Used for checking a battery's state of charge by measuring temperature and specific gravity. The hydrometer kit includes Anton Parr Hydrometer; 8 Channel Data Logger; Custom Carrying Case, Software CD. For use with the Megger BITE2 battery impedance tester.
Used for checking a battery's state of charge by measuring temperature and specific gravity. The hydrometer kit includes Anton Parr Hydrometer; 8 Channel Data Logger; Custom Carrying Case, Software CD. For use with the Megger BITE2 battery impedance tester.
Discontinué!
Ce produit a été discontinué et n’est plus disponible. Il n'y a aucune option de remplacement.
Nous pouvons vous aider à trouver ce dont vous avez besoin:
Features
Battery testers are used in industrial, commercial, medical, telecommunications, aircraft, power utility and military industries to detect the health of a battery. They can measure conductance, impedance, voltage, and current, among other parameters. Battery testers are designed for specific types of batteries, such as lead-acid, nickel-metal-hydride and alkaline batteries. Some testers require a load to be applied to the battery during testing, and some do not. A variety of test leads with contacts, probes, clamps, clips, and other connectors can be used to connect a battery to a tester. Since different testers measure different parameters to calculate battery health, it is important to use the same tester for consecutive tests on a single battery when analyzing changes in a battery health over time.
| Measuring Range | Density: 0 g/cm³ to 3 g/cm³ Temperature: 0 to 40°C (3 to 104°F) Viscosity: 0 mPa·s to 1000 mPa·s |
| Accuracy | Density: 0.001 g/cm³ Temperature: 0.2°C (0.4°F) |
| Repeatability, S.D. | Density: 0.0005 g/cm³ Temperature: 0.1°C (0.2°F) |
| Ambient Temperature | -10 to 50°C (14 to 122°F) |
| Sample Volume | 2 mL |
| Dimensions (L x W x H) | 140 x 138 x 27mm |
| Data Memory | 1024 Measured Results |
| Power Supply | Two 1.5 V Alkaline Batteries |
| Weight | 345g (12.2 ounces) |
| Intrinsically Safe | No |
| Measuring Range | Density: 0 g/cm³ to 3 g/cm³ Temperature: 0 to 40°C (3 to 104°F) Viscosity: 0 mPa·s to 1000 mPa·s |
| Accuracy | Density: 0.001 g/cm³ Temperature: 0.2°C (0.4°F) |
| Repeatability, S.D. | Density: 0.0005 g/cm³ Temperature: 0.1°C (0.2°F) |
| Ambient Temperature | -10 to 50°C (14 to 122°F) |
| Sample Volume | 2 mL |
| Dimensions (L x W x H) | 140 x 138 x 27mm |
| Data Memory | 1024 Measured Results |
| Power Supply | Two 1.5 V Alkaline Batteries |
| Weight | 345g (12.2 ounces) |
| Intrinsically Safe | No |