Kane KANE589 True-RMS Dual Display Clamp Meter with DC amps, differential temperature

Modèle: KANE589

Kane KANE589 True-RMS Dual Display Clamp Meter with DC amps, differential temperature

Modèle: KANE589

Ideal for measuring capacitance, voltage, microamps, circuit continuity, resistance, and temperature, this clamp meter features k-type thermocouples. In addition, this meter comes with silicone test leads, back probes, two temperature probes, alligator clips, a zippered pouch, and 4 AAA batteries.

Ideal for measuring capacitance, voltage, microamps, circuit continuity, resistance, and temperature, this clamp meter features k-type thermocouples. In addition, this meter comes with silicone test leads, back probes, two temperature probes, alligator clips, a zippered pouch, and 4 AAA batteries.

Prix spécial $384.11 CAD
Prix régulier $391.95 CAD
Disponibilité 1 à 2 semaines
Quantité

Kane KANE589 offre

Caractéristiques

  • TRMS
  • Backlit dual display and worklight
  • Minimum/maximum/hold
  • Test lead storage
  • Visible high-voltage alert
  • Easy access battery cover latches
  • Raised molding
  • Auto and manual ranging
  • Auto power off
  • Low battery indicator
  • Auto volts and amp selection
  • Over-molded grip
  • Peak hold
  • Auto calibration
  • Input cack lock
  • Frequency/duty cycle
  • Audible continuity
  • Diode test
  • Non-contact voltage detection
  • LRA inrush
  • Low Z (impedance)

Applications

  • Measure capacitance, voltage, circuit continuity, resistance, temperature via k-type thermocouples
  • Check system board and live wires
  • Flame sensing
  • Circuits in molex plugs, and diode malfunctions.

Spécifications pour le Kane KANE589

AC Amps Measurement - Jaw Input Range: 60 to 600 A
Resolution: 0.01 to 0.1 A
Accuracy: ±2% + 8dgts
Overload protection: 600 V RMS
45 to 400 Hz True RMS
Minimum current for clamp measurement: 0.3 A
DC Amps Measurement - Test Lead Input Range: 600 to 2000 μA
Resolution: 0.1 to 1 μA
Accuracy: ±1.2% + 3dgts
Overload protection: 600 V RMS
AC Amps Measurement - Test Lead Input Range: 600 to 2000 μA
Resolution: 0.1 to 1 μA
Accuracy: ±2% + 5dgts to ±1.5% + 5dgts
Overload protection: 600 V RMS
45 to 400 Hz True RMS
DC Volts Measurement Range:
600 mV
6 V
60 V
600 V
1000 V

Resolution:
0.1 mV
0.001 V
0.01 V
0.1 V
1 V

Accuracy:
±0.5% + 4dgts
±0.8% + 10dgts
Overload protection: 1000 V RMS
AC Volts Measurement Range:
600 mV
6 V
60 V
600 V
750 V

Resolution:
0.1 mV
0.001 V
0.01 V
0.1 V
1 V

Accuracy:
±0.8% + 5dgts
Overload protection: 750 V RMS
45 to 400 Hz True RMS
Ohms Measurement Range:
600 Ω
6 kΩ
60 kΩ
600 kΩ
6 MΩ
60 MΩ

Resolution:
0.1 Ω
0.001 kΩ
0.01 kΩ
0.1 kΩ
0.001 MΩ
0.01 MΩ

Accuracy:
±1% + 4dgts
±2% + 4dgts
Overload protection: 600 V RMS
Diode Test Range: 6 V
Resolution: <3 V DC
Test current (typical): 0.25 mA
Overload protection: 600 V RMS
Capacitance Measurement Range:
60 nF
600 nF
6 μF
60 μF
600 μF
6000 μF

Resolution:
0.01 nF
0.1 nF
0.001 μF
0.01 μF
1 μF

Accuracy: 3.5% + 6dgts
Overload protection: 600 V RMS
Temperature Measurement Range:
-328 to 999°F (-200 to 999°C)
1000 to 2462°F (1000 to 1350°C)

Resolution:
0.1°F (0.1°C)

Accuracy:
±[1% +3.6°F (1% +2°C)]
±[1% +3°F (1% +2°C)]

Overload protection: 30 V RMS
Sensor: K type thermocouple, sensor accuracy not included
Frequency Measurement - Test Lead Input Range:
99.99 Hz
999.9 HzF
9.999 kHz
99.99 kHz

Resolution:
0.01 Hz
0.1 Hz
0.001 kHz
0.01 kHz

Accuracy: 0.1% + 4dgets
Overload protection: 1000 V RMS
Minimum frequency: 0.5 Hz, DC V offset should be zero
Sensitivity: >10% of each AC volt range except 4 V (>20%) range only
Duty (5%) Cycle Measurement Range: 1 to 99%
Resolution: ±(0.2% per kHz +0.1% +5 dgts)
Overload protection: 1000 V RMS
Audible Continuity Measurement Range: Open circuit voltage <0.64 V: <40 Ω
Overload protection: 600 V RMS

