Ideal for measuring capacitance, voltage, microamps, circuit continuity, resistance, and temperature, this clamp meter features k-type thermocouples. In addition, this meter comes with silicone test leads, back probes, two temperature probes, alligator clips, a zippered pouch, and 4 AAA batteries.
Ideal for measuring capacitance, voltage, microamps, circuit continuity, resistance, and temperature, this clamp meter features k-type thermocouples. In addition, this meter comes with silicone test leads, back probes, two temperature probes, alligator clips, a zippered pouch, and 4 AAA batteries.
Caractéristiques
Applications
| AC Amps Measurement - Jaw Input | Range: 60 to 600 A Resolution: 0.01 to 0.1 A Accuracy: ±2% + 8dgts Overload protection: 600 V RMS 45 to 400 Hz True RMS Minimum current for clamp measurement: 0.3 A |
| DC Amps Measurement - Test Lead Input | Range: 600 to 2000 μA Resolution: 0.1 to 1 μA Accuracy: ±1.2% + 3dgts Overload protection: 600 V RMS |
| AC Amps Measurement - Test Lead Input | Range: 600 to 2000 μA Resolution: 0.1 to 1 μA Accuracy: ±2% + 5dgts to ±1.5% + 5dgts Overload protection: 600 V RMS 45 to 400 Hz True RMS |
| DC Volts Measurement | Range: 600 mV 6 V 60 V 600 V 1000 V Resolution: 0.1 mV 0.001 V 0.01 V 0.1 V 1 V Accuracy: ±0.5% + 4dgts ±0.8% + 10dgts Overload protection: 1000 V RMS |
| AC Volts Measurement | Range: 600 mV 6 V 60 V 600 V 750 V Resolution: 0.1 mV 0.001 V 0.01 V 0.1 V 1 V Accuracy: ±0.8% + 5dgts Overload protection: 750 V RMS 45 to 400 Hz True RMS |
| Ohms Measurement | Range: 600 Ω 6 kΩ 60 kΩ 600 kΩ 6 MΩ 60 MΩ Resolution: 0.1 Ω 0.001 kΩ 0.01 kΩ 0.1 kΩ 0.001 MΩ 0.01 MΩ Accuracy: ±1% + 4dgts ±2% + 4dgts Overload protection: 600 V RMS |
| Diode Test | Range: 6 V Resolution: <3 V DC Test current (typical): 0.25 mA Overload protection: 600 V RMS |
| Capacitance Measurement | Range: 60 nF 600 nF 6 μF 60 μF 600 μF 6000 μF Resolution: 0.01 nF 0.1 nF 0.001 μF 0.01 μF 1 μF Accuracy: 3.5% + 6dgts Overload protection: 600 V RMS |
| Temperature Measurement | Range: -328 to 999°F (-200 to 999°C) 1000 to 2462°F (1000 to 1350°C) Resolution: 0.1°F (0.1°C) Accuracy: ±[1% +3.6°F (1% +2°C)] ±[1% +3°F (1% +2°C)] Overload protection: 30 V RMS Sensor: K type thermocouple, sensor accuracy not included |
| Frequency Measurement - Test Lead Input | Range: 99.99 Hz 999.9 HzF 9.999 kHz 99.99 kHz Resolution: 0.01 Hz 0.1 Hz 0.001 kHz 0.01 kHz Accuracy: 0.1% + 4dgets Overload protection: 1000 V RMS Minimum frequency: 0.5 Hz, DC V offset should be zero Sensitivity: >10% of each AC volt range except 4 V (>20%) range only |
| Duty (5%) Cycle Measurement | Range: 1 to 99% Resolution: ±(0.2% per kHz +0.1% +5 dgts) Overload protection: 1000 V RMS |
| Audible Continuity Measurement | Range: Open circuit voltage <0.64 V: <40 Ω Overload protection: 600 V RMS |
| AC Amps Measurement - Jaw Input | Range: 60 to 600 A Resolution: 0.01 to 0.1 A Accuracy: ±2% + 8dgts Overload protection: 600 V RMS 45 to 400 Hz True RMS Minimum current for clamp measurement: 0.3 A |
| DC Amps Measurement - Test Lead Input | Range: 600 to 2000 μA Resolution: 0.1 to 1 μA Accuracy: ±1.2% + 3dgts Overload protection: 600 V RMS |
| AC Amps Measurement - Test Lead Input | Range: 600 to 2000 μA Resolution: 0.1 to 1 μA Accuracy: ±2% + 5dgts to ±1.5% + 5dgts Overload protection: 600 V RMS 45 to 400 Hz True RMS |
| DC Volts Measurement | Range: 600 mV 6 V 60 V 600 V 1000 V Resolution: 0.1 mV 0.001 V 0.01 V 0.1 V 1 V Accuracy: ±0.5% + 4dgts ±0.8% + 10dgts Overload protection: 1000 V RMS |
| AC Volts Measurement | Range: 600 mV 6 V 60 V 600 V 750 V Resolution: 0.1 mV 0.001 V 0.01 V 0.1 V 1 V Accuracy: ±0.8% + 5dgts Overload protection: 750 V RMS 45 to 400 Hz True RMS |
| Ohms Measurement | Range: 600 Ω 6 kΩ 60 kΩ 600 kΩ 6 MΩ 60 MΩ Resolution: 0.1 Ω 0.001 kΩ 0.01 kΩ 0.1 kΩ 0.001 MΩ 0.01 MΩ Accuracy: ±1% + 4dgts ±2% + 4dgts Overload protection: 600 V RMS |
| Diode Test | Range: 6 V Resolution: <3 V DC Test current (typical): 0.25 mA Overload protection: 600 V RMS |
| Capacitance Measurement | Range: 60 nF 600 nF 6 μF 60 μF 600 μF 6000 μF Resolution: 0.01 nF 0.1 nF 0.001 μF 0.01 μF 1 μF Accuracy: 3.5% + 6dgts Overload protection: 600 V RMS |
| Temperature Measurement | Range: -328 to 999°F (-200 to 999°C) 1000 to 2462°F (1000 to 1350°C) Resolution: 0.1°F (0.1°C) Accuracy: ±[1% +3.6°F (1% +2°C)] ±[1% +3°F (1% +2°C)] Overload protection: 30 V RMS Sensor: K type thermocouple, sensor accuracy not included |
| Frequency Measurement - Test Lead Input | Range: 99.99 Hz 999.9 HzF 9.999 kHz 99.99 kHz Resolution: 0.01 Hz 0.1 Hz 0.001 kHz 0.01 kHz Accuracy: 0.1% + 4dgets Overload protection: 1000 V RMS Minimum frequency: 0.5 Hz, DC V offset should be zero Sensitivity: >10% of each AC volt range except 4 V (>20%) range only |
| Duty (5%) Cycle Measurement | Range: 1 to 99% Resolution: ±(0.2% per kHz +0.1% +5 dgts) Overload protection: 1000 V RMS |
| Audible Continuity Measurement | Range: Open circuit voltage <0.64 V: <40 Ω Overload protection: 600 V RMS |