MadgeTech AVS140-1 Autoclave Validation Data Logging System

Modèle: 900013-00 | No. de commande: AVS140-1

MadgeTech AVS140-1 Autoclave Validation Data Logging System-


Télécharger: datasheet

Plus de produits MadgeTech

Demander à un expert

MadgeTech AVS140-1 Autoclave Validation Data Logging System

Modèle: 900013-00 | No. de commande: AVS140-1

A complete system used to perform autoclave validations consisting of a high temperature data logger, an interface cable and software providing tools to users to assist with FDA 21 CFR Part 11 compliance.

A complete system used to perform autoclave validations consisting of a high temperature data logger, an interface cable and software providing tools to users to assist with FDA 21 CFR Part 11 compliance.

Prix spécial $2340.77 CAD
Prix régulier $2477.00 CAD
Disponibilité 2 à 3 semaines
Quantité

Traceable Calibration Certificate Icon

Certificat d’étalonnage de traçabilité pour votre 900013-00 Autoclave Validation Data Logging System

Traceable Calibration Certificate Icon

Certificat d’étalonnage de traçabilité pour votre 900013-00 Autoclave Validation Data Logging System

MadgeTech 900013-00 offre

The Madgetech AVS140-1 Autoclave Validation Data Logging System provides tools to assist with FDA 21 CFR Part 11 compliance. This complete system, which is used to perform autoclave validations, comes with a high-temperature data logger, 1" (2.54 cm) probe, interface cable and Madgetech 4 Secure data logger software.

Caractéristiques

  • Perform autoclave validations
  • Rugged HiTemp140 temperature data logger is made from stainless steel for use with autoclaves and in other harsh environments
  • Logger withstands temperatures up to 284°F (140°C) with ±0.18°F (0.1°C) accuracy
  • Madgetech 4 Secure software license and IQ, OQ and PQ validation protocols provide tools to assist with FDA 21 CFR Part 11 compliance
  • Software contains criteria, such as electronic signatures, access codes, secure data files and an audit trail

Spécifications pour le MadgeTech 900013-00

Temperature Sensor 100 Ω platinum RTD
Temperature Resolution 0.018°F (0.01°C)
Temperature Calibrated Accuracy 68 to 284°F (20 to 140°C): ±0.18°F/±0.1°C, -4 to 67.98°F (-20 to 19.99°C): ±0.54°F/±0.3°C, -40 to -4.02°F (-40 to -20.01°C): ±0.72°F/±0.4°C
Probe Temperature Range -328 to 500°F (-200 to 260°C)
Memory 32,700 readings
Reading Rate 1 reading every second up to 1 reading every 24 hours
Baud Rate 125,000
Material 316 stainless steel
IP Rating IP68
Submersible Yes
Required Interface Package IFC400
CE Compliant Yes
Product Diameter 0.97" (25 mm) body, 0.125" (3.2 mm) probe
Operating Temperature -40 to 284°F (-40 to 140°C)
Product Length 1.55" (40 mm) body, 1" (25 mm) probe
Product Weight 0.5 lbs (226.8 g)

Le MadgeTech 900013-00 comprend

  • HiTemp140-1 Data Logger with 1" (2.54 cm) Probe
  • IFC400 Interface Cable
  • Madgetech 4 Secure Software License
  • Calibration Certificate

How To Validate an Autoclave Using the Madgetech AVS140 System


In this video, the viewer will learn how to validate an autoclave using this validation data logging system. Different types of loggers must be started separately. Additionally, this software provides tools to assist with FDA 21 CFR Part 11 compliance.

Poser une question sur le MadgeTech AVS140-1 Autoclave Validation Data Logging System

MadgeTech 900013-00 offre

The Madgetech AVS140-1 Autoclave Validation Data Logging System provides tools to assist with FDA 21 CFR Part 11 compliance. This complete system, which is used to perform autoclave validations, comes with a high-temperature data logger, 1" (2.54 cm) probe, interface cable and Madgetech 4 Secure data logger software.

Caractéristiques

  • Perform autoclave validations
  • Rugged HiTemp140 temperature data logger is made from stainless steel for use with autoclaves and in other harsh environments
  • Logger withstands temperatures up to 284°F (140°C) with ±0.18°F (0.1°C) accuracy
  • Madgetech 4 Secure software license and IQ, OQ and PQ validation protocols provide tools to assist with FDA 21 CFR Part 11 compliance
  • Software contains criteria, such as electronic signatures, access codes, secure data files and an audit trail

Spécifications pour le MadgeTech 900013-00

Temperature Sensor 100 Ω platinum RTD
Temperature Resolution 0.018°F (0.01°C)
Temperature Calibrated Accuracy 68 to 284°F (20 to 140°C): ±0.18°F/±0.1°C, -4 to 67.98°F (-20 to 19.99°C): ±0.54°F/±0.3°C, -40 to -4.02°F (-40 to -20.01°C): ±0.72°F/±0.4°C
Probe Temperature Range -328 to 500°F (-200 to 260°C)
Memory 32,700 readings
Reading Rate 1 reading every second up to 1 reading every 24 hours
Baud Rate 125,000
Material 316 stainless steel
IP Rating IP68
Submersible Yes
Required Interface Package IFC400
CE Compliant Yes
Product Diameter 0.97" (25 mm) body, 0.125" (3.2 mm) probe
Operating Temperature -40 to 284°F (-40 to 140°C)
Product Length 1.55" (40 mm) body, 1" (25 mm) probe
Product Weight 0.5 lbs (226.8 g)

Le MadgeTech 900013-00 comprend

  • HiTemp140-1 Data Logger with 1" (2.54 cm) Probe
  • IFC400 Interface Cable
  • Madgetech 4 Secure Software License
  • Calibration Certificate

How To Validate an Autoclave Using the Madgetech AVS140 System


In this video, the viewer will learn how to validate an autoclave using this validation data logging system. Different types of loggers must be started separately. Additionally, this software provides tools to assist with FDA 21 CFR Part 11 compliance.

Poser une question sur le MadgeTech AVS140-1 Autoclave Validation Data Logging System

Plus de produits MadgeTech