Kyoritsu Kew Mate 2012R True RMS AC/DC Multimeter, 600V/120A

Modèle: Kew Mate 2012R | No. de commande: KEWKM2012R

Kyoritsu Kew Mate 2012R True RMS AC/DC Multimeter, 600V/120A

Modèle: Kew Mate 2012R | No. de commande: KEWKM2012R

Features thin jaws, perfect to clamp wires even in tight spaces where a normal clamp meter is too big or wires are too short. Has a maximum resolution of 0.01A AC/DC.

Features thin jaws, perfect to clamp wires even in tight spaces where a normal clamp meter is too big or wires are too short. Has a maximum resolution of 0.01A AC/DC.

Discontinué!

Ce produit a été discontinué et n’est plus disponible.
Voici le produit de remplacement direct :

Kyoritsu KM2012RA Multimètre numérique-

Kyoritsu KM2012RA Multimètre numérique

Modèle: KM2012RA

Ce multimètre numérique est équipé pour résister à des tensions allant jusqu'à 3540 V CA pendant 5 secondes.


Kyoritsu Kew Mate 2012R offre

Kyoritsu Kew Mate 2012R Offers

Caractéristiques

  • Insulated and removable caps prevent shortening of IC legs for proving high density component boards
  • One test probe can be fixed to the meter to help get the job done safer and faster
  • Quick one touch DC zero adjustment
  • Electrical and electronic troubleshooting in residential, commercial, and industrial installations
  • Sub-distribution boards, consumer units, final circuits, connection boxes, and control panels
  • Output of a solar panel in photovoltaic installations
  • Servicing of cars, electric forklifts, small electric cars, or trolleys for cleaning, DC motor adjustable speed controllers, golf cars and trolleys, small electric cars and chairlifts for the disabled, work platforms, UPS's, electric scooters and bikes, etc.
  • Accurate True RMS readings of AC current and voltage also in presence of harmonics created by PC's, Inverter, Electronic Ballast for florescent lamps, UPS's, etc

Applications

  • Electrical and electronic troubleshooting in residential, commercial, and industrial installations
  • Sub-distribution boards, consumer units, final circuits, connection boxes, and control panels
  • Output of a solar panel in photovoltaic installations
  • Servicing of cars, electric forklifts, small electric cars, or trolleys for cleaning, DC motor adjustable speed controllers, golf cars and trolleys, small electric cars and chairlifts for the disabled, work platforms, UPS's, electric scooters and bikes, etc.
  • Accurate True RMS readings of AC current and voltage also in presence of harmonics created by PC's, Inverter, Electronic Ballast for florescent lamps, UPS's, etc

Spécifications pour le Kyoritsu Kew Mate 2012R

  RangeAccuracy
DC V 600.0mV/6.000/60.00/600.0V
(Input impedance: approx. 10MΩ)
±1.0%rdg±3dgt
AC V 6.000/60.00/600.0V
(Input impedance: approx.10MΩ)
±1.5%rdg±5dgt (45 to 400Hz)
DC A 60.00/120.0A±2.0%rdg±8dgt (60A)
±2.0%rdg±5dgt (120A)
AC A 60.00/120.0A±2.0%rdg±5dgt (45 to 65Hz)
Ω 600.0Ω/6.000/60.00/600.0kΩ/
6.000/60.00MΩ
±1.0%rdg±5dgt (600Ω/6/60/600kΩ)
±2.0%rdg±5dgt (6MΩ)
±3.0%rdg±5dgt (60MΩ)
Capacitance 400.0nF/4.000/40.00µF±2.5%rdg±10dgt
Frequency AC A 100/400Hz±0.2%rdg±2dgt (100Hz)
±0.1%rdg±1dgt (400Hz)
Frequency DC A 100/1000Hz/10/100/300.0kHz±0.2%rdg±2dgt (100Hz)
±0.1%rdg±1dgt (1000Hz/10/100/300.0kHz)
Frequency Input Sensitivity Current: more than 6A
Voltage: more than 6V (-10kHz)/more than 20V (10k to 300kHz)
Continuity Buzzer Buzzer sounds below 35±25Ω
Diode Test 2V±3.0%rdg±5dgt
Open-loop voltage: approx. 2.7V

