Megger 1005-984 TDR500/3 CTV Handheld Time Domain Reflectometer, with BNC Adapter

Modèle: TDR500/3 CTV | No. de commande: 1005-984 | CUP: 5036175229927

Megger 1005-984 TDR500/3 CTV Handheld Time Domain Reflectometer, with BNC Adapter

Modèle: TDR500/3 CTV | No. de commande: 1005-984 | CUP: 5036175229927

Ideal for locating faults on metallic cables, the compact and handheld time domain reflectometer has a minimum resolution of 0.1 m and a 5 km maximum range. Features simple operation, AUTO set up for instant use, and ultra-fast pulse for near end fault identification. Two 4 mm-safety terminals

Ideal for locating faults on metallic cables, the compact and handheld time domain reflectometer has a minimum resolution of 0.1 m and a 5 km maximum range. Features simple operation, AUTO set up for instant use, and ultra-fast pulse for near end fault identification. Two 4 mm-safety terminals

Prix régulier $1750.00 CAD
Disponibilité 4 à 5 semaines
Quantité

Megger TDR500/3 Handheld Time Domain Reflectometer

The TDR500/3 is a hand held, compact Time Domain Reflectometer for locating faults on metallic cables. It has a minimum resolution of 0.1 m/0.3 ft and a 5 km/15 kft maximum range depending on velocity factor selected and cable type.

Four output impedances are available (25, 50, 75, and 100 Ω) and a velocity factor between 0.2 and 0.99 will meet any cable test requirements

The TDR500/3 has a simple selection option which together with a 4 way control switch offers an intuitive operation for the user.

Features

  • Backlit graphics monochrome LCD (256 x 128)
  • Adjustable display contrast
  • Resolution to 0.1 m
  • For use on Telecom TNV-3 circuit, or 150V CAT IV power circuits
  • Power blocking filter not required
  • Environmental protection to IP54
  • 2ns pulse for near end fault location
  • AUTO option selecting gain and pulse for each range
  • Display distance in metres or feet
  • Uses five AA (LR6) primary cells

Megger TDR500/3 CTV Specifications

Range 10 m, 25 m, 100 m, 250 m, 1000 m, 2500 m, 5000 m
(30 ft, 75 ft, 300 ft, 750 ft, 3000 ft, 7500 ft, 15000 ft)
Accuracy ±1% of range ± pixel at 0.67 VF
[Note - The measurement accuracy is for the indicated cursor position only and is conditional on the velocity factor being correct.]
Resolution 1% of range
Input protection This instrument complies with IEC61010-1 for connection to live systems up to 150 V CAT IV when used with the optional fused test lead set
Output pulse 5 volts peak to peak into open circuit. Pulse widths determined by range and cable
Gain Set for each range with three user selectable steps (in manual operating mode)
Velocity factor Variable from 0.2 to 0.99 in steps of 0.01
TX null Automatic
Power down Automatic after 5 minutes with no key press
Backlight Stays on for 1 minute with no key press
Battery Five LR6 (AA) type batteries, Manganese alkali or nickel metal-hydride cells
Battery life Up to 14 hours (typical)
IP rating The instrument is designed for use indoors or outdoors and is rated to IP54
Dimensions 9.05 x 4.52 x 1.88" (230 x 115 x 48 mm) LBD
Weight 0.6 kg
Case ABS
Connectors Two 4 mm-safety terminals
Test lead 1 pair 2 meters long consisting of 2 x 4 mm shrouded connector to miniature crocodile clips
Display 256 x 128 pixel Graphics LCD
Cliquer ici pour toutes les spécifications du Megger TDR500/3 CTV

Le Megger TDR500/3 CTV comprend

  • Megger 1005-984 TDR500/3 CTV Handheld Time Domain Reflectometer, with BNC Adapter

Cliquer sur une catégorie pour voir une sélection d'accessoires compatible avec le Megger 1005-984 TDR500/3 CTV Handheld Time Domain Reflectometer, with BNC Adapter .

Megger 6231-694 Short Lead Set, BNC to Crocodile Clips, TDR500 6231-694
Includes two 1-Feet (300mm) test leads with crocodile clips. The crocodile clips provide hands-free connection to a conductor. For use with Megger 655500 (TDR500) Time Domain Reflectometer.




