MadgeTech HiTemp140-TC High Temperature Data Logger with SMP Thermocouple Connector, 284°F

Modèle: HiTemp140-TC | No. de commande: 902424-00

MadgeTech HiTemp140-TC High Temperature Data Logger with SMP Thermocouple Connector, 284°F

Modèle: HiTemp140-TC | No. de commande: 902424-00

The HiTemp140-TC is a versatile high temperature data logger featuring an SMP thermocouple connector, compatible with a wide range of thermocouple types. It can operate up to 284°F (140.0°C).

The HiTemp140-TC is a versatile high temperature data logger featuring an SMP thermocouple connector, compatible with a wide range of thermocouple types. It can operate up to 284°F (140.0°C).

Prix spécial $682.29 CAD
Prix régulier $722.00 CAD
Disponibilité 2 à 3 semaines
Quantité

MadgeTech HiTemp140-TC offre

The HiTemp140-TC is a versatile high temperature data logger featuring an SMP thermocouple connector. Compatible with a wide variety of thermocouple probes, this data logger is capable of measuring temperature as high as 3308°F (1820°C) and as low as -454°F (-270°C) (probe dependent).

All of MadgeTech’s HiTemp140 data loggers are made of food grade stainless steel and can be placed in environments with temperatures as high as 284°F (140°C). The operating range of the data logger body can be extended to higher temperatures when used with MadgeTech’s thermal barrier options and suitable probe.

Using the MadgeTech 4 Software, starting, stopping and downloading the HiTemp140-TC is simple and easy. To use, simply place the HiTemp140-TC in the IFC400 or IFC406 docking station (sold separately). Using the software, an immediate or delay start can be chosen, as well as the reading rate. Start the data logger, remove it from the docking station and the device is ready to be deployed. Graphical, tabular and summary data is provided for analysis and data can be viewed in °C, °F, K, °R, or mV. The data can also be automatically exported to Excel® for further calculations.

Caractéristiques

  • Measurement range of -454 to 3308°F (-270 to 1820°C)
  • ±0.9°F (±0.5°C) accuracy (probe dependent)
  • SMP thermocouple
  • User replaceable battery
  • Trigger options
  • Programmable start and stop time

Applications

  • Depyrogenation
  • Food preparation and processing
  • Environmental studies
  • Well monitoring
  • Pasteurization
  • Many more applications (probe dependent)

Spécifications pour le MadgeTech HiTemp140-TC

Internal
Temperature Range -40°F to 284°F (-40 to 140°C)
Temperature Resolution 0.02°F (0.01°C)
Calibrated Accuracy ±0.9°F from 32 to 122°F (±0.5°C from 0 to 50°C)
Thermocouple
Thermocouple Types J, K, T, E, R, S, B, N
Meaurement Range -454 to 3308°F (-270 to 1820°C) (Probe Dependent)
Connector Type Female subminiature (SMP)
Cold Junction Compensation Automatic, based on internal channel
Maximum Thermocouple Resistance 100 Ω
Thermocouple J
Range: -346 to 1400°F (-210 to 760°C)
Resolution: 0.18°F (0.1°C)
Accuracy: ±0.9°F (±0.5°C)

K
Range: -454 to 2498°F (-270 to 1370°C)
Resolution: 0.18°F (0.1°C)
Accuracy: ±0.9°F (±0.5°C)

T
Range: -454 to 752°F (-270 to 400°C)
Resolution: 0.18°F (0.1°C)
Accuracy: ±0.9°F (±0.5°C)

E
Range: -454 to 1796°F (-270 to 980°C)
Resolution: 0.18°F (0.1°C)
Accuracy: ±0.9°F (±0.5°C)

R
Range: -58 to 3200°F (-50 to 1760°C)
Resolution: 0.9°F (0.5°C)
Accuracy: ±3.6°F (±2.0°C)

S
Range: -58 to 3200°F (-50 to 1760°C)
Resolution: 0.9°F (0.5°C)
Accuracy: ±3.6°F (±2.0°C)

B
Range: 122 to 3308°F (50 to 1820°C)
Resolution: 0.9°F (0.5°C)
Accuracy: ±3.6°F (±2.0°C)

