Hanna HI2002 edge Dedicated pH/ORP Meter

Modèle: HI2002 | No. de commande: HI 2002-01

Hanna HI2002 edge Dedicated pH/ORP Meter

Modèle: HI2002 | No. de commande: HI 2002-01

The innovative meter edge® design offers an easy to use meter that can measure pH and ORP. Incredibly versatile, and can be used in a variety of environments without taking up the space of a traditional benchtop meter.

The innovative meter edge® design offers an easy to use meter that can measure pH and ORP. Incredibly versatile, and can be used in a variety of environments without taking up the space of a traditional benchtop meter.

Prix spécial $560.50 CAD
Prix régulier $590.00 CAD
Disponibilité 4 Jours
Quantité

Hanna HI2002 Offers

The body of the meter is about half the size of a mini-tablet and is only 0.5" thick. The keypad being part of a screen allows for accidental benchtop spills to be wiped right off the screen. Not only is t portable, but it also has an internal memory that can store up to 1,000 readings.

Features

  • Advanced pH electrode diagnostics
  • Easy clean touch keypad
  • Capacitive Touch
  • Large, easy to read LCD
  • Digital pH electrodes
  • CAL Check
  • Sensor check
  • Wall mount
  • 3.5mm probe input
  • Cradle and electrode holder
  • Two USB Ports
  • Data logging
  • Two operating modes

Benchtop

It can sit on a benchtop stand with a spring-loaded probe holder, great for any kind of lab and benchtop pH applications.

Wall Mount

Can be used in a handy wall-mounted cradle, a good space saving alternative! The cradle also serves as a battery charger.

Portable

Fully portable; it can be taken out of the cradle and run on battery power as a handheld meter.

Wine-Specific Probe

  • Clog Prevention Sleeve (CPS)
  • Embedded microchip stores profile
  • Specific glass bulb for fast response

It features a special Clogging Prevention System (CPS) that prevents suspended solids from blocking the junction (the channel for electrolyte to flow). This probe has a built in temperature sensor, allowing the meter to adjust your pH readings to standard conditions.

In the winery, this can make a difference when you are reading your wine pH values at or just after fermentation (when they are likely to be warmer) versus in the middle of the winter, when wines in barrels or tanks might be at around 55°F.

This probe, like all probes for edge®, has a built-in microchip that stores sensor type, serial number, and calibration information. What this does for you is it allows the meter to instantly recognize which probe it is connected and when calibration needs to be performed.

Are you Making Errors when Measuring pH?

  • Storing the electrode dry
  • Wiping the sensing glass
  • Storing the electrode in DI water
  • Not cleaning the electrode
  • Calibration errors
  • Electrode selection
  • Not loosening or removing the fill hole cap
  • Electrolyte fill level
  • Inadequate probe submersion
  • Using an old or expired electrode

Hanna HI2002 Specifications

pH
Range Standard Mode: -2.000 to 16.000 pH
Basic Mode: -2.00 to 16.00 pH
Resolution 0.001 pH, 0.01 pH
Accuracy (@25°C/77°F) ±0.01 pH, ±0.002 pH
Calibration 5 points (Standard mode) 1.68, 4.01 (3.00†), 6.86, 7.01, 9.18, 10.01, 12.45, and two custom buffers; 3 points (Basic mode) 4.01; 6.86; 7.01; 9.18; 10.01
Temperature Compensation ATC: -5.0 to 100.0°C; 23.0 to 212.0°F
mV
Range ±1000.0 mV; ±2000.0 mV
Resolution 0.1 mV
Accuracy ±0.2 mV (±999.9 mV); ±1 mV (±2000 mV)
Cliquer ici pour toutes les spécifications du Hanna HI2002

What's included with the Hanna HI2002

  • Dedicated pH/ORP Meter
  • Benchtop Docking Station with Electrode Holder
  • Wall Mount Cradle
  • USB Cable
  • Glass Body
  • Refillable pH Electrode with Temperature Sensor
  • 2 x Sachets each of pH 4, 7, 10, Cleaning Solution
  • 5 VDC Power Adapter
  • Instruction Manual

Cliquer sur une catégorie pour voir une sélection d'accessoires compatible avec le Hanna HI2002 edge Dedicated pH/ORP Meter.

Hanna Instruments HI7004L Solution tampon pH 4.01, flacon de 500 mL HI7004L
Les solutions tampons Hanna sont préparées selon des formules précises et sont standardisées à l'aide d'un pH-mètre calibré selon les normes NIST. Les sachets de 20 ml sont des monodoses, tandis que pour les applications plus exigeantes, vous pouvez choisir entre des emballages de 230 ml, 500 ml, 1 litre ou 1 gallon (3.78 L). Toutes les solutions pH 4 portent le numéro de lot, la date de péremption et le tableau de corrélation entre le pH et la température. Cette valeur tampon est largement utilisée dans les stations d'épuration des eaux, dans l'industrie alimentaire et partout où le pH doit être légèrement acide.




