Hioki MR8905 2-Channel Memory HiCorder Analog Module, 1,000VDC

Modèle: MR8905

Hioki MR8905 2-Channel Memory HiCorder Analog Module, 1,000VDC

Modèle: MR8905

Safely monitor high-voltage devices with this analog module. The unit can handle 700VAC and 1,000VDC currents.

Safely monitor high-voltage devices with this analog module. The unit can handle 700VAC and 1,000VDC currents.

Prix spécial $2683.92 CAD
Prix régulier $3376.00 CAD
Disponibilité 4 à 5 semaines
Quantité

Hioki MR8905 offre

Designed for use with the Memory HiCorder MR8875 model (sold separately), the Hioki MR8905 2-Channel Memory HiCorder Analog Module is ideal for monitoring high-voltage systems. The module is built to withstand 700 VAC and 1,000 VDC inputs, making it great for testing UPS power supplies and commercial power supply transformers.

Caractéristiques

  • Compatible with the Memory HiCorder MR8875 model (sold separately)
  • Designed for primary and secondary measurements of UPS power supplies and commercial power supply transformers
  • Also ideal for recording primary and secondary waveforms of inverters
  • Can be used to measure high-voltage power supply lines, such as 380 V and 480 V systems
  • Withstands direct high-voltage inputs of 1,000 VDC or 700 VAC power

Spécifications pour le Hioki MR8905

Number of Channels 2 (switchable between instantaneous value and AC RMS value)
Input Connectors Banana
Measurement Range 500 mV to 50 V/div, 7 ranges, full scale: 20 div, *The maximum displayable AC voltage is 700 Vrms when using 1/2 compression of the vertical axis
Low-Pass Filter 5/50/500/5 kHz, off
Resolution 1/1,250 of measurement range (using 16-bit A/D converter)
Highest Sampling Rate 500 kS/s (simultaneous sampling across 2 channels)
Accuracy ±0.5% f.s. (with 5 Hz filter ON)
RMS Accuracy ±1.5% f.s. (30 Hz up to, but not including, 1 kHz, sine wave input), ±3% f.s. (1 kHz up to 10 kHz, sine wave input)
RMS Response Time 300 ms (filter off, rising from 0 to 90% f.s.), 600 ms (filter off, falling from 100 to 10% f.s.)
Frequency Characteristics DC to 100 kHz (-3 dB)
Input Coupling DC/AC-RMS/Ground
Maximum Allowable Input 1,000 VDC, 700 VAC
Maximum Rated Voltage to Earth CAT II 1000 VAC/VDC, CAT III 600 VAC/VDC
CE Compliant Yes
Product Length 5.96" (151.5 mm)
Product Width 4.7" (119.5 mm)
Product Height 0.74" (18.8 mm)
Product Weight 6.5 oz (185 g)
Manufacturer Warranty 3 years

Le Hioki MR8905 comprend

  • Hioki MR8905 2-Channel Memory HiCorder Analog Module, 1,000VDC

Poser une question sur le Hioki MR8905 2-Channel Memory HiCorder Analog Module, 1,000VDC

Hioki MR8905 offre

Designed for use with the Memory HiCorder MR8875 model (sold separately), the Hioki MR8905 2-Channel Memory HiCorder Analog Module is ideal for monitoring high-voltage systems. The module is built to withstand 700 VAC and 1,000 VDC inputs, making it great for testing UPS power supplies and commercial power supply transformers.

Caractéristiques

  • Compatible with the Memory HiCorder MR8875 model (sold separately)
  • Designed for primary and secondary measurements of UPS power supplies and commercial power supply transformers
  • Also ideal for recording primary and secondary waveforms of inverters
  • Can be used to measure high-voltage power supply lines, such as 380 V and 480 V systems
  • Withstands direct high-voltage inputs of 1,000 VDC or 700 VAC power

Spécifications pour le Hioki MR8905

Number of Channels 2 (switchable between instantaneous value and AC RMS value)
Input Connectors Banana
Measurement Range 500 mV to 50 V/div, 7 ranges, full scale: 20 div, *The maximum displayable AC voltage is 700 Vrms when using 1/2 compression of the vertical axis
Low-Pass Filter 5/50/500/5 kHz, off
Resolution 1/1,250 of measurement range (using 16-bit A/D converter)
Highest Sampling Rate 500 kS/s (simultaneous sampling across 2 channels)
Accuracy ±0.5% f.s. (with 5 Hz filter ON)
RMS Accuracy ±1.5% f.s. (30 Hz up to, but not including, 1 kHz, sine wave input), ±3% f.s. (1 kHz up to 10 kHz, sine wave input)
RMS Response Time 300 ms (filter off, rising from 0 to 90% f.s.), 600 ms (filter off, falling from 100 to 10% f.s.)
Frequency Characteristics DC to 100 kHz (-3 dB)
Input Coupling DC/AC-RMS/Ground
Maximum Allowable Input 1,000 VDC, 700 VAC
Maximum Rated Voltage to Earth CAT II 1000 VAC/VDC, CAT III 600 VAC/VDC
CE Compliant Yes
Product Length 5.96" (151.5 mm)
Product Width 4.7" (119.5 mm)
Product Height 0.74" (18.8 mm)
Product Weight 6.5 oz (185 g)