N
Range: -454 to 2372°F (-270 to 1300°C)
Resolution: 0.18°F (0.1°C)
Accuracy: ±0.9°F (±0.5°C)
General Specifications
Start Modes Software programmable immediate start; Delay start up to 18 months in advance
Stop Modes Manual or Timed (specific date and time)
Real Time Recording May be used with PC to monitor and record data in real time
Password Protection Optional password may be programmed to restrict configuration access
Memory 16,256 readings
5,418 readings in trigger settings mode
Wrap Around Yes
Reading Rate 1 reading per second up to 1 reading every 24 hours
Calibration Digital calibration through software
Calibration Date Automatically recorded within device
Battery Type: 3.6V high-temperature lithium battery; user replaceable
Life: 2 years typical (1 minute reading rate at 77°F (25°C))
Data Format Date and time stamped °C, K, °F, °R, or mV
Time Accuracy ±1 minute/month at 77 °F (25°C)
Computer Interface IFC400 or IFC406 USB docking station required
125,000 baud
Operating System Compatibility Windows XP SP3 or later
Software Compatibility MadgeTech Standard Software version 4.2.25.15 or later
MadgeTech Secure Software version 4.2.24.16 or later
Operating Environment -40 °C to +140 °C (-40 °F to +284 °F); 0 %RH to 100 %RH non-condensing, 0.002 PSIA to 100 PSIA
IP Rating IP50
Material 316 Stainless Steel, PPSU, Glass-Filled Thermoplastic
Approvals CE
Dimensions Body: 2.20 x 1.0 x 1.0" (55.9 x 26.4 x 26.4 mm)
Weight 3.49 oz (99 g)

Le MadgeTech HiTemp140-TC comprend

  • MadgeTech HiTemp140-TC High Temperature Data Logger with SMP Thermocouple Connector, 284°F

Cliquer sur une catégorie pour voir une sélection d'accessoires compatible avec le MadgeTech HiTemp140-TC High Temperature Data Logger with SMP Thermocouple Connector, 284°F.

MadgeTech HiTemp140-O-Ring Ensemble de joints toriques de remplacement pour la série HiTemp140 HiTemp140-O-Ring
Compatible avec la série d'enregistreurs de données HiTemp140, cet ensemble de joints toriques de remplacement garantit une étanchéité sécurisée et étanche pour les environnements à haute température. De plus, ces anneaux sont parfaits pour maintenir l’intégrité et les performances de l’appareil.




MadgeTech Key Ring End Cap pour la série HiTemp140/PRTemp140/PR140/RHTemp1000 Key Ring End Cap
Compatible avec les enregistreurs de données des séries HiTemp140, PRTemp140, PR140 et RHTemp1000, cet embout porte-clés est utilisé à la place du fond standard. De plus, cet anneau peut facilement s'attacher à votre porte-clés ou à votre cordon.




MadgeTech MagMount-1 Support magnétique pour les PR140/PRTemp140/séries HiTemp140/Temp1000/RHTemp1000 MagMount-1
Compatible avec les enregistreurs de données PR140, PRTemp140, HiTemp140, Temp1000 et RHTemp1000, ce support magnétique peut être placé dans des environnements de -80 à 80°C (-112 à 176°F), ce qui le rend idéal pour une utilisation dans les réfrigérateurs et les congélateurs, et les incubateurs.




MadgeTech MultiMount-Z Support polyvalent pour la série HiTemp140 MultiMount-Z
Compatible avec la série d'enregistreurs de données HiTemp140, ce support polyvalent est idéal pour stabiliser un enregistreur à l'intérieur d'un autoclave ou vissé sur une surface plane pour créer une base ancrée. De plus, ce support peut résister à des températures allant jusqu'à 150°C (302°F), ce qui le rend idéal pour une utilisation dans les processus de stérilisation en autoclave.




MadgeTech DLS100 Support polyvalent pour la série HiTemp140/PRTemp140/PR140/Temp1000/RHTemp1000 DLS100
Compatible avec les enregistreurs de données des séries HiTemp140, PRTemp140, PR140, Temp1000 et RHTemp1000, ce support polyvalent en acier inoxydable 316 est lesté pour aider à stabiliser les enregistreurs de données pendant leur utilisation ou utilisé comme support lorsque l'enregistreur est stocké. De plus, ce support peut résister à des températures allant jusqu'à 150°C (302°F).




MadgeTech IFC400 Ensemble de câbles d'interface IFC400
Ensemble de câbles d'interface pour enregistreurs de données HiTemp140 et PR140. Comprend un CD du logiciel MadgeTech, un manuel du logiciel, un guide de démarrage rapide, un câble USB et une station d'accueil USB.




