The pure water tester is a rugged and reliable pocket-sized tester that offers quick and accurate readings. Features graphite electrodes to reduce polarization effects and an exposed temperature probe for fast response when compensating for temperature changes. Manual calibration is performed to a single point.

The pure water tester is a rugged and reliable pocket-sized tester that offers quick and accurate readings. Features graphite electrodes to reduce polarization effects and an exposed temperature probe for fast response when compensating for temperature changes. Manual calibration is performed to a single point.

Prix spécial $103.55 CAD
Prix régulier $109.00 CAD
Disponibilité 4 Jours
Quantité

Hanna HI98308 offre

Caractéristiques

  • Exposed temperature probe - fast response to changes in sample temperature
  • Very low range EC (0.0 to 99.9 µS/cm)
  • Single point manual calibration - calibrate with 84 µS/cm EC solution using a screwdriver
  • Automatic temperature compensation - samples automatically compensated for temperature variations (ATC)
  • Graphite electrodes - reduced polarized effects
  • Non-oxidizing graphite pins are able to provide an optimal surface for accurate, dependable results
  • Tester is housed in durable casing that provides excellent protection against harsh environments

Applications

  • Laboratory
  • Printed circuit board washing
  • Laundry
  • Steam cleaning
  • Checking car battery water
  • All areas where distilled, demineralized or pure water is used

Spécifications pour le Hanna HI98308

Conductivity
Range 0.0 to 99.9 µS/cm
Resolution 0.1 µS/cm
Accuracy ±2% F.S.
General Specifications
Calibration Manual, One Point
Temperature Compensation Automatic from 32 to 122°F (0 to 50°C) with β=2%/°C typical
Power Supply 4 x 1.5V Batteries
Battery Life Approximately 250 hours of continuous use
Environment 32 to 122°F (0 to 50°C)
RH max 95% non-condensing
Dimensions 6.9 x 1.6 x 0.9" (175 x 41 x 23 mm)

Le Hanna HI98308 comprend

  • Pure Water Tester with ATC
  • Protective Cap
  • Calibration Screwdriver
  • 4 x 1.5V Batteries
  • Instructions

Cliquer sur une catégorie pour voir une sélection d'accessoires compatible avec le Hanna HI98308 Pure Water Tester with ATC.

Hanna HI70663L Cleaning Solution for Soil Deposits, 500 mL HI70663L
Eliminate impurities and residues left on electrode surfaces when immersed in samples during measurement with this acidic cleaning solution. In addition, this solution is specially formulated for pH electrodes used in agricultural applications.




Hanna HI7033M Conductivity Standard, 84 µS/cm, 230 mL HI7033M
Calibration solution that is prepared against a NIST traceable potassium chloride solution.




Poser une question sur le Hanna HI98308 Pure Water Tester with ATC

Hanna HI98308 offre

Caractéristiques

  • Exposed temperature probe - fast response to changes in sample temperature
  • Very low range EC (0.0 to 99.9 µS/cm)
  • Single point manual calibration - calibrate with 84 µS/cm EC solution using a screwdriver
  • Automatic temperature compensation - samples automatically compensated for temperature variations (ATC)
  • Graphite electrodes - reduced polarized effects
  • Non-oxidizing graphite pins are able to provide an optimal surface for accurate, dependable results
  • Tester is housed in durable casing that provides excellent protection against harsh environments

Applications

  • Laboratory
  • Printed circuit board washing
  • Laundry
  • Steam cleaning
  • Checking car battery water
  • All areas where distilled, demineralized or pure water is used

Spécifications pour le Hanna HI98308

Conductivity
Range 0.0 to 99.9 µS/cm
Resolution 0.1 µS/cm
Accuracy ±2% F.S.
General Specifications
Calibration Manual, One Point
Temperature Compensation Automatic from 32 to 122°F (0 to 50°C) with β=2%/°C typical
Power Supply 4 x 1.5V Batteries
Battery Life Approximately 250 hours of continuous use
Environment 32 to 122°F (0 to 50°C)
RH max 95% non-condensing
Dimensions 6.9 x 1.6 x 0.9" (175 x 41 x 23 mm)

Le Hanna HI98308 comprend

  • Pure Water Tester with ATC
  • Protective Cap
  • Calibration Screwdriver
  • 4 x 1.5V Batteries
  • Instructions

Cliquer sur une catégorie pour voir une sélection d'accessoires compatible avec le Hanna HI98308 Pure Water Tester with ATC.

Hanna HI70663L Cleaning Solution for Soil Deposits, 500 mL HI70663L
Eliminate impurities and residues left on electrode surfaces when immersed in samples during measurement with this acidic cleaning solution. In addition, this solution is specially formulated for pH electrodes used in agricultural applications.




Hanna HI7033M Conductivity Standard, 84 µS/cm, 230 mL HI7033M
Calibration solution that is prepared against a NIST traceable potassium chloride solution.