Kyoritsu 2434 Leakage Clamp Meter

Modèle: 2434 | No. de commande: KEW2434

Kyoritsu 2434 Leakage Clamp Meter

Modèle: 2434 | No. de commande: KEW2434

Least affected by external stray magnetic field. The 20mA AC max. in proximity to a 15 mm diameter conductor could carry 100A AC.

Least affected by external stray magnetic field. The 20mA AC max. in proximity to a 15 mm diameter conductor could carry 100A AC.

Prix spécial $609.00 CAD
Prix régulier $700.00 CAD
Disponibilité 5 à 6 semaines
Quantité

Traceable Calibration Certificate Icon

Certificat d’étalonnage de traçabilité pour votre KEW2434

Traceable Calibration Certificate Icon

Certificat d’étalonnage de traçabilité pour votre KEW2434

Kyoritsu 2434 Offers

Features

  • Frequency selector switch to eliminate the effect of harmonics
  • 20mA AC max. in proximity to a 15mm diameter conductor carrying 100A AC
  • Least affected by external stray magnetic field: 20mA AC max. in proximity to a 15 mm diameter conductor 100A AC
  • Data hold function
  • Sleep function to save battery
  • Designed to international safety standards IEC61010-1 CAT.II 300V

Kyoritsu 2434 Specifications

AC
Measuring Ranges 400mA: 0 to 399.9mA
4A: 0 to 3.999A
100A: 0 to 100.0A
Accuracy 50/60Hz: ±2.0%rdg ±4dgt
40 to 400Hz: ±3.0%rdg ±5dgt
General Specifications
Maximum Circuit Voltage Between Line/Neutral: 600V AC/DC
Against Earth: 300V AC/DC
Conductor Size Approx. Ø28mm
Safety Standards IEC 61010-1 CAT. 300V
IEC 61010-2-032
IEC 61326-1
Effect of External Stray Magnetic Field 20mA AC approx. in proximity to a 15mm diameter conductor carrying 100A AC
Withstand Voltage 3700V AC for 1 minute
Response Time Approx. 2 seconds
Power Source 2 x R03 or equivalent DC 1.5V batteries
Dimensions 169 x 75 x 40 mm
Weight Approx. 210 g
Cliquer ici pour toutes les spécifications du Kyoritsu 2434

What's included with the Kyoritsu 2434

  • Leakage Clamp Meter
  • Carrying Case
  • 2 x 1.5V R03 Battery
  • Instruction Manual

Poser une question sur le Kyoritsu 2434 Leakage Clamp Meter

Kyoritsu 2434 Offers

Features

  • Frequency selector switch to eliminate the effect of harmonics
  • 20mA AC max. in proximity to a 15mm diameter conductor carrying 100A AC
  • Least affected by external stray magnetic field: 20mA AC max. in proximity to a 15 mm diameter conductor 100A AC
  • Data hold function
  • Sleep function to save battery
  • Designed to international safety standards IEC61010-1 CAT.II 300V

Kyoritsu 2434 Specifications

AC
Measuring Ranges 400mA: 0 to 399.9mA
4A: 0 to 3.999A
100A: 0 to 100.0A
Accuracy 50/60Hz: ±2.0%rdg ±4dgt
40 to 400Hz: ±3.0%rdg ±5dgt
General Specifications
Maximum Circuit Voltage Between Line/Neutral: 600V AC/DC
Against Earth: 300V AC/DC
Conductor Size Approx. Ø28mm
Safety Standards IEC 61010-1 CAT. 300V
IEC 61010-2-032
IEC 61326-1
Effect of External Stray Magnetic Field 20mA AC approx. in proximity to a 15mm diameter conductor carrying 100A AC
Withstand Voltage 3700V AC for 1 minute
Response Time Approx. 2 seconds
Power Source 2 x R03 or equivalent DC 1.5V batteries
Dimensions 169 x 75 x 40 mm
Weight Approx. 210 g
Cliquer ici pour toutes les spécifications du Kyoritsu 2434

What's included with the Kyoritsu 2434

  • Leakage Clamp Meter
  • Carrying Case
  • 2 x 1.5V R03 Battery
  • Instruction Manual

Poser une question sur le Kyoritsu 2434 Leakage Clamp Meter

Plus de produits Kyoritsu