MadgeTech IFC406 Multiplexer Data Logger Interface IFC406
Multiplexer data logger interface allows for six data loggers to be connected and communicate through one USB port.




MadgeTech 902063-00 Flat End Cap with spring for the 140 series End Cap
Flat end cap with spring, designed for use with the 140 Series data loggers. Ideal for secure and reliable enclosure.




Poser une question sur le MadgeTech HiTemp140-TC High Temperature Data Logger with SMP Thermocouple Connector, 284°F

MadgeTech HiTemp140-TC offre

The HiTemp140-TC is a versatile high temperature data logger featuring an SMP thermocouple connector. Compatible with a wide variety of thermocouple probes, this data logger is capable of measuring temperature as high as 3308°F (1820°C) and as low as -454°F (-270°C) (probe dependent).

All of MadgeTech’s HiTemp140 data loggers are made of food grade stainless steel and can be placed in environments with temperatures as high as 284°F (140°C). The operating range of the data logger body can be extended to higher temperatures when used with MadgeTech’s thermal barrier options and suitable probe.

Using the MadgeTech 4 Software, starting, stopping and downloading the HiTemp140-TC is simple and easy. To use, simply place the HiTemp140-TC in the IFC400 or IFC406 docking station (sold separately). Using the software, an immediate or delay start can be chosen, as well as the reading rate. Start the data logger, remove it from the docking station and the device is ready to be deployed. Graphical, tabular and summary data is provided for analysis and data can be viewed in °C, °F, K, °R, or mV. The data can also be automatically exported to Excel® for further calculations.

Caractéristiques

  • Measurement range of -454 to 3308°F (-270 to 1820°C)
  • ±0.9°F (±0.5°C) accuracy (probe dependent)
  • SMP thermocouple
  • User replaceable battery
  • Trigger options
  • Programmable start and stop time

Applications

  • Depyrogenation
  • Food preparation and processing
  • Environmental studies
  • Well monitoring
  • Pasteurization
  • Many more applications (probe dependent)

Spécifications pour le MadgeTech HiTemp140-TC

Internal
Temperature Range -40°F to 284°F (-40 to 140°C)
Temperature Resolution 0.02°F (0.01°C)
Calibrated Accuracy ±0.9°F from 32 to 122°F (±0.5°C from 0 to 50°C)
Thermocouple
Thermocouple Types J, K, T, E, R, S, B, N
Meaurement Range -454 to 3308°F (-270 to 1820°C) (Probe Dependent)
Connector Type Female subminiature (SMP)
Cold Junction Compensation Automatic, based on internal channel
Maximum Thermocouple Resistance 100 Ω
Thermocouple J
Range: -346 to 1400°F (-210 to 760°C)
Resolution: 0.18°F (0.1°C)
Accuracy: ±0.9°F (±0.5°C)

K
Range: -454 to 2498°F (-270 to 1370°C)
Resolution: 0.18°F (0.1°C)
Accuracy: ±0.9°F (±0.5°C)

T
Range: -454 to 752°F (-270 to 400°C)
Resolution: 0.18°F (0.1°C)
Accuracy: ±0.9°F (±0.5°C)

E
Range: -454 to 1796°F (-270 to 980°C)
Resolution: 0.18°F (0.1°C)
Accuracy: ±0.9°F (±0.5°C)

R
Range: -58 to 3200°F (-50 to 1760°C)
Resolution: 0.9°F (0.5°C)
Accuracy: ±3.6°F (±2.0°C)

S
Range: -58 to 3200°F (-50 to 1760°C)
Resolution: 0.9°F (0.5°C)
Accuracy: ±3.6°F (±2.0°C)

B
Range: 122 to 3308°F (50 to 1820°C)
Resolution: 0.9°F (0.5°C)
Accuracy: ±3.6°F (±2.0°C)

