Kyoritsu KEW 8148 Current Transformer

Modèle: 8148 | No. de commande: KEW8148

Kyoritsu KEW 8148 Current Transformer

Modèle: 8148 | No. de commande: KEW8148

Compatible with the 5010, 5020, and 5050 loggers and 6310 and 6315 power meters, this clamp sensor provides easy and safe installations in existing facilities without errors. In addition, this leakage/load current detection type clamp sensor features a rated current of 100 A AC and fits conductors 2.7" (68 mm) in diameter.

Compatible with the 5010, 5020, and 5050 loggers and 6310 and 6315 power meters, this clamp sensor provides easy and safe installations in existing facilities without errors. In addition, this leakage/load current detection type clamp sensor features a rated current of 100 A AC and fits conductors 2.7" (68 mm) in diameter.

Prix spécial $510.69 CAD
Prix régulier $587.00 CAD
Disponibilité 5 à 6 semaines
Quantité

Spécifications pour le Kyoritsu 8148

Rated Current 100 A AC
Output Voltage 5000 mV/100 A AC (50 mV/A AC)
Accuracy 0 to 80 A
±1% rdg ±0.1 mV (50/60 Hz)
±2% rdg ±0.2 mV (40 Hz to 1 kHz)

80 to 100 A
±5% rdg (50/60 Hz)
±10% rdg (45 Hz to 1 kHz)
Output Connector: MINI DIN 6-pin
Impedance: Approximately 60 Ω
Applicable Standards IEC 61010-1, IEC 61010-2-032 CAT III 300 V pollution degree 2, IEC 61326
Operating Temperature/Humidity Range 32 to 122°F (0 to 50°C), less than 85% RH (without condensation)
Conductor Size Ø2.7" (Ø68 mm)
Cable Length Approximately 6.56' (2 m)
Dimensions 7.3 x 5.1 x 2.1" (186 x 129 x 53 mm)
Weight Approximately 1.12 lbs (510 g)

Le Kyoritsu 8148 comprend

  • Clamp Sensor
  • Cable Marker
  • Carrying Case
  • Instruction Manual

Poser une question sur le Kyoritsu KEW 8148 Current Transformer

Spécifications pour le Kyoritsu 8148

Rated Current 100 A AC
Output Voltage 5000 mV/100 A AC (50 mV/A AC)
Accuracy 0 to 80 A
±1% rdg ±0.1 mV (50/60 Hz)
±2% rdg ±0.2 mV (40 Hz to 1 kHz)

80 to 100 A
±5% rdg (50/60 Hz)
±10% rdg (45 Hz to 1 kHz)
Output Connector: MINI DIN 6-pin
Impedance: Approximately 60 Ω
Applicable Standards IEC 61010-1, IEC 61010-2-032 CAT III 300 V pollution degree 2, IEC 61326
Operating Temperature/Humidity Range 32 to 122°F (0 to 50°C), less than 85% RH (without condensation)
Conductor Size Ø2.7" (Ø68 mm)
Cable Length Approximately 6.56' (2 m)
Dimensions 7.3 x 5.1 x 2.1" (186 x 129 x 53 mm)
Weight Approximately 1.12 lbs (510 g)

Le Kyoritsu 8148 comprend

  • Clamp Sensor
  • Cable Marker
  • Carrying Case
  • Instruction Manual

Poser une question sur le Kyoritsu KEW 8148 Current Transformer

Plus de produits Kyoritsu