Hanna HI3133B Platinum ORP Half-Cell Electrode with BNC connector

Modèle: HI3133B | No. de commande: HI 3133B

Hanna HI3133B Platinum ORP Half-Cell Electrode with BNC connector

Modèle: HI3133B | No. de commande: HI 3133B

Versatile and reliable, this half-cell electrode with a BNC connector features a platinum pin and glass body. Compatible with a reference half-cell electrode, the half-cell electrode comes with a glass body that is ideal for laboratory use and ORP titrations.

Versatile and reliable, this half-cell electrode with a BNC connector features a platinum pin and glass body. Compatible with a reference half-cell electrode, the half-cell electrode comes with a glass body that is ideal for laboratory use and ORP titrations.

Prix spécial $271.70 CAD
Prix régulier $286.00 CAD
Disponibilité 2 Jours
Quantité

Hanna HI3133B Offers

With a body made of glass, this half-cell electrode is made with a platinum pin.

Features

  • Half-Cell Design
  • BNC Connection
  • Platinum Pin

Applications

  • ORP titrations

Platinum Sensing Pin

The ORP sensor is made with platinum. An ORP sensor must be chemically inert; it cannot be oxidized or reduced itself. It must also have the proper surface characteristics to promote rapid electron exchange, a property known as high exchange current density. Two noble metals have proven to work well for this purpose: pure platinum and pure gold are both used in the construction of ORP sensors. The platinum sensor is often preferred because it is mechanically simpler and safer to produce. Platinum can be welded to glass and has the same thermal coefficient. The platinum sensor signal is carried through the electrode body, and together with the reference signal is conducted to the measurement meter.

Glass Body

The glass body is ideal for laboratory use. The glass is resistant to many harsh chemicals and is easily cleaned. The glass body also allows for a fast transfer of heat to the internal reference electrolyte. The mV generated by the reference cell is temperature-dependent. The faster the equilibrium the steadier the reference potential.

the electrode body, and together with the reference signal is conducted to the measurement meter.

BNC Connector

The electrode uses a BNC connector. This type of connector is universal in that it can be used on any pH meter that has the female BNC probe input. Other type of connectors include DIN, screw type, T-type, and 3.5mm to name a few. These types of connectors tend to be proprietary for a particular type of meter and are not interchangeable.

Hanna HI3133B Specifications

Description ORP half-cell
Half Cell Platinum
Range mV
Recommended Operating Temperature 23 to 212°F (-5 to 100°C)
Tip / Shape Platinum pin
Cable Coaxial
Recommended Use General purpose, potentiometric titration
Connection BNC
Body Material Glass

Le Hanna HI3133B comprend

  • Hanna HI3133B Platinum ORP Half-Cell Electrode with BNC connector

Poser une question sur le Hanna HI3133B Platinum ORP Half-Cell Electrode with BNC connector

Hanna HI3133B Offers

With a body made of glass, this half-cell electrode is made with a platinum pin.

Features

  • Half-Cell Design
  • BNC Connection
  • Platinum Pin

Applications

  • ORP titrations

Platinum Sensing Pin

The ORP sensor is made with platinum. An ORP sensor must be chemically inert; it cannot be oxidized or reduced itself. It must also have the proper surface characteristics to promote rapid electron exchange, a property known as high exchange current density. Two noble metals have proven to work well for this purpose: pure platinum and pure gold are both used in the construction of ORP sensors. The platinum sensor is often preferred because it is mechanically simpler and safer to produce. Platinum can be welded to glass and has the same thermal coefficient. The platinum sensor signal is carried through the electrode body, and together with the reference signal is conducted to the measurement meter.

Glass Body

The glass body is ideal for laboratory use. The glass is resistant to many harsh chemicals and is easily cleaned. The glass body also allows for a fast transfer of heat to the internal reference electrolyte. The mV generated by the reference cell is temperature-dependent. The faster the equilibrium the steadier the reference potential.

the electrode body, and together with the reference signal is conducted to the measurement meter.

BNC Connector

The electrode uses a BNC connector. This type of connector is universal in that it can be used on any pH meter that has the female BNC probe input. Other type of connectors include DIN, screw type, T-type, and 3.5mm to name a few. These types of connectors tend to be proprietary for a particular type of meter and are not interchangeable.

Hanna HI3133B Specifications

Description ORP half-cell
Half Cell Platinum
Range mV
Recommended Operating Temperature 23 to 212°F (-5 to 100°C)
Tip / Shape Platinum pin
Cable Coaxial
Recommended Use General purpose, potentiometric titration
Connection BNC
Body Material Glass

Le Hanna HI3133B comprend

  • Hanna HI3133B Platinum ORP Half-Cell Electrode with BNC connector

Poser une question sur le Hanna HI3133B Platinum ORP Half-Cell Electrode with BNC connector

Plus de produits Hanna