N
Range: -454 to 2372°F (-270 to 1300°C)
Resolution: 0.18°F (0.1°C)
Accuracy: ±0.9°F (±0.5°C)
General Specifications
Start Modes Software programmable immediate start; Delay start up to 18 months in advance
Stop Modes Manual or Timed (specific date and time)
Real Time Recording May be used with PC to monitor and record data in real time
Password Protection Optional password may be programmed to restrict configuration access
Memory 16,256 readings
5,418 readings in trigger settings mode
Wrap Around Yes
Reading Rate 1 reading per second up to 1 reading every 24 hours
Calibration Digital calibration through software
Calibration Date Automatically recorded within device
Battery Type: 3.6V high-temperature lithium battery; user replaceable
Life: 2 years typical (1 minute reading rate at 77°F (25°C))
Data Format Date and time stamped °C, K, °F, °R, or mV
Time Accuracy ±1 minute/month at 77 °F (25°C)
Computer Interface IFC400 or IFC406 USB docking station required
125,000 baud
Operating System Compatibility Windows XP SP3 or later
Software Compatibility MadgeTech Standard Software version 4.2.25.15 or later
MadgeTech Secure Software version 4.2.24.16 or later
Operating Environment -40 °C to +140 °C (-40 °F to +284 °F); 0 %RH to 100 %RH non-condensing, 0.002 PSIA to 100 PSIA
IP Rating IP50
Material 316 Stainless Steel, PPSU, Glass-Filled Thermoplastic
Approvals CE
Dimensions Body: 2.20 x 1.0 x 1.0" (55.9 x 26.4 x 26.4 mm)
Weight 3.49 oz (99 g)

Le MadgeTech HiTemp140-TC comprend

  • MadgeTech HiTemp140-TC High Temperature Data Logger with SMP Thermocouple Connector, 284°F

Cliquer sur une catégorie pour voir une sélection d'accessoires compatible avec le MadgeTech HiTemp140-TC High Temperature Data Logger with SMP Thermocouple Connector, 284°F.

MadgeTech HiTemp140-O-Ring Ensemble de joints toriques de remplacement pour la série HiTemp140 HiTemp140-O-Ring
Compatible avec la série d'enregistreurs de données HiTemp140, cet ensemble de joints toriques de remplacement garantit une étanchéité sécurisée et étanche pour les environnements à haute température. De plus, ces anneaux sont parfaits pour maintenir l’intégrité et les performances de l’appareil.




MadgeTech Key Ring End Cap pour la série HiTemp140/PRTemp140/PR140/RHTemp1000 Key Ring End Cap
Compatible avec les enregistreurs de données des séries HiTemp140, PRTemp140, PR140 et RHTemp1000, cet embout porte-clés est utilisé à la place du fond standard. De plus, cet anneau peut facilement s'attacher à votre porte-clés ou à votre cordon.




MadgeTech MagMount-1 Support magnétique pour les PR140/PRTemp140/séries HiTemp140/Temp1000/RHTemp1000 MagMount-1
Compatible avec les enregistreurs de données PR140, PRTemp140, HiTemp140, Temp1000 et RHTemp1000, ce support magnétique peut être placé dans des environnements de -80 à 80°C (-112 à 176°F), ce qui le rend idéal pour une utilisation dans les réfrigérateurs et les congélateurs, et les incubateurs.




MadgeTech MultiMount-Z Support polyvalent pour la série HiTemp140 MultiMount-Z
Compatible avec la série d'enregistreurs de données HiTemp140, ce support polyvalent est idéal pour stabiliser un enregistreur à l'intérieur d'un autoclave ou vissé sur une surface plane pour créer une base ancrée. De plus, ce support peut résister à des températures allant jusqu'à 150°C (302°F), ce qui le rend idéal pour une utilisation dans les processus de stérilisation en autoclave.




MadgeTech DLS100 Support polyvalent pour la série HiTemp140/PRTemp140/PR140/Temp1000/RHTemp1000 DLS100
Compatible avec les enregistreurs de données des séries HiTemp140, PRTemp140, PR140, Temp1000 et RHTemp1000, ce support polyvalent en acier inoxydable 316 est lesté pour aider à stabiliser les enregistreurs de données pendant leur utilisation ou utilisé comme support lorsque l'enregistreur est stocké. De plus, ce support peut résister à des températures allant jusqu'à 150°C (302°F).




MadgeTech IFC400 Ensemble de câbles d'interface IFC400
Ensemble de câbles d'interface pour enregistreurs de données HiTemp140 et PR140. Comprend un CD du logiciel MadgeTech, un manuel du logiciel, un guide de démarrage rapide, un câble USB et une station d'accueil USB.




MadgeTech IFC406 Multiplexer Data Logger Interface IFC406
Multiplexer data logger interface allows for six data loggers to be connected and communicate through one USB port.




MadgeTech 902063-00 Flat End Cap with spring for the 140 series End Cap
Flat end cap with spring, designed for use with the 140 Series data loggers. Ideal for secure and reliable enclosure.




Poser une question sur le MadgeTech HiTemp140-TC High Temperature Data Logger with SMP Thermocouple Connector, 284°F

Plus de produits MadgeTech