Le Kyoritsu Kew Mate 2012R comprend

  • Digital Multimeter
  • 2 x R03 (1.5V) batteries
  • Instruction Manual
  • Digital Multimeter
  • 2 x R03 (1.5V) batteries
  • Instruction Manual

Poser une question sur le Kyoritsu Kew Mate 2012R True RMS AC/DC Multimeter, 600V/120A

Kyoritsu Kew Mate 2012R offre

Kyoritsu Kew Mate 2012R Offers

Caractéristiques

  • Insulated and removable caps prevent shortening of IC legs for proving high density component boards
  • One test probe can be fixed to the meter to help get the job done safer and faster
  • Quick one touch DC zero adjustment
  • Electrical and electronic troubleshooting in residential, commercial, and industrial installations
  • Sub-distribution boards, consumer units, final circuits, connection boxes, and control panels
  • Output of a solar panel in photovoltaic installations
  • Servicing of cars, electric forklifts, small electric cars, or trolleys for cleaning, DC motor adjustable speed controllers, golf cars and trolleys, small electric cars and chairlifts for the disabled, work platforms, UPS's, electric scooters and bikes, etc.
  • Accurate True RMS readings of AC current and voltage also in presence of harmonics created by PC's, Inverter, Electronic Ballast for florescent lamps, UPS's, etc

Applications

  • Electrical and electronic troubleshooting in residential, commercial, and industrial installations
  • Sub-distribution boards, consumer units, final circuits, connection boxes, and control panels
  • Output of a solar panel in photovoltaic installations
  • Servicing of cars, electric forklifts, small electric cars, or trolleys for cleaning, DC motor adjustable speed controllers, golf cars and trolleys, small electric cars and chairlifts for the disabled, work platforms, UPS's, electric scooters and bikes, etc.
  • Accurate True RMS readings of AC current and voltage also in presence of harmonics created by PC's, Inverter, Electronic Ballast for florescent lamps, UPS's, etc

Spécifications pour le Kyoritsu Kew Mate 2012R

  RangeAccuracy
DC V 600.0mV/6.000/60.00/600.0V
(Input impedance: approx. 10MΩ)
±1.0%rdg±3dgt
AC V 6.000/60.00/600.0V
(Input impedance: approx.10MΩ)
±1.5%rdg±5dgt (45 to 400Hz)
DC A 60.00/120.0A±2.0%rdg±8dgt (60A)
±2.0%rdg±5dgt (120A)
AC A 60.00/120.0A±2.0%rdg±5dgt (45 to 65Hz)
Ω 600.0Ω/6.000/60.00/600.0kΩ/
6.000/60.00MΩ
±1.0%rdg±5dgt (600Ω/6/60/600kΩ)
±2.0%rdg±5dgt (6MΩ)
±3.0%rdg±5dgt (60MΩ)
Capacitance 400.0nF/4.000/40.00µF±2.5%rdg±10dgt
Frequency AC A 100/400Hz±0.2%rdg±2dgt (100Hz)
±0.1%rdg±1dgt (400Hz)
Frequency DC A 100/1000Hz/10/100/300.0kHz±0.2%rdg±2dgt (100Hz)
±0.1%rdg±1dgt (1000Hz/10/100/300.0kHz)
Frequency Input Sensitivity Current: more than 6A
Voltage: more than 6V (-10kHz)/more than 20V (10k to 300kHz)
Continuity Buzzer Buzzer sounds below 35±25Ω
Diode Test 2V±3.0%rdg±5dgt
Open-loop voltage: approx. 2.7V

Le Kyoritsu Kew Mate 2012R comprend

  • Digital Multimeter
  • 2 x R03 (1.5V) batteries
  • Instruction Manual
  • Digital Multimeter
  • 2 x R03 (1.5V) batteries
  • Instruction Manual

Poser une question sur le Kyoritsu Kew Mate 2012R True RMS AC/DC Multimeter, 600V/120A

Plus de produits Kyoritsu