This AC sensor is built to handle 20 and 200A currents, as well as frequencies from 1Hz to 100kHz. With a clamp-on design, the sensor offers simple attachment to devices.
This AC sensor is built to handle 20 and 200A currents, as well as frequencies from 1Hz to 100kHz. With a clamp-on design, the sensor offers simple attachment to devices.
Discontinué!
Ce produit a été discontinué et n’est plus disponible. Il n’y a pas de produit de remplacement direct. Ne vous inquiétez pas, nous avons quelques options pour vous aider à trouver ce dont vous avez besoin:
Visitez notre catégorie Current Adapters pour trouver des produits similaires.
Ou nous ferons une recherche et vous aiderons à trouver ce dont vous avez besoin:
Connect this Hioki 9272-10 Clamp-On AC Sensor to your desired device thanks to the clamp-on attachment. This sensor is great for measuring harmonic analysis, FFT analysis and waveform monitoring with compatible power meters, Memory HiCorders and high-performance oscilloscopes (sold separately).
Caractéristiques
| Rated Current | 20A AC, 200A AC (selectable) |
| Maximum Allowable Input | 50Arms (at 20A range), 300Arms (at 200A range) |
| Frequency | 1Hz (±2% of reading, ±0.1% full scale) to 100kHz (±30% of reading, ±0.1% full scale) |
| Amplitude Accuracy | ±0.3% reading, ±0.01% full scale |
| Phase Accuracy | ±0.2° (45 to 66Hz) |
| Output Voltage | 2V/20A rated current range, 2V/200A rated current range (voltage output with the sensor unit, use with a device having a 1MΩ input resistance or higher) |
| Maximum Rated Voltage to Earth | 600Vrms (Cat III) |
| Core Diameter | φ1.81in (46mm) |
| Power Supply | ±11 to ±15VDC (power supplied via the sensor unit, which supports 100 to 240VAC) |
| Terminals | PL23 |
| CE Compliant | Yes |
| Product Length | 1.38in (35mm) unit, 9.84ft (3m) cord |
| Product Width | 3.07in (78mm) |
| Product Height | 7.4in (188mm) |
| Product Weight | 15.2oz (430g) |
| Rated Current | 20A AC, 200A AC (selectable) |
| Maximum Allowable Input | 50Arms (at 20A range), 300Arms (at 200A range) |
| Frequency | 1Hz (±2% of reading, ±0.1% full scale) to 100kHz (±30% of reading, ±0.1% full scale) |
| Amplitude Accuracy | ±0.3% reading, ±0.01% full scale |
| Phase Accuracy | ±0.2° (45 to 66Hz) |
| Output Voltage | 2V/20A rated current range, 2V/200A rated current range (voltage output with the sensor unit, use with a device having a 1MΩ input resistance or higher) |
| Maximum Rated Voltage to Earth | 600Vrms (Cat III) |
| Core Diameter | φ1.81in (46mm) |
| Power Supply | ±11 to ±15VDC (power supplied via the sensor unit, which supports 100 to 240VAC) |
| Terminals | PL23 |
| CE Compliant | Yes |
| Product Length | 1.38in (35mm) unit, 9.84ft (3m) cord |
| Product Width | 3.07in (78mm) |
| Product Height | 7.4in (188mm) |
| Product Weight | 15.2oz (430g) |