Hanna HI7082L Electrolyte Solution 3.5M KCI, 460 mL HI7082L
Electrolyte solution to ensure the correct electrode performance.




Hanna HI70300L Solution de stockage d'électrode, 500 mL HI70300L
Une solution de stockage préparée avec des produits chimiques de qualité réactif qui peut être utilisée pour assurer une performance optimale de vos électrodes pH et ORP. Il est nécessaire de stocker une électrode de pH dans une solution afin de maintenir la membrane de verre de l'électrode de pH hydratée.




Hanna HI7010L Solution d'étalonnage pH, 10.01, 500 ml HI7010L
Solution tampon d'étalonnage avec un pH de 10.01. Le numéro de lot et la date de péremption sont clairement indiqués sur l'étiquette, avec une fermeture hermétique et inviolable, afin de garantir la qualité de la solution. La gamme de tampons d'étalonnage Hanna a été spécialement formulée pour avoir une expiration de 2 ans à partir de la date de fabrication pour une bouteille non ouverte.




Hanna HI7061L Solution de nettoyage usage général, 500 mL HI7061L
Les électrodes peuvent se salir à l'usage et produire des résultats inexacts même si elles sont correctement lues dans un tampon pH. Il s'agit d'une solution de nettoyage générale qui peut être utilisée pour une variété d'applications.




Hanna HI7007L Solution d'étalonnage, pH 7.01, 500 mL HI7007L
Solution tampon d'étalonnage avec un pH de 7.01. Le numéro de lot et la date de péremption sont clairement indiqués sur l'étiquette, avec une fermeture hermétique et inviolable, afin de garantir la qualité de la solution. La gamme de tampons d'étalonnage Hanna a été spécialement formulée pour avoir une expiration de 2 ans à partir de la date de fabrication pour une bouteille non ouverte.




Hanna HI7082M Electrolyte Solution 3.5M KCl, 230 mL HI7082M
This is a pH and ORP electrode fill solution that contains 3.5M KCl, which is specifically produced for double junction electrodes.




Hanna HI12300 Digital PEI Body pH Electrode for Field Applications HI12300
Plastic body, double junction, gel filled pH electrode, with a built-in temperature sensor for temperature compensated measurements in a single probe design.




Hanna HI10480 Digital Glass Body pH Electrode with Clogging Prevention System HI10480
Digital pH electrode with a built-in temperature sensor, specifically designed for measuring the pH in wine.




Poser une question sur le Hanna HI2002 edge Dedicated pH/ORP Meter

Hanna HI2002 Offers

The body of the meter is about half the size of a mini-tablet and is only 0.5" thick. The keypad being part of a screen allows for accidental benchtop spills to be wiped right off the screen. Not only is t portable, but it also has an internal memory that can store up to 1,000 readings.

Features

  • Advanced pH electrode diagnostics
  • Easy clean touch keypad
  • Capacitive Touch
  • Large, easy to read LCD
  • Digital pH electrodes
  • CAL Check
  • Sensor check
  • Wall mount
  • 3.5mm probe input
  • Cradle and electrode holder
  • Two USB Ports
  • Data logging
  • Two operating modes

Benchtop

It can sit on a benchtop stand with a spring-loaded probe holder, great for any kind of lab and benchtop pH applications.

Wall Mount

Can be used in a handy wall-mounted cradle, a good space saving alternative! The cradle also serves as a battery charger.

Portable

Fully portable; it can be taken out of the cradle and run on battery power as a handheld meter.

Wine-Specific Probe

  • Clog Prevention Sleeve (CPS)
  • Embedded microchip stores profile
  • Specific glass bulb for fast response

It features a special Clogging Prevention System (CPS) that prevents suspended solids from blocking the junction (the channel for electrolyte to flow). This probe has a built in temperature sensor, allowing the meter to adjust your pH readings to standard conditions.

In the winery, this can make a difference when you are reading your wine pH values at or just after fermentation (when they are likely to be warmer) versus in the middle of the winter, when wines in barrels or tanks might be at around 55°F.

This probe, like all probes for edge®, has a built-in microchip that stores sensor type, serial number, and calibration information. What this does for you is it allows the meter to instantly recognize which probe it is connected and when calibration needs to be performed.

Are you Making Errors when Measuring pH?

