55800 is a highly sensitive refrigerant leak detector that uses a metal oxide gas sensor for the detection of CFCs, HCFCs, and HFCs refrigerants. This Intellasense leak detector has a powerful microprocessor that will automatically select the best operating conditions for the sensor to optimize its performance. Ideal for the service technician looking to locate a leak in a residential or commercial HVAC/R system as well as an automotive refrigeration system.

55800 is a highly sensitive refrigerant leak detector that uses a metal oxide gas sensor for the detection of CFCs, HCFCs, and HFCs refrigerants. This Intellasense leak detector has a powerful microprocessor that will automatically select the best operating conditions for the sensor to optimize its performance. Ideal for the service technician looking to locate a leak in a residential or commercial HVAC/R system as well as an automotive refrigeration system.

Votre prix $441.00 CAD
Disponibilité 2 à 3 semaines
Quantité

Mastercool 55800 offre

This refrigerant leak detector can detect leaks that range from 0.5 oz./year on low sensitivity to 0.05 oz./year on the high sensitivity level. When locating a leak, the technician can easily switch from one level of sensitivity by pressing the H M L Sensitivity button on the keypad. The unit also has an F mode “Super Sensitive Function” that allows a greater sensitivity beyond the standard setting for locating small leaks with gasses such as R1234yf and R407C.
The leak detector’s keypad allows the technician to select the sensitivity level, to control the unit’s beep volume, a HOLD button, and a PEAK button. The HOLD button retains the visual indication of a leak when it is being used in hard-to-reach locations, and the PEAK button is helpful for identifying the largest leak when a system has multiple leaks.
The instrument’s LCD screen provides the technician with a variety of information including the readiness status of the unit, sensitivity level selected, error signals, and a visual indication of the concentration of refrigerant gases detected.
The refrigerant leak detector’s 16” probe has an intelligent tip design that senses the environmental conditions to eliminate possible false alarms.
The 55800 is operated by 2 “D” batteries with a low battery indicator on the LCD screen. The sensor has a life expectancy of about 2000 hours and the detector comes with a leak test vial to test that the leak detector is working properly.

Caractéristiques

  • Detects combustible gases, hydrogen, all CFCs, HCFCs, and HFCs refrigerants
  • Sensitivity: High 0.05 oz. /year; Medium 0.25 oz./year; Low 0.5 oz./year
  • Test and approved to work with R123ryf, R32, and R410a
  • Sensor life: 2000 hours
  • Certified by ACSI to meet SAE J2791, J2913 and EN14624
  • Unique tip design eliminates false alarms by sensing the condition of the environment
  • 16" (40.64 cm) Flexible probe
  • Attractive display with LCD vertical bars for leak levels and selected sensitivity range
  • Attractive LCD displays WAIT mode to indicate warm up, READY to indicate the unit is ready to measure, INT to indicate poor external measurement conditions or damaged unit, battery indication, H[igh] M[edium] L[ow] to indicate selected sensitivty range, codes E1-E9 for diagnostic error codes, and Green, Yellow, and Red vertical signal bars
  • Keypad features ON/OFF, Volume/Mute, H[igh] M[edium] and L[ow] for sensitivity, HOLD to freeze signal bars, and PEAK
  • Runs off of (2) D Batteries; 60 hours continuous use runtime
  • Meets and exceeds J2791 (R134a), J2913 (R1234yf) and EN 14624

Applications

  • Industrial
  • HVAC/R

Le Mastercool 55800 comprend

  • Refrigerant Leak Detector
  • Replacement Filters
  • Leak Test Vial
  • 2 x "D" Batteries
  • Blow Molded Case
  • Two-Year Warranty

Poser une question sur le Mastercool 55800 Intellasense Refrigerant Leak Detector, High Sensitivity

Mastercool 55800 offre

This refrigerant leak detector can detect leaks that range from 0.5 oz./year on low sensitivity to 0.05 oz./year on the high sensitivity level. When locating a leak, the technician can easily switch from one level of sensitivity by pressing the H M L Sensitivity button on the keypad. The unit also has an F mode “Super Sensitive Function” that allows a greater sensitivity beyond the standard setting for locating small leaks with gasses such as R1234yf and R407C.
The leak detector’s keypad allows the technician to select the sensitivity level, to control the unit’s beep volume, a HOLD button, and a PEAK button. The HOLD button retains the visual indication of a leak when it is being used in hard-to-reach locations, and the PEAK button is helpful for identifying the largest leak when a system has multiple leaks.
The instrument’s LCD screen provides the technician with a variety of information including the readiness status of the unit, sensitivity level selected, error signals, and a visual indication of the concentration of refrigerant gases detected.
The refrigerant leak detector’s 16” probe has an intelligent tip design that senses the environmental conditions to eliminate possible false alarms.
The 55800 is operated by 2 “D” batteries with a low battery indicator on the LCD screen. The sensor has a life expectancy of about 2000 hours and the detector comes with a leak test vial to test that the leak detector is working properly.

Caractéristiques

  • Detects combustible gases, hydrogen, all CFCs, HCFCs, and HFCs refrigerants
  • Sensitivity: High 0.05 oz. /year; Medium 0.25 oz./year; Low 0.5 oz./year
  • Test and approved to work with R123ryf, R32, and R410a
  • Sensor life: 2000 hours
  • Certified by ACSI to meet SAE J2791, J2913 and EN14624
  • Unique tip design eliminates false alarms by sensing the condition of the environment
  • 16" (40.64 cm) Flexible probe
  • Attractive display with LCD vertical bars for leak levels and selected sensitivity range
  • Attractive LCD displays WAIT mode to indicate warm up, READY to indicate the unit is ready to measure, INT to indicate poor external measurement conditions or damaged unit, battery indication, H[igh] M[edium] L[ow] to indicate selected sensitivty range, codes E1-E9 for diagnostic error codes, and Green, Yellow, and Red vertical signal bars
  • Keypad features ON/OFF, Volume/Mute, H[igh] M[edium] and L[ow] for sensitivity, HOLD to freeze signal bars, and PEAK
  • Runs off of (2) D Batteries; 60 hours continuous use runtime
  • Meets and exceeds J2791 (R134a), J2913 (R1234yf) and EN 14624

Applications

  • Industrial
  • HVAC/R

Le Mastercool 55800 comprend

  • Refrigerant Leak Detector
  • Replacement Filters
  • Leak Test Vial
  • 2 x "D" Batteries
  • Blow Molded Case
  • Two-Year Warranty