Hioki 8970 Memory HiCorder Frequency Unit, 50/60/400Hz

Modèle: 8970

Hioki 8970 Memory HiCorder Frequency Unit, 50/60/400Hz

Modèle: 8970

Connect this frequency unit to your Memory HiCorder to measure line frequency, motor rotation and pulses. The unit is capable of handling up to 300VAC/VDC from the Earth.

Connect this frequency unit to your Memory HiCorder to measure line frequency, motor rotation and pulses. The unit is capable of handling up to 300VAC/VDC from the Earth.

Prix spécial $2625.09 CAD
Prix régulier $3302.00 CAD
Disponibilité 2 à 3 semaines
Quantité

Hioki 8970 offre

Monitor the performance of commercial power lines with this Hioki 8970 Memory HiCorder Frequency Unit. The unit is built to measure motor rotation, duty ratio, pulse width, pulse integration and frequency fluctuations. The unit's isolated BNC inputs can handle up to 300 VAC/VDC from the Earth, and is compatible with select Memory HiCorder models.

Caractéristiques

  • Measures commercial power for the fluctuation of power line frequency
  • Allows direct input of class line up to 200 V
  • Delivers pulse counting for the encoder
  • Measures motor rotation, pulse integration, duty ratio and pulse width
  • Boasts 2 isolated inputs that can handle up to 300 VAC/VDC from the Earth
  • Compatible with Memory HiCorder MR6000, MR8847A, MR8827 and other models (sold separately)

Spécifications pour le Hioki 8970

Number of Channels 2
Measurement Functions Voltage input based frequency measurement, rotation, power frequency, integration, pulse duty ratio, pulse width
Input Connectors Isolated BNC
Maximum Rated Voltage to Earth 300 VAC/VDC
Power Frequency Mode Range: 50 Hz (40 to 60 Hz), 60 Hz (50 to 70 Hz), 400 Hz (390 to 410 Hz), 3 settings, Accuracy: ±0.03 Hz (exclude 400 Hz range), ±0.1 Hz (400 Hz range)
Frequency Mode Range: DC to 100 kHz (minimum pulse width 2 μs), 1 Hz/div to 5 kHz/div (full scale= 20 div), 8 settings, Accuracy: ±0.1% f.s. (exclude 5 kHz/div), ±0.7% f.s. (at 5 kHz/div)
Rotation Mode Range: 0 to 2 million rotations/minute (minimum pulse width 2 μs), 100 (r/min)/div to 100k (r/min)/div (full scale= 20 div), 7 settings, Accuracy: ±0.1% f.s. (excluding 100k (r/min)/div), ±0.7% f.s. (at 100k (r/min)/div)
Integration Mode Range Range: 2k counts/div to 1M counts/div, 6 settings, Accuracy: ±range/2000
Duty Ratio Mode Range: 10 Hz to 100 kHz (minimum pulse width 2 μs), 5%/div (full scale=20 div), Accuracy: ±1% (10 Hz to 10 kHz), ±4% (10 kHz to 100 kHz)
Pulse Width Mode Range: 2 μs to 2sec, 500 μs/div to 100 ms/dv (full scale=20 div), Accuracy: ±0.1% f.s
Other Functions Slope, level, hold, smoothing, low-pass filter, switchable DC/AC input coupling, frequency dividing, integration over-range keep/return
Input Voltage ±10 to ±400 V, 6 settings
Threshold Level Selectable
CE Compliant Yes
Product Length 7.74" (196.5 mm)
Product Width 4.17" (106 mm)
Product Height 0.78" (19.8 mm)
Product Weight 8.8 oz (250 g)
Manufacturer Warranty 3 years

Le Hioki 8970 comprend

  • Hioki 8970 Memory HiCorder Frequency Unit, 50/60/400Hz

Poser une question sur le Hioki 8970 Memory HiCorder Frequency Unit, 50/60/400Hz

Hioki 8970 offre

Monitor the performance of commercial power lines with this Hioki 8970 Memory HiCorder Frequency Unit. The unit is built to measure motor rotation, duty ratio, pulse width, pulse integration and frequency fluctuations. The unit's isolated BNC inputs can handle up to 300 VAC/VDC from the Earth, and is compatible with select Memory HiCorder models.

Caractéristiques

  • Measures commercial power for the fluctuation of power line frequency
  • Allows direct input of class line up to 200 V
  • Delivers pulse counting for the encoder
  • Measures motor rotation, pulse integration, duty ratio and pulse width
  • Boasts 2 isolated inputs that can handle up to 300 VAC/VDC from the Earth
  • Compatible with Memory HiCorder MR6000, MR8847A, MR8827 and other models (sold separately)

Spécifications pour le Hioki 8970

Number of Channels 2
Measurement Functions Voltage input based frequency measurement, rotation, power frequency, integration, pulse duty ratio, pulse width
Input Connectors Isolated BNC
Maximum Rated Voltage to Earth 300 VAC/VDC
Power Frequency Mode Range: 50 Hz (40 to 60 Hz), 60 Hz (50 to 70 Hz), 400 Hz (390 to 410 Hz), 3 settings, Accuracy: ±0.03 Hz (exclude 400 Hz range), ±0.1 Hz (400 Hz range)
Frequency Mode Range: DC to 100 kHz (minimum pulse width 2 μs), 1 Hz/div to 5 kHz/div (full scale= 20 div), 8 settings, Accuracy: ±0.1% f.s. (exclude 5 kHz/div), ±0.7% f.s. (at 5 kHz/div)
Rotation Mode Range: 0 to 2 million rotations/minute (minimum pulse width 2 μs), 100 (r/min)/div to 100k (r/min)/div (full scale= 20 div), 7 settings, Accuracy: ±0.1% f.s. (excluding 100k (r/min)/div), ±0.7% f.s. (at 100k (r/min)/div)
Integration Mode Range Range: 2k counts/div to 1M counts/div, 6 settings, Accuracy: ±range/2000
Duty Ratio Mode Range: 10 Hz to 100 kHz (minimum pulse width 2 μs), 5%/div (full scale=20 div), Accuracy: ±1% (10 Hz to 10 kHz), ±4% (10 kHz to 100 kHz)
Pulse Width Mode Range: 2 μs to 2sec, 500 μs/div to 100 ms/dv (full scale=20 div), Accuracy: ±0.1% f.s
Other Functions Slope, level, hold, smoothing, low-pass filter, switchable DC/AC input coupling, frequency dividing, integration over-range keep/return
Input Voltage ±10 to ±400 V, 6 settings
Threshold Level Selectable
CE Compliant Yes
Product Length 7.74" (196.5 mm)
Product Width 4.17" (106 mm)
Product Height 0.78" (19.8 mm)
Product Weight 8.8 oz (250 g)
Manufacturer Warranty 3 years

Le Hioki 8970 comprend

  • Hioki 8970 Memory HiCorder Frequency Unit, 50/60/400Hz

Poser une question sur le Hioki 8970 Memory HiCorder Frequency Unit, 50/60/400Hz

Plus de produits Hioki