Le Kane KANE589 comprend

  • Clamp Meter
  • Test Leads
  • Alligator Clips
  • 2 x Temperature Probes
  • Back Probes
  • Zippered Pouch
  • 4 x AAA Batteries
  • Manual
  • One-Year Warranty

Poser une question sur le Kane KANE589 True-RMS Dual Display Clamp Meter with DC amps, differential temperature

Kane KANE589 offre

Caractéristiques

  • TRMS
  • Backlit dual display and worklight
  • Minimum/maximum/hold
  • Test lead storage
  • Visible high-voltage alert
  • Easy access battery cover latches
  • Raised molding
  • Auto and manual ranging
  • Auto power off
  • Low battery indicator
  • Auto volts and amp selection
  • Over-molded grip
  • Peak hold
  • Auto calibration
  • Input cack lock
  • Frequency/duty cycle
  • Audible continuity
  • Diode test
  • Non-contact voltage detection
  • LRA inrush
  • Low Z (impedance)

Applications

  • Measure capacitance, voltage, circuit continuity, resistance, temperature via k-type thermocouples
  • Check system board and live wires
  • Flame sensing
  • Circuits in molex plugs, and diode malfunctions.

Spécifications pour le Kane KANE589

AC Amps Measurement - Jaw Input Range: 60 to 600 A
Resolution: 0.01 to 0.1 A
Accuracy: ±2% + 8dgts
Overload protection: 600 V RMS
45 to 400 Hz True RMS
Minimum current for clamp measurement: 0.3 A
DC Amps Measurement - Test Lead Input Range: 600 to 2000 μA
Resolution: 0.1 to 1 μA
Accuracy: ±1.2% + 3dgts
Overload protection: 600 V RMS
AC Amps Measurement - Test Lead Input Range: 600 to 2000 μA
Resolution: 0.1 to 1 μA
Accuracy: ±2% + 5dgts to ±1.5% + 5dgts
Overload protection: 600 V RMS
45 to 400 Hz True RMS
DC Volts Measurement Range:
600 mV
6 V
60 V
600 V
1000 V

Resolution:
0.1 mV
0.001 V
0.01 V
0.1 V
1 V

Accuracy:
±0.5% + 4dgts
±0.8% + 10dgts
Overload protection: 1000 V RMS
AC Volts Measurement Range:
600 mV
6 V
60 V
600 V
750 V

Resolution:
0.1 mV
0.001 V
0.01 V
0.1 V
1 V

Accuracy:
±0.8% + 5dgts
Overload protection: 750 V RMS
45 to 400 Hz True RMS
Ohms Measurement Range:
600 Ω
6 kΩ
60 kΩ
600 kΩ
6 MΩ
60 MΩ

Resolution:
0.1 Ω
0.001 kΩ
0.01 kΩ
0.1 kΩ
0.001 MΩ
0.01 MΩ

Accuracy:
±1% + 4dgts
±2% + 4dgts
Overload protection: 600 V RMS
Diode Test Range: 6 V
Resolution: <3 V DC
Test current (typical): 0.25 mA
Overload protection: 600 V RMS
Capacitance Measurement Range:
60 nF
600 nF
6 μF
60 μF
600 μF
6000 μF

Resolution:
0.01 nF
0.1 nF
0.001 μF
0.01 μF
1 μF

Accuracy: 3.5% + 6dgts
Overload protection: 600 V RMS
Temperature Measurement Range:
-328 to 999°F (-200 to 999°C)
1000 to 2462°F (1000 to 1350°C)

Resolution:
0.1°F (0.1°C)

Accuracy:
±[1% +3.6°F (1% +2°C)]
±[1% +3°F (1% +2°C)]

Overload protection: 30 V RMS
Sensor: K type thermocouple, sensor accuracy not included
Frequency Measurement - Test Lead Input Range:
99.99 Hz
999.9 HzF
9.999 kHz
99.99 kHz

Resolution:
0.01 Hz
0.1 Hz
0.001 kHz
0.01 kHz

Accuracy: 0.1% + 4dgets
Overload protection: 1000 V RMS
Minimum frequency: 0.5 Hz, DC V offset should be zero
Sensitivity: >10% of each AC volt range except 4 V (>20%) range only
Duty (5%) Cycle Measurement Range: 1 to 99%
Resolution: ±(0.2% per kHz +0.1% +5 dgts)
Overload protection: 1000 V RMS
Audible Continuity Measurement Range: Open circuit voltage <0.64 V: <40 Ω
Overload protection: 600 V RMS

Le Kane KANE589 comprend

  • Clamp Meter
  • Test Leads
  • Alligator Clips
  • 2 x Temperature Probes
  • Back Probes
  • Zippered Pouch
  • 4 x AAA Batteries
  • Manual
  • One-Year Warranty

Poser une question sur le Kane KANE589 True-RMS Dual Display Clamp Meter with DC amps, differential temperature