A complete utility-location system combining the RX plus receiver and TX plus transmitter for dual-frequency tracing, built-in depth-measurement functionality, and a full accessory set. Supplied in English.
A complete utility-location system combining the RX plus receiver and TX plus transmitter for dual-frequency tracing, built-in depth-measurement functionality, and a full accessory set. Supplied in English.
The Easyloc RxTx utility location system has been designed to detect and trace cable runs and pipe networks. The Easyloc RxTx is fast and simple to operate, with features designed to help you avoid potentially dangerous power cables, and other services, as efficiently as possible. This helps you stay safe and also helps you avoid damaging the cables, minimising costly accidents.
The Easyloc receiver shows the signal level received and marks the maximum with a marker. This means operators work with both an audio signal and visual confirmation at all times. Depth measurement is possible at the push of a button, even when using the power mode, but only with Easyloc Standard.
Easyloc RxTx is suitable for water, rail, gas, power, highways, and telecommunication utilities, as well as contractors, groundworks, building, local authorities, civil engineering, street lighting and fencing, and gardening and landscaping companies.
Caractéristiques
| Transmitter | |
| Operating Time | > 40 hours |
| Power Supply | 6 x IEC R20 1.5 V (D) |
| Working / Storage Temperature | -4 to 131°F (-20 to 55°C) / -40 to 158°F (-40 to 70°C) |
| Protection Class | IP54 |
| Dimensions | 10.24 x 10.04 x 5.51" (26 x 25.5 x 14 cm) |
| Weight | 5.73 lbs (2.6 kg) |
| Receiver | |
| Operating Time | > 40 hours |
| Power Supply | 10 x IEC R6 1.5 V (AA) |
| Working / Storage Temperature | -4 to 131°F (-20 to 55°C) / -40 to 158°F (-40 to 70°C) |
| Protection Class | IP56 / IP67 (up to the bottom of the battery case) |
| Dimensions | 3.94 x 26.38 x 10.24" (10 x 67 x 26 cm) |
| Weight | 5.5 lbs (2.5 kg) |
| EasyLoc Systems | |
| Passive Frequencies | Radio: 15 to 23 kHz Power: 50 to 250 Hz |
| Active Frequencies | 100 / 120 Hz 8.44 kHz 33 kHz |
| Depth Measurements | Cables: 11.81 to 196.85" (0.3 to 5 m) Sondes: 11.81 to 275.59" (0.3 to 7 m) |
| Output Power | 0.1 W 0.5 W 2 W Continuous and pulsed signal (switchable) |
| Application | Cable and pipe location |
Cliquer sur une catégorie pour voir une sélection d'accessoires compatible avec le Megger 1015123 Easyloc Plus Utility Location System Set with grounding set, 33 kHz/8.4 kHz, english version.
| Transmitter | |
| Operating Time | > 40 hours |
| Power Supply | 6 x IEC R20 1.5 V (D) |
| Working / Storage Temperature | -4 to 131°F (-20 to 55°C) / -40 to 158°F (-40 to 70°C) |
| Protection Class | IP54 |
| Dimensions | 10.24 x 10.04 x 5.51" (26 x 25.5 x 14 cm) |
| Weight | 5.73 lbs (2.6 kg) |
| Receiver | |
| Operating Time | > 40 hours |
| Power Supply | 10 x IEC R6 1.5 V (AA) |
| Working / Storage Temperature | -4 to 131°F (-20 to 55°C) / -40 to 158°F (-40 to 70°C) |
| Protection Class | IP56 / IP67 (up to the bottom of the battery case) |
| Dimensions | 3.94 x 26.38 x 10.24" (10 x 67 x 26 cm) |
| Weight | 5.5 lbs (2.5 kg) |
| EasyLoc Systems | |
| Passive Frequencies | Radio: 15 to 23 kHz Power: 50 to 250 Hz |
| Active Frequencies | 100 / 120 Hz 8.44 kHz 33 kHz |
| Depth Measurements | Cables: 11.81 to 196.85" (0.3 to 5 m) Sondes: 11.81 to 275.59" (0.3 to 7 m) |
| Output Power | 0.1 W 0.5 W 2 W Continuous and pulsed signal (switchable) |
| Application | Cable and pipe location |
Cliquer sur une catégorie pour voir une sélection d'accessoires compatible avec le Megger 1015123 Easyloc Plus Utility Location System Set with grounding set, 33 kHz/8.4 kHz, english version.