Leviton CDA01-L12 Current Transformer, 100:0.1A, Solid Core, 0.72", Blue

Modèle: CDA01-L12 | CUP: 078477547137

Leviton CDA01-L12 Current Transformer, 100:0.1A, Solid Core, 0.72", Blue

Modèle: CDA01-L12 | CUP: 078477547137

The Leviton CDA01-L12 solid core current transformer (CT) is cost effective and less susceptible to damage during installation. Solid core CTs slip over power lines to measure the electrical current flowing through the line.

The Leviton CDA01-L12 solid core current transformer (CT) is cost effective and less susceptible to damage during installation. Solid core CTs slip over power lines to measure the electrical current flowing through the line.

Prix spécial $56.64 CAD
Prix régulier $59.00 CAD
Disponibilité 2 à 3 semaines
Quantité

Leviton CDA01-L12 Specifications

Operating Ambient Temperature Rating -30 to 55°C
Relative humidity rating ≤ 90%
Maximum Rated Voltage 600V
Maximum Rated Current
100:0.1A CTs Primary: 100A
Secondary: 110mA (0.11A)
200:0.1A CTs Primary: 200A
Secondary: 110mA (0.11A)
Pollution Degree 2 Normally only non-conductive pollution occurs. Occasionally, however, a temporary conductivity caused by condensation must be expected.
CTs
Size A 0.72" (18.3mm)
Size B 2.06" (52.3mm)
Size C 0.82" (20.8mm)
Size D 48.00" (1219mm)
Cliquer ici pour toutes les spécifications du Leviton CDA01-L12

Le Leviton CDA01-L12 comprend

  • Leviton CDA01-L12 Current Transformer, 100:0.1A, Solid Core, 0.72", Blue

Submetering How To Step 1 - Evaluate Facility

Submetering How To Step 2 - Energy Information Plan

Submetering How To Step 3 - Install

Poser une question sur le Leviton CDA01-L12 Current Transformer, 100:0.1A, Solid Core, 0.72", Blue

Leviton CDA01-L12 Specifications

Operating Ambient Temperature Rating -30 to 55°C
Relative humidity rating ≤ 90%
Maximum Rated Voltage 600V
Maximum Rated Current
100:0.1A CTs Primary: 100A
Secondary: 110mA (0.11A)
200:0.1A CTs Primary: 200A
Secondary: 110mA (0.11A)
Pollution Degree 2 Normally only non-conductive pollution occurs. Occasionally, however, a temporary conductivity caused by condensation must be expected.
CTs
Size A 0.72" (18.3mm)
Size B 2.06" (52.3mm)
Size C 0.82" (20.8mm)
Size D 48.00" (1219mm)
Cliquer ici pour toutes les spécifications du Leviton CDA01-L12

Le Leviton CDA01-L12 comprend

  • Leviton CDA01-L12 Current Transformer, 100:0.1A, Solid Core, 0.72", Blue

Submetering How To Step 1 - Evaluate Facility

Submetering How To Step 2 - Energy Information Plan

Submetering How To Step 3 - Install

Poser une question sur le Leviton CDA01-L12 Current Transformer, 100:0.1A, Solid Core, 0.72", Blue

Plus de produits Leviton