Caractéristiques
| DC Voltage Range | 200 mV to 1000 V, 5 ranges Best Accuracy: ±0.010% rdg. ±2 dgt. |
| AC Voltage Range | 2000 mV to 700 V, 4 ranges Best Accuracy: ±0.1% rdg. ±100 dgt., Effective value rectifier |
| Frequency Characteristics at AC Voltage | 10 to 300 kHz |
| Resistance Range | 2-terminal measurement 200 Ω to 100 M Ω, 7 ranges Best Accuracy: ±0.02% rdg. ±2 dgt. |
| Resistance Range | 4-terminal measurement 200 Ω to 200 k Ω, 5 ranges Best Accuracy: ±0.02% rdg. ±2 dgt. |
| DC Current Range | 200 or 2000 mA, 2 ranges Best Accuracy: ±0.1% rdg. ±6 dgt. |
| AC Current Range | 200 or 2000 mA, 2 ranges Best Accuracy: ±0.3 % rdg. ±100 dgt., (or used with clamp-on sensor range) |
| Frequency Characteristics at AC Current | 10 to 30 kHz |
| Frequency Range | 100 Hz to 300 kHz, 5 ranges, |
| Accuracy | ±0.015% rdg. ±2 dgt. |
| Continuity Possible | 50 Ω or less (at 2000 Ω range) |
| Diode Check Possible | 6 V open terminal voltage |
| Other Functions | Current measurement with clamp, Comparator, external input and output, Save/Load function, AVE, trigger, RS-232C, GP-IB (-01 model) |
| Range Switching | Auto or Manual |
| Display | LED, max 199999 dgt., max 999999 dgt. at Frequency |
| Sampling Rate | Fast: 300 times/sec Medium: 8 to 9 time/sec Slow: 1 time/sec |
| Power Supply | 100 to 240 V AC, 50/60 Hz, (specify when ordering) |
| Dimensions | 8.46 x 3.15 x 10.43" (215 x 80 x 265 mm) |
| Weight | 91.7 oz (2.6 kg) |
| DC Voltage Range | 200 mV to 1000 V, 5 ranges Best Accuracy: ±0.010% rdg. ±2 dgt. |
| AC Voltage Range | 2000 mV to 700 V, 4 ranges Best Accuracy: ±0.1% rdg. ±100 dgt., Effective value rectifier |
| Frequency Characteristics at AC Voltage | 10 to 300 kHz |
| Resistance Range | 2-terminal measurement 200 Ω to 100 M Ω, 7 ranges Best Accuracy: ±0.02% rdg. ±2 dgt. |
| Resistance Range | 4-terminal measurement 200 Ω to 200 k Ω, 5 ranges Best Accuracy: ±0.02% rdg. ±2 dgt. |
| DC Current Range | 200 or 2000 mA, 2 ranges Best Accuracy: ±0.1% rdg. ±6 dgt. |
| AC Current Range | 200 or 2000 mA, 2 ranges Best Accuracy: ±0.3 % rdg. ±100 dgt., (or used with clamp-on sensor range) |
| Frequency Characteristics at AC Current | 10 to 30 kHz |
| Frequency Range | 100 Hz to 300 kHz, 5 ranges, |
| Accuracy | ±0.015% rdg. ±2 dgt. |
| Continuity Possible | 50 Ω or less (at 2000 Ω range) |
| Diode Check Possible | 6 V open terminal voltage |
| Other Functions | Current measurement with clamp, Comparator, external input and output, Save/Load function, AVE, trigger, RS-232C, GP-IB (-01 model) |
| Range Switching | Auto or Manual |
| Display | LED, max 199999 dgt., max 999999 dgt. at Frequency |
| Sampling Rate | Fast: 300 times/sec Medium: 8 to 9 time/sec Slow: 1 time/sec |
| Power Supply | 100 to 240 V AC, 50/60 Hz, (specify when ordering) |
| Dimensions | 8.46 x 3.15 x 10.43" (215 x 80 x 265 mm) |
| Weight | 91.7 oz (2.6 kg) |