non-condensing
Shock/Vibration/Fall Instrument Only: ETSI EN 300 019-2-7 class 7M2
Instrument in carrying case: ISTA 2A
Altitude Operating: 10000' (3000 m)
Storage: 33000' (10000 m)
Encapsulation class: IP20
Measurement
Current Measurement Display Range: 0 to 2999 A
Basic Inaccuracy: ±(0.5% of reading +0.1 A)
Resolution: 0.1 A
Internal current measurement Range: 0 to 110 A
Clamp-on Probe Input Range: 0 to 1000 mV DC
mV/A-ratio: 0.30 to 100.00 mV/A
Input impedence: >1 MΩ
Voltage Measurement Range: 0 to 500 V DC
Inaccuracy: ±(0.5% of reading +0.1 VDC)
Resolution: 0.1 V
Sample rate: 10 Hz, values are saved when change is >10mV
Time Measurement Inaccuracy: ±0.1% of reading ±1 digit
Load
Load patterns Constant current
Constant power
Constant resistance
Current or power profile
Battery Voltage 7.5 V3) to 300 V1) / 500 V2)
Power 15 kW (max)
Constant I Range: 0 to 110.0 A
Inaccuracy: ±(0.5% +0.2 A)
Resolution: 0.1 A
Ripple: max 0.5 A peak
Constant R Range: 300 mΩ to 3 kΩ
Inaccuracy: ±1% typical
Resolution: 100 mΩ
Constant P Range: 0 to 15 kW
Inaccuracy: ±1% typical
Resolution: 10 W
Inputs
Input (+) 7.5 to 300 V
Input (-) 0 V
Input (I EXT ≤ 1 V) 1 V DC, 300 V DC to ground
Voltage sense Impedance to the current terminals is >1 MΩ
Outputs
Alarm Output (Relay Contact) 28 V DC, 8 A, 240 V AC, 8 A
Devices higher than Cat II must not be attached
TXL STOP output (Relay Contact) 250 VDC, 0.28A, 28 VDC, 8A, 250VAC, 8A
9 V DC output 9 V DC, ±7% max 100 mA
Communication Ports
Communication (BVM1 / BVM2) USB connection for BVM units
Communication (USB) USB connection for USB memory
Reports For reports connected to PC
General
Mains Voltage 100 to 240 V AC, 50/60 Hz
Power Consumption 200 W (max)
Power Interruption 40 ms (max)
Protection Thermal cut-outs, Automatic overload protection, Emergency stop button
Display 7" (17.78 cm) LCD, capacitive touch screen
Available languages Czech, English, French, German, Romanian, Russian, Spanish, Swedish
Number of test files 30 (max)
Test time 240 h (max)
Dimensions 20.5 x 12.4 x 14.7" (519 x 315 x 375 mm)
Weight Instrument: 43.0 lbs (19.5 kg)
Including Standard Carrying Case: 70.3 lbs (31.9 kg)
Including Large Carrying Case and Cables: 86.4 lbs (39.2 kg)

Le Megger CS-19191-US-EN comprend

  • High voltage substations
  • Battery Load Unit
  • Industrial environments
  • Mains Cable
  • 2 x 9.84' (3 m) Cables
  • 16' (5 m) Ground Cable
  • Large Carrying Case

Cliquer sur une catégorie pour voir une sélection d'accessoires compatible avec le Megger CS-19191-US-EN TORKEL 910 Battery Load Unit with large carrying case, 300V, 100A.

Megger GA-00552 Extension Cable Set for the TORKEL 910 series, 9.84', 25 mm² male/female, 2-pack GA-00552
A 2-pack of 9.84' (3 m) male/female extension cables for the GA-00550 used for the TORKEL 900 series units, designed to extend test lead reach while maintaining a 25 mm² conductor size for reliable connections.




Megger GA-00550 Cable Set with clamps for the TORKEL 910 series, 9.84', 25 mm² female, 110 A, 2-pack GA-00550
A heavy-duty 2-pack cable set for TORKEL 900 series units, featuring 9.84' (3 m) leads with 25 mm² female connectors and high-current clamps rated up to 110 A for secure, reliable load connections during battery testing.




Megger XA-12992 DC Clamp-On Probe for the TORKEL 900 series, 16.4', 200 A to 1 V DC, 2-pack XA-12992
A 2-pack of 16.4' (5 m) clamp-on current probes for the TORKEL 900 series, measuring up to 200 A and providing a 1 V DC output for safe, non-intrusive current monitoring during battery discharge testing.




Megger XA-12990 DC Clamp-On Probe for the TORKEL 900 series, 16.4', 1000 A to 1 V DC, 2-pack XA-12990
A 2-pack of 16.4' (5 m) clamp-on current probes for the TORKEL 900 series, measuring up to 1000 A and providing a 1 V DC output for safe, non-intrusive current monitoring during battery discharge testing.




Megger XA-12991 DC Clamp-On Probe for the TORKEL 900 series, 16.4', 1000 A to 1 V DC, 9 V input, 2-pack XA-12991
A 2-pack of 16.4' (5 m) clamp-on probes for the TORKEL 900 series, measuring up to 1000 A with a 1 V DC output and 9 V power input, enabling safe, non-intrusive high-current measurement during battery discharge testing.




Megger GD-00954 Carrying Case for the TORKEL 900 series, standard GD-00954
A standard protective case designed for the TORKEL 900 series, providing durable storage and easier transport for the unit. This provides a handle and wheels for easy transportation.




Poser une question sur le Megger CS-19191-US-EN TORKEL 910 Battery Load Unit with large carrying case, 300V, 100A

Plus de produits Megger