The Leviton 4OUMR-R12 outdoor series 4000 ModBus meter kit is a revenue-grade kWh electrical meter. This device combines exceptional performance and easy installation for a cost-effective energy monitoring solution.
The Leviton 4OUMR-R12 outdoor series 4000 ModBus meter kit is a revenue-grade kWh electrical meter. This device combines exceptional performance and easy installation for a cost-effective energy monitoring solution.
Features
Applications
Use the VerifEye Series 4000 Industrial ModBus Meter Kits in commercial, institutional, industrial and government applications for:
| Measurement Accuracy | |
| Real Power and Energy | IEC 62053-22 Class 0.5S, ANSI C12.20 0.5% |
| Reactive Power and Energy | IEC 62053-23 Class 2, 2% |
| Current | 0.4% (+0.015% per °C deviation from 25°C) from 5% to 100% of range; 0.8% (+0.015% per °C deviation from 25°C) from 1% to 5% of range |
| Voltage | 0.4% (+0.015% per °C deviation from 25°C) from 90VL-N to 600VACL-L |
| Sample Rate | 2520 Samples Per Second |
| Data Update Rate | 1 sec |
| Type of Measurement | True RMS up to the 21st harmonic 60 Hz; One to three phase AC system |
| Input Voltage | |
| Measured AC Voltage | Minimum 90VL-N (156VL-L) for stated accuracy UL Maximums: 600VL-L (347VL-N) CE Maximum: 300VL-N |
| Metering Over-Range | +20% |
| Impedance | 2.5 MΩ L-N /5 MΩ L-L |
| Frequency Range | 45 to 65 Hz |
| Input Current | |
| CT Scaling | Primary: Adjustable from 5 A to 32,000 A |
| Measurement Input Range | 0 to 0.333 VAC or 0 to 1.0 VAC (+20% over-range), rated for use with Class 1 voltage inputs |
| Impedance | 10.6 kΩ (1/3 V mode) or 32.1 kΩ (1 V mode) |
| Control Power | |
| AC | 5VA max.; 90V min. UL Maximums: 600VL-L (347 VL-N ) CE Maximum: 300VL-N |
| DC | 3 W max.; UL and CE: 125 to 300VDC |
| Ride Through Time | 100 msec at 120VAC |
| Output | |
| Alarm Contacts | N.C., static output (30VAC/DC, 100mA max. @ 25°C, derate 0.56mA per °C above 25°C) |
| Real Energy Pulse Contacts | N.O., static output (30VAC/DC, 100mA max. @ 25°C, derate 0.56mA per °C above 25°C) |
| RS-485 Port | 2-wire, 1200 to 38400 baud, Modbus RTU |
| Mechanical | |
| Weight | 0.62 lb (0.28 kg) |
| IP Degree of Protection (IEC 60529) | IP40 front display; IP20 Meter |
| Display Characteristics | Back-lit blue LCD |
| Terminal Block Screw Torque | 0.37 to 0.44 ft-lb (0.5 to 0.6 N·m) |
| Terminal Block Wire Size | 24 to 14 AWG (0.2 to 2.1 mm2) |
| Rail | T35 (35mm) DIN Rail per EN50022 |
| Operating Conditions | |
| Operating Temperature Range | -30° to 70°C (-22° to 158°F) |
| Storage Temperature Range | -40° to 85°C (-40° to 185°F) |
| Humidity Range | <95% RH noncondensing |
| Altitude of Operation | 3000 m |
| Compliance Information | |
| US and Canada | CAT III, Pollution Degree 2 For distribution systems up to 347VL-N /600VACL-L |
| CE | CAT III, Pollution Degree 2 For distribution systems up to 300VL-N |
| Dielectric Withstand | Per UL 508, EN61010 |
| Conducted and Radiated Emissions | FCC Part 15 Class B, EN55011/EN61000 Class B (Residential and Light Industrial) |
| Conducted and Radiated Immunity | EN61000 Class A (Heavy Industrial) |
| US and Canada (cULus) | UL508 (Open Type Device)/CSA 22.2 No. 14-05 |
| Europe (CE) | EN61010-1 |
Cliquer sur une catégorie pour voir une sélection d'accessoires compatible avec le Leviton 4OUMR-R12 Outdoor Series 4000 Universal Voltage 3-Phase 3W/4W Modbus Meter Kits, 12" Rogowski Coil CT.
