Attach this strain unit to your compatible Memory HiCorder to measure acceleration, load, pressure or strain waveforms. Two conversion cables are included for simple setup.
Attach this strain unit to your compatible Memory HiCorder to measure acceleration, load, pressure or strain waveforms. Two conversion cables are included for simple setup.
Discontinué!
Ce produit a été discontinué et n’est plus disponible. Il n’y a pas de produit de remplacement direct. Ne vous inquiétez pas, nous avons quelques options pour vous aider à trouver ce dont vous avez besoin:
Visitez notre catégorie Modules pour trouver des produits similaires.
Ou nous ferons une recherche et vous aiderons à trouver ce dont vous avez besoin:
With this Hioki 8960 Memory HiCorder Strain Unit, you can reliably measure acceleration, load, pressure or strain waveforms, while the 2 included conversion cables enable easy setup. The unit is capable of handling a maximum rated voltage to Earth of 33 VAC or 70 VDC.
Caractéristiques
| Number of Channels | 2 |
| Input Connectors | PRC03-12A10-7M10.5 conversion cable |
| Maximum Rated Voltage to Earth | 33 Vrms, 70 VDC |
| Suitable Transducer | Strain gauge converter, bridge impedance: 120 Ω to 1 kΩ (2 V), 350 Ω to 1 kΩ (5 V, 10 V) |
| Measurement Range | 20 to 1,000με/div, 6 ranges |
| Low-Pass Filter | 5/10/100 Hz, 1 kHz |
| Highest Sampling Rate | 200 kS/s (2-channel simultaneous sampling) |
| Frequency Characteristics | DC to 20 kHz +1/-3 dB |
| Maximum Allowable Input | 10 VDC |
| Accuracy After Auto-Balancing | DC amplitude: ±(0.4% of full scale +2 με), zero position: ±(0.1% of full scale +2 με) (at 5 Hz filter ON) |
| Anti-Aliasing Filter | Integrated filter for suppressing aliasing distortion caused by FFT processing (automatic cutoff frequency setting/OFF) |
| CE Compliant | Yes |
| Product Length | 5.85" (148.5 mm) |
| Product Width | 6.69" (170 mm) |
| Product Height | 0.79" (20 mm) |
| Product Weight | 10.2 oz (290 g) |
| Number of Channels | 2 |
| Input Connectors | PRC03-12A10-7M10.5 conversion cable |
| Maximum Rated Voltage to Earth | 33 Vrms, 70 VDC |
| Suitable Transducer | Strain gauge converter, bridge impedance: 120 Ω to 1 kΩ (2 V), 350 Ω to 1 kΩ (5 V, 10 V) |
| Measurement Range | 20 to 1,000με/div, 6 ranges |
| Low-Pass Filter | 5/10/100 Hz, 1 kHz |
| Highest Sampling Rate | 200 kS/s (2-channel simultaneous sampling) |
| Frequency Characteristics | DC to 20 kHz +1/-3 dB |
| Maximum Allowable Input | 10 VDC |
| Accuracy After Auto-Balancing | DC amplitude: ±(0.4% of full scale +2 με), zero position: ±(0.1% of full scale +2 με) (at 5 Hz filter ON) |
| Anti-Aliasing Filter | Integrated filter for suppressing aliasing distortion caused by FFT processing (automatic cutoff frequency setting/OFF) |
| CE Compliant | Yes |
| Product Length | 5.85" (148.5 mm) |
| Product Width | 6.69" (170 mm) |
| Product Height | 0.79" (20 mm) |
| Product Weight | 10.2 oz (290 g) |