Megger 1006-511 Fused Power Test Lead Set, Retractable 1006-511
Designed for use with the for TDR500/3 and TDR1000/3P handheld Time Domain Reflectometers. The fused lead set (red/black) is made with a retractable sheath and is rated at 500 mA.




Poser une question sur le Megger 1005-984 TDR500/3 CTV Handheld Time Domain Reflectometer, with BNC Adapter

Megger TDR500/3 Handheld Time Domain Reflectometer

The TDR500/3 is a hand held, compact Time Domain Reflectometer for locating faults on metallic cables. It has a minimum resolution of 0.1 m/0.3 ft and a 5 km/15 kft maximum range depending on velocity factor selected and cable type.

Four output impedances are available (25, 50, 75, and 100 Ω) and a velocity factor between 0.2 and 0.99 will meet any cable test requirements

The TDR500/3 has a simple selection option which together with a 4 way control switch offers an intuitive operation for the user.

Features

  • Backlit graphics monochrome LCD (256 x 128)
  • Adjustable display contrast
  • Resolution to 0.1 m
  • For use on Telecom TNV-3 circuit, or 150V CAT IV power circuits
  • Power blocking filter not required
  • Environmental protection to IP54
  • 2ns pulse for near end fault location
  • AUTO option selecting gain and pulse for each range
  • Display distance in metres or feet
  • Uses five AA (LR6) primary cells

Megger TDR500/3 CTV Specifications

Range 10 m, 25 m, 100 m, 250 m, 1000 m, 2500 m, 5000 m
(30 ft, 75 ft, 300 ft, 750 ft, 3000 ft, 7500 ft, 15000 ft)
Accuracy ±1% of range ± pixel at 0.67 VF
[Note - The measurement accuracy is for the indicated cursor position only and is conditional on the velocity factor being correct.]
Resolution 1% of range
Input protection This instrument complies with IEC61010-1 for connection to live systems up to 150 V CAT IV when used with the optional fused test lead set
Output pulse 5 volts peak to peak into open circuit. Pulse widths determined by range and cable
Gain Set for each range with three user selectable steps (in manual operating mode)
Velocity factor Variable from 0.2 to 0.99 in steps of 0.01
TX null Automatic
Power down Automatic after 5 minutes with no key press
Backlight Stays on for 1 minute with no key press
Battery Five LR6 (AA) type batteries, Manganese alkali or nickel metal-hydride cells
Battery life Up to 14 hours (typical)
IP rating The instrument is designed for use indoors or outdoors and is rated to IP54
Dimensions 9.05 x 4.52 x 1.88" (230 x 115 x 48 mm) LBD
Weight 0.6 kg
Case ABS
Connectors Two 4 mm-safety terminals
Test lead 1 pair 2 meters long consisting of 2 x 4 mm shrouded connector to miniature crocodile clips
Display 256 x 128 pixel Graphics LCD
Cliquer ici pour toutes les spécifications du Megger TDR500/3 CTV

Le Megger TDR500/3 CTV comprend

  • Megger 1005-984 TDR500/3 CTV Handheld Time Domain Reflectometer, with BNC Adapter

Cliquer sur une catégorie pour voir une sélection d'accessoires compatible avec le Megger 1005-984 TDR500/3 CTV Handheld Time Domain Reflectometer, with BNC Adapter .

Megger 6231-694 Short Lead Set, BNC to Crocodile Clips, TDR500 6231-694
Includes two 1-Feet (300mm) test leads with crocodile clips. The crocodile clips provide hands-free connection to a conductor. For use with Megger 655500 (TDR500) Time Domain Reflectometer.




Megger 1006-511 Fused Power Test Lead Set, Retractable 1006-511
Designed for use with the for TDR500/3 and TDR1000/3P handheld Time Domain Reflectometers. The fused lead set (red/black) is made with a retractable sheath and is rated at 500 mA.




Poser une question sur le Megger 1005-984 TDR500/3 CTV Handheld Time Domain Reflectometer, with BNC Adapter

Plus de produits Megger