| Measurement Accuracy | |
| Real Power and Energy | IEC 62053-22 Class 0.5S, ANSI C12.20 0.5% |
| Reactive Power and Energy | IEC 62053-23 Class 2, 2% |
| Current | 0.4% (+0.015% per °C deviation from 25°C) from 5% to 100% of range; 0.8% (+0.015% per °C deviation from 25°C) from 1% to 5% of range |
| Voltage | 0.4% (+0.015% per °C deviation from 25°C) from 90VL-N to 600VACL-L |
| Sample Rate | 2520 Samples Per Second |
| Data Update Rate | 1 sec |
| Type of Measurement | True RMS up to the 21st harmonic 60 Hz; One to three phase AC system |
| Input Voltage | |
| Measured AC Voltage | Minimum 90VL-N (156VL-L) for stated accuracy UL Maximums: 600VL-L (347VL-N) CE Maximum: 300VL-N |
| Metering Over-Range | +20% |
| Impedance | 2.5 MΩ L-N /5 MΩ L-L |
| Frequency Range | 45 to 65 Hz |
| Input Current | |
| CT Scaling | Primary: Adjustable from 5 A to 32,000 A |
| Measurement Input Range | 0 to 0.333 VAC or 0 to 1.0 VAC (+20% over-range), rated for use with Class 1 voltage inputs |
| Impedance | 10.6 kΩ (1/3 V mode) or 32.1 kΩ (1 V mode) |
| Control Power | |
| AC | 5VA max.; 90V min. UL Maximums: 600VL-L (347 VL-N ) CE Maximum: 300VL-N |
| DC | 3 W max.; UL and CE: 125 to 300VDC |
| Ride Through Time | 100 msec at 120VAC |
| Output | |
| Alarm Contacts | N.C., static output (30VAC/DC, 100mA max. @ 25°C, derate 0.56mA per °C above 25°C) |
| Real Energy Pulse Contacts | N.O., static output (30VAC/DC, 100mA max. @ 25°C, derate 0.56mA per °C above 25°C) |
| RS-485 Port | 2-wire, 1200 to 38400 baud, Modbus RTU |
| Mechanical | |
| Weight | 0.62 lb (0.28 kg) |
| IP Degree of Protection (IEC 60529) | IP40 front display; IP20 Meter |
| Display Characteristics | Back-lit blue LCD |
| Terminal Block Screw Torque | 0.37 to 0.44 ft-lb (0.5 to 0.6 N·m) |
| Terminal Block Wire Size | 24 to 14 AWG (0.2 to 2.1 mm2) |
| Rail | T35 (35mm) DIN Rail per EN50022 |
| Operating Conditions | |
| Operating Temperature Range | -30° to 70°C (-22° to 158°F) |
| Storage Temperature Range | -40° to 85°C (-40° to 185°F) |
| Humidity Range | <95% RH noncondensing |
| Altitude of Operation | 3000 m |
| Compliance Information | |
| US and Canada | CAT III, Pollution Degree 2 For distribution systems up to 347VL-N /600VACL-L |
| CE | CAT III, Pollution Degree 2 For distribution systems up to 300VL-N |
| Dielectric Withstand | Per UL 508, EN61010 |
| Conducted and Radiated Emissions | FCC Part 15 Class B, EN55011/EN61000 Class B (Residential and Light Industrial) |
| Conducted and Radiated Immunity | EN61000 Class A (Heavy Industrial) |
| US and Canada (cULus) | UL508 (Open Type Device)/CSA 22.2 No. 14-05 |
| Europe (CE) | EN61010-1 |
Cliquer sur une catégorie pour voir une sélection d'accessoires compatible avec le Leviton 4OUMR-R12 Outdoor Series 4000 Universal Voltage 3-Phase 3W/4W Modbus Meter Kits, 12" Rogowski Coil CT.