  • Storing the electrode dry
  • Wiping the sensing glass
  • Storing the electrode in DI water
  • Not cleaning the electrode
  • Calibration errors
  • Electrode selection
  • Not loosening or removing the fill hole cap
  • Electrolyte fill level
  • Inadequate probe submersion
  • Using an old or expired electrode

Hanna HI2002 Specifications

pH
Range Standard Mode: -2.000 to 16.000 pH
Basic Mode: -2.00 to 16.00 pH
Resolution 0.001 pH, 0.01 pH
Accuracy (@25°C/77°F) ±0.01 pH, ±0.002 pH
Calibration 5 points (Standard mode) 1.68, 4.01 (3.00†), 6.86, 7.01, 9.18, 10.01, 12.45, and two custom buffers; 3 points (Basic mode) 4.01; 6.86; 7.01; 9.18; 10.01
Temperature Compensation ATC: -5.0 to 100.0°C; 23.0 to 212.0°F
mV
Range ±1000.0 mV; ±2000.0 mV
Resolution 0.1 mV
Accuracy ±0.2 mV (±999.9 mV); ±1 mV (±2000 mV)
Cliquer ici pour toutes les spécifications du Hanna HI2002

What's included with the Hanna HI2002

  • Dedicated pH/ORP Meter
  • Benchtop Docking Station with Electrode Holder
  • Wall Mount Cradle
  • USB Cable
  • Glass Body
  • Refillable pH Electrode with Temperature Sensor
  • 2 x Sachets each of pH 4, 7, 10, Cleaning Solution
  • 5 VDC Power Adapter
  • Instruction Manual

Cliquer sur une catégorie pour voir une sélection d'accessoires compatible avec le Hanna HI2002 edge Dedicated pH/ORP Meter.

Hanna Instruments HI7004L Solution tampon pH 4.01, flacon de 500 mL HI7004L
Les solutions tampons Hanna sont préparées selon des formules précises et sont standardisées à l'aide d'un pH-mètre calibré selon les normes NIST. Les sachets de 20 ml sont des monodoses, tandis que pour les applications plus exigeantes, vous pouvez choisir entre des emballages de 230 ml, 500 ml, 1 litre ou 1 gallon (3.78 L). Toutes les solutions pH 4 portent le numéro de lot, la date de péremption et le tableau de corrélation entre le pH et la température. Cette valeur tampon est largement utilisée dans les stations d'épuration des eaux, dans l'industrie alimentaire et partout où le pH doit être légèrement acide.




Hanna HI7082L Electrolyte Solution 3.5M KCI, 460 mL HI7082L
Electrolyte solution to ensure the correct electrode performance.




Hanna HI70300L Solution de stockage d'électrode, 500 mL HI70300L
Une solution de stockage préparée avec des produits chimiques de qualité réactif qui peut être utilisée pour assurer une performance optimale de vos électrodes pH et ORP. Il est nécessaire de stocker une électrode de pH dans une solution afin de maintenir la membrane de verre de l'électrode de pH hydratée.




Hanna HI7010L Solution d'étalonnage pH, 10.01, 500 ml HI7010L
Solution tampon d'étalonnage avec un pH de 10.01. Le numéro de lot et la date de péremption sont clairement indiqués sur l'étiquette, avec une fermeture hermétique et inviolable, afin de garantir la qualité de la solution. La gamme de tampons d'étalonnage Hanna a été spécialement formulée pour avoir une expiration de 2 ans à partir de la date de fabrication pour une bouteille non ouverte.




Hanna HI7061L Solution de nettoyage usage général, 500 mL HI7061L
Les électrodes peuvent se salir à l'usage et produire des résultats inexacts même si elles sont correctement lues dans un tampon pH. Il s'agit d'une solution de nettoyage générale qui peut être utilisée pour une variété d'applications.




Hanna HI7007L Solution d'étalonnage, pH 7.01, 500 mL HI7007L
Solution tampon d'étalonnage avec un pH de 7.01. Le numéro de lot et la date de péremption sont clairement indiqués sur l'étiquette, avec une fermeture hermétique et inviolable, afin de garantir la qualité de la solution. La gamme de tampons d'étalonnage Hanna a été spécialement formulée pour avoir une expiration de 2 ans à partir de la date de fabrication pour une bouteille non ouverte.




Hanna HI7082M Electrolyte Solution 3.5M KCl, 230 mL HI7082M
This is a pH and ORP electrode fill solution that contains 3.5M KCl, which is specifically produced for double junction electrodes.




Hanna HI12300 Digital PEI Body pH Electrode for Field Applications HI12300
Plastic body, double junction, gel filled pH electrode, with a built-in temperature sensor for temperature compensated measurements in a single probe design.




Hanna HI10480 Digital Glass Body pH Electrode with Clogging Prevention System HI10480
Digital pH electrode with a built-in temperature sensor, specifically designed for measuring the pH in wine.




Poser une question sur le Hanna HI2002 edge Dedicated pH/ORP Meter

Plus de produits Hanna