The HiTemp140 is a high temperature logger that is built for use with autoclaves and harsh enironments, giving high precision data logging. This model has a 2" (5.08 cm) transitional diameter probe, key ring end cap, and can operate in temperature up to 284°F (140.0°C).
The HiTemp140 is a high temperature logger that is built for use with autoclaves and harsh enironments, giving high precision data logging. This model has a 2" (5.08 cm) transitional diameter probe, key ring end cap, and can operate in temperature up to 284°F (140.0°C).
The HiTemp140 is a rugged, high precision, temperature data logger that is built for use in harsh environments. This stainless steel device is submersible and can withstand temperatures up to 284°F (140°C). With the HiTemp140’s standard calibration, an accuracy of ±0.18 °F (± 0.1°C) can be achieved over a wide temperature range.
The HiTemp140 can store up to 32,512 readings, and features a rigid external probe capable of measuring extended temperatures, up to 500°F (260°C). Custom probe lengths are available up to 7". The device records date and time stamped readings, and has non-volatile solid state memory which retains data even if the battery becomes discharged.
Using the MadgeTech 4 Software, starting, stopping and downloading the HiTemp140 is simple and easy. To use, simply place the HiTemp140 in the IFC400 or IFC406 docking station (sold separately). Using the software, an immediate or delay start can be chosen, as well as the reading rate. Start the data logger, remove it from the docking station and the device is ready to be deployed. Graphical, tabular and summary data is provided for analysis and data can be viewed in °C, °F, K or °R. The data can also be automatically exported to Excel® for further calculations.
Caractéristiques
Applications
Temperature | |
Temperature Sensor | 100 Ω Platinum RTD |
Probe Measurement Range | -328 to 500°F (-200 to 260°C) |
Temperature Resolution | 0.02°F (0.01°C) |
Calibrated Accuracy | ±0.18°F from 68 to 284°F (±0.1°C from 20 to 140°C) ±0.54°F from -4 to 67.98°F (±0.3°C from -20 to 19.99°C) ±0.72°F from -40 to -4.02°F (±0.4°C from -40 to -20.01°C) |
General Specifications | |
Start Modes | Software programmable immediate start; delay up to 18 months in advance |
Stop Modes | Manual or Timed (specific date and time) |
Real Time Recording | May be used with PC to monitor and record real-time data |
Password Protection | An optional password may be programmed into the device to restrict access to configuration options. Data may be read out without the password |
Memory | 32,512 readings |
Trigger Settings | High and Low limits may be set. Once data meets or exceed sets limits, the device will record to memory. Bi-level start and stop triggers can also be programmed. Users can specify the number of readings to take after the device triggers |
Readings in Trigger Settings Mode | 6,502 readings |
Wrap Around | Yes |
Reading Rate | 1/second up to 1/24 hours |
Calibration | Digital calibration via software |
Calibration Date | Automatically recorded |
Battery | Type: 3.6V high-temperature lithium battery, user-replaceable Life: 2 years typical (1 minute reading rate at 77°F (25 °C) |
Data Format | Date and time stamped °C, K, °F, or °R |
Time Accuracy | ±1 minute/month at 60 to 86°F (20 to 30°C) |
Computer Interface | IFC400 or IFC406 USB docking station required 125,000 baud |
Operating System Compatibility | Windows XP SP3 or later |
Software Compatibility | MadgeTech Standard Software v2.03.06 or later MadgeTech Secure Software v4.1.3.0 or later |
Operating Environment | -40 to 284°F (-40 to 140°C) 0 to 100% RH, 0.002 to 100 PSIA |
IP Rating | IP68 |
Material | 316 Stainless Steel, Radel |
Approvals | CE |
Dimensions | Body: 1.9 x 0.97" (48 x 4.6 mm) diameter Probe: 2.0 x 0.125" (0.188" transitional)(51 x 3.2 mm (4.8 mm transitional)) diameter |
Weight | 4.2 oz (120 g) |
Cliquer sur une catégorie pour voir une sélection d'accessoires compatible avec le MadgeTech HiTemp140-2-TD-KR High Temperature Data Logger with a 2" transitional diameter probe, key ring end cap, 284°F.
Temperature | |
Temperature Sensor | 100 Ω Platinum RTD |
Probe Measurement Range | -328 to 500°F (-200 to 260°C) |
Temperature Resolution | 0.02°F (0.01°C) |
Calibrated Accuracy | ±0.18°F from 68 to 284°F (±0.1°C from 20 to 140°C) ±0.54°F from -4 to 67.98°F (±0.3°C from -20 to 19.99°C) ±0.72°F from -40 to -4.02°F (±0.4°C from -40 to -20.01°C) |
General Specifications | |
Start Modes | Software programmable immediate start; delay up to 18 months in advance |
Stop Modes | Manual or Timed (specific date and time) |
Real Time Recording | May be used with PC to monitor and record real-time data |
Password Protection | An optional password may be programmed into the device to restrict access to configuration options. Data may be read out without the password |
Memory | 32,512 readings |
Trigger Settings | High and Low limits may be set. Once data meets or exceed sets limits, the device will record to memory. Bi-level start and stop triggers can also be programmed. Users can specify the number of readings to take after the device triggers |
Readings in Trigger Settings Mode | 6,502 readings |
Wrap Around | Yes |
Reading Rate | 1/second up to 1/24 hours |
Calibration | Digital calibration via software |
Calibration Date | Automatically recorded |
Battery | Type: 3.6V high-temperature lithium battery, user-replaceable Life: 2 years typical (1 minute reading rate at 77°F (25 °C) |
Data Format | Date and time stamped °C, K, °F, or °R |
Time Accuracy | ±1 minute/month at 60 to 86°F (20 to 30°C) |
Computer Interface | IFC400 or IFC406 USB docking station required 125,000 baud |
Operating System Compatibility | Windows XP SP3 or later |
Software Compatibility | MadgeTech Standard Software v2.03.06 or later MadgeTech Secure Software v4.1.3.0 or later |
Operating Environment | -40 to 284°F (-40 to 140°C) 0 to 100% RH, 0.002 to 100 PSIA |
IP Rating | IP68 |
Material | 316 Stainless Steel, Radel |
Approvals | CE |
Dimensions | Body: 1.9 x 0.97" (48 x 4.6 mm) diameter Probe: 2.0 x 0.125" (0.188" transitional)(51 x 3.2 mm (4.8 mm transitional)) diameter |
Weight | 4.2 oz (120 g) |
Cliquer sur une catégorie pour voir une sélection d'accessoires compatible avec le MadgeTech HiTemp140-2-TD-KR High Temperature Data Logger with a 2" transitional diameter probe, key ring end cap, 284°F.