This unit is for EVAP, turbo/intake, and heavy duty truck testing, providing a solution to difficult-to-diagnose automotive leaks. Mobile repairs are now possible as this unit includes an internal compressor which allows use without the need of shop air while also having the ability to utilize shop air and inert gases.
This unit is for EVAP, turbo/intake, and heavy duty truck testing, providing a solution to difficult-to-diagnose automotive leaks. Mobile repairs are now possible as this unit includes an internal compressor which allows use without the need of shop air while also having the ability to utilize shop air and inert gases.
This specifically engineered unit allows today's technician to quickly and efficiently locate and repair the complete spectrum of EVAP, turbo, heavy-duty truck, intakes, exhausts, vacuum lines, cooling systems, manifolds, catalytic converters, brake boosters, passenger compartment air, water leaks, and much more. This kit includes all the adapters for EVAP, high-pressure, and heavy-duty truck testing. Mastercool now offers the professional technician the capability of complete automotive smoke detection testing in a single unit. Mastercool now offers the professional technician the capability of complete automotive smoke detection testing in a single unit.
Caractéristiques
Voltage | 12 VDC |
Input Pressure | Maximum 100 PSI (7 bar) |
Output Pressure | EVAP 12 to 14" H2O (30 to 35 mBar) HP internal pump maximum 22 PSI (150 kPa) HP external pressure source maximum 28 PSI (190 kPa) |
Safety Pressure Relief | 120 (±5) PSI |
Oil Fill Line Indicator | 3.4 oz (100 ml (±10 ml)) |
Flow Meter | 0 to 0.040" (0 to 1.0 mm) |
Power Consumption | Maximum 6.5 A |
Operating Temperature | 0 to 140°F (-17 to 60°C ) |
Operating Humidity | No Restrictions |
Operating Altitude | No Restrictions |
Vapor Output Hose | 10' (3 m) |
Power Cable | 10' (3 m) |
Pressure Supply | Air/Inert gas/Pump |
Auto Shut-Off | 5 minutes |
Dimensions | 11.8 x 9.5 x 11" (300 x 241 x 280 mm) |
Weight | 10.13 lbs (5 kg) |
Voltage | 12 VDC |
Input Pressure | Maximum 100 PSI (7 bar) |
Output Pressure | EVAP 12 to 14" H2O (30 to 35 mBar) HP internal pump maximum 22 PSI (150 kPa) HP external pressure source maximum 28 PSI (190 kPa) |
Safety Pressure Relief | 120 (±5) PSI |
Oil Fill Line Indicator | 3.4 oz (100 ml (±10 ml)) |
Flow Meter | 0 to 0.040" (0 to 1.0 mm) |
Power Consumption | Maximum 6.5 A |
Operating Temperature | 0 to 140°F (-17 to 60°C ) |
Operating Humidity | No Restrictions |
Operating Altitude | No Restrictions |
Vapor Output Hose | 10' (3 m) |
Power Cable | 10' (3 m) |
Pressure Supply | Air/Inert gas/Pump |
Auto Shut-Off | 5 minutes |
Dimensions | 11.8 x 9.5 x 11" (300 x 241 x 280 mm) |
Weight | 10.13 lbs (5 kg) |