Hanna HI93510N Waterproof Thermistor Thermometer

Modèle: HI93510N | No. de commande: HI 93510N

Hanna HI93510N Waterproof Thermistor Thermometer

Modèle: HI93510N | No. de commande: HI 93510N

Ideal for indoor and outdoor use, this waterproof thermistor thermometer features high accuracy and rugged construction. Reliable and versatile, the thermometer offers features such as a selection of celsius or Fahrenheit units, hold function, low and high reading display, and a battery error prevention system.

Ideal for indoor and outdoor use, this waterproof thermistor thermometer features high accuracy and rugged construction. Reliable and versatile, the thermometer offers features such as a selection of celsius or Fahrenheit units, hold function, low and high reading display, and a battery error prevention system.

Discontinué!

Ce produit a été discontinué et n’est plus disponible.

Il n’y a pas de remplacement direct, mais nous vous recommandons:

Hanna HI935005 K-Type Thermocouple Thermometer with auto-off capability, -58 to 399.9°F and 400 to 2462°F, °C/°F readout-

Hanna HI935005 K-Type Thermocouple Thermometer with auto-off capability, -58 to 399.9°F and 400 to 2462°F, °C/°F readout

Modèle: HI935005 | No. de commande: HI 935005

Get high accuracy temperature measurements with this waterproof thermocouple thermometer which offers two measurement ranges. In addition, this thermometer can be used with a wide variety of K-type probes and is suited for temperature measurements in the laboratory or field.


HANNA HI 766E1 Probe, General Purpose, K-Type, 1m Cable-

HANNA HI 766E1 Probe, General Purpose, K-Type, 1m Cable

Modèle: HI 766E1

General Purpose Probe with integral handle and 1 m (3.3') cable; length of 12 cm.


Vous ne trouvez pas ce que vous cherchez? Nous ferons une recherche et vous aiderons à trouver ce dont vous avez besoin.


Hanna HI93510N Offers

Constructed from stainless steel, this probe measures samples up to 150°C (302°F).

Features

  • °C/°F readout: measurements can be displayed in either degrees Celsius or Fahrenheit
  • A simple press of the °C/°F button will switch between the two scales
  • Interchangeable thermistor probes: a wide range of thermistor type probes are available to meet the specific needs of users
  • High/Low function: the maximum and minimum temperature values are continuously displayed along with current reading on the LCD display
  • HOLD function: freezes the display to allow the user time to record readings, the meter continues to internally monitor the temperature and update the high and low measurement values
  • Automatic shut-off: the meter can be set to turn off after 8 minutes, 60 minutes, or disabled
  • Battery Error Prevention System (BEPS): will shut the meter off when the battery power is too low for an accurate measurement
  • Low battery indicator: when level is below 10%, a warning symbol will blink to indicate low battery condition.

Applications

  • Laboratory
  • Indoor
  • Outdoor

Hanna HI93510N Specifications

Range -58 to 302°F (-50 to 150°C)
Resolution 0.1°F ( 0.1°C ); -58 to 230°F; 0.2°F (outside)
Accuracy at 68°F/20°C) ±0.4°C / ±0.8°F for one year, excluding probe error
Typical EMC Deviation Probe ±1°F (±0.5°C) with probe
Auto-Off User selectable: 8 min, 60 min, disabled
Environment 14 to 122°F (-10 to 50°C); RH 100%
Battery 3 x 1.5V AA (IEC LR6) batteries
Approx. 2000 hours of continuous use (BL off)
Dimensions 5.9 x 3.1 x 1.4" (150 x 80 x 36 mm)
Weight 8.3 oz. (235 g)

Le Hanna HI93510N comprend

  • Hanna HI93510N Waterproof Thermistor Thermometer

Poser une question sur le Hanna HI93510N Waterproof Thermistor Thermometer

Hanna HI93510N Offers

Constructed from stainless steel, this probe measures samples up to 150°C (302°F).

Features

  • °C/°F readout: measurements can be displayed in either degrees Celsius or Fahrenheit
  • A simple press of the °C/°F button will switch between the two scales
  • Interchangeable thermistor probes: a wide range of thermistor type probes are available to meet the specific needs of users
  • High/Low function: the maximum and minimum temperature values are continuously displayed along with current reading on the LCD display
  • HOLD function: freezes the display to allow the user time to record readings, the meter continues to internally monitor the temperature and update the high and low measurement values
  • Automatic shut-off: the meter can be set to turn off after 8 minutes, 60 minutes, or disabled
  • Battery Error Prevention System (BEPS): will shut the meter off when the battery power is too low for an accurate measurement
  • Low battery indicator: when level is below 10%, a warning symbol will blink to indicate low battery condition.

Applications

  • Laboratory
  • Indoor
  • Outdoor

Hanna HI93510N Specifications

Range -58 to 302°F (-50 to 150°C)
Resolution 0.1°F ( 0.1°C ); -58 to 230°F; 0.2°F (outside)
Accuracy at 68°F/20°C) ±0.4°C / ±0.8°F for one year, excluding probe error
Typical EMC Deviation Probe ±1°F (±0.5°C) with probe
Auto-Off User selectable: 8 min, 60 min, disabled
Environment 14 to 122°F (-10 to 50°C); RH 100%
Battery 3 x 1.5V AA (IEC LR6) batteries
Approx. 2000 hours of continuous use (BL off)
Dimensions 5.9 x 3.1 x 1.4" (150 x 80 x 36 mm)
Weight 8.3 oz. (235 g)

Le Hanna HI93510N comprend

  • Hanna HI93510N Waterproof Thermistor Thermometer

Poser une question sur le Hanna HI93510N Waterproof Thermistor Thermometer

Plus de produits Hanna