The Leviton A8332-8FD Flex I/O is a cost-effective way to collect data from meters or sensors and bring that information into a Modbus network or energy monitoring system. It can be incorporated with data acquisition and metering devices to provide a cost-effective energy monitoring solution. Power supply not included.
The Leviton A8332-8FD Flex I/O is a cost-effective way to collect data from meters or sensors and bring that information into a Modbus network or energy monitoring system. It can be incorporated with data acquisition and metering devices to provide a cost-effective energy monitoring solution. Power supply not included.
Discontinué!
Ce produit a été discontinué et n’est plus disponible. Il n’y a pas de produit de remplacement direct. Ne vous inquiétez pas, nous avons quelques options pour vous aider à trouver ce dont vous avez besoin:
Visitez notre catégorie Modules pour trouver des produits similaires.
Ou nous ferons une recherche et vous aiderons à trouver ce dont vous avez besoin:
Caractéristiques
Applications
| Device | |
| Processor | ARM7 Field Upgradeable Firmware |
| Memory | Pulse count and runtime values are stored in non-volatile memory |
| LEDs | 8x Input Status LEDs (Red), 2x Modbus TX/RX (Yellow), 1 Power/Alive Status (Green) |
| Power | |
| Power Supply | 24VDC, 200mA, but not to exceed 8A, Required (not included) |
| Communication | |
| Protocols | Modbus/RTU |
| Inputs | |
| Voltage Mode | 0 to 10VDC (min/max/average/instantaneous data) Accuracy +/- 0.25% of full scale at 20C |
| Current Mode | 4 to 20mA (min/max/average/instantaneous data) Accuracy +/- 0.25% of full scale at 20C |
| Resistance Mode | 100 ohms to 100k (see installation for accuracy specification |
| Pulse Mode | Intended for use with dry contact outputs (consumption/rate/runtime/status) Standard and KYZ modes for A and C relay outputs Input Terminals supplies 5V at 5mA sense voltage to detect contact closures Maximum Rate: 10Hz, minimum pulse width 50ms Adjustable Contact Closure Threshold: 100Ω to 5kΩ, broken wire sense above 10kΩ optional |
| Serial Port | RS-485 two wire, 19200 or 9600 baud, 8N1 |
| I/O | 8x Flex IO inputs with user selectable modes: voltage, current, resistance, pulse and status |
| Isolation | Pulse outputs and RS485 ports are isolated to 1500VDC; Power input, RS232 and analog/pulse inputs are non-isolated |
| Outputs | |
| Relays | 2x, Dry Contact (opto-fet) 30 VDC, 150 mA max |
| PHYSICAL | |
| Weight | 3.7oz (105g) |
| Size | 4.13 x 3.39 x 1.18" (105mm x 86mm x 30mm) |
| Environment | |
| North America | -22°F to 158°F (-30°C to 70°C), 0-95% RH, non-condensing |
| Altitude | 2000M Max |
| Pollution | Degree 2 |
| Codes & Standards | |
| Emissions | FCC CFR 47 PART 15, Class A, EN 61000, EN 61326 |
| Safety | UL61010 Recognized, EN61010 |
BMO 3.0 - How to Create a BMO Account and Sign In
BMO 3.0 - How to Add Your First Hub
BMO 3.0 - How to Navigate a Hub
BMO 3.0 - How to Navigate a Device
| Device | |
| Processor | ARM7 Field Upgradeable Firmware |
| Memory | Pulse count and runtime values are stored in non-volatile memory |
| LEDs | 8x Input Status LEDs (Red), 2x Modbus TX/RX (Yellow), 1 Power/Alive Status (Green) |
| Power | |
| Power Supply | 24VDC, 200mA, but not to exceed 8A, Required (not included) |
| Communication | |
| Protocols | Modbus/RTU |
| Inputs | |
| Voltage Mode | 0 to 10VDC (min/max/average/instantaneous data) Accuracy +/- 0.25% of full scale at 20C |
| Current Mode | 4 to 20mA (min/max/average/instantaneous data) Accuracy +/- 0.25% of full scale at 20C |
| Resistance Mode | 100 ohms to 100k (see installation for accuracy specification |
| Pulse Mode | Intended for use with dry contact outputs (consumption/rate/runtime/status) Standard and KYZ modes for A and C relay outputs Input Terminals supplies 5V at 5mA sense voltage to detect contact closures Maximum Rate: 10Hz, minimum pulse width 50ms Adjustable Contact Closure Threshold: 100Ω to 5kΩ, broken wire sense above 10kΩ optional |
| Serial Port | RS-485 two wire, 19200 or 9600 baud, 8N1 |
| I/O | 8x Flex IO inputs with user selectable modes: voltage, current, resistance, pulse and status |
| Isolation | Pulse outputs and RS485 ports are isolated to 1500VDC; Power input, RS232 and analog/pulse inputs are non-isolated |
| Outputs | |
| Relays | 2x, Dry Contact (opto-fet) 30 VDC, 150 mA max |
| PHYSICAL | |
| Weight | 3.7oz (105g) |
| Size | 4.13 x 3.39 x 1.18" (105mm x 86mm x 30mm) |
| Environment | |
| North America | -22°F to 158°F (-30°C to 70°C), 0-95% RH, non-condensing |
| Altitude | 2000M Max |
| Pollution | Degree 2 |
| Codes & Standards | |
| Emissions | FCC CFR 47 PART 15, Class A, EN 61000, EN 61326 |
| Safety | UL61010 Recognized, EN61010 |