Gel-filled and made from titanium, this single reference junction pH electrode features a built-in temperature sensor and a quick connect DIN connector. With an extendable cloth type junction, this electrode is ideal for measuring the pH in industrial, municipal, and environmental applications.

Gel-filled and made from titanium, this single reference junction pH electrode features a built-in temperature sensor and a quick connect DIN connector. With an extendable cloth type junction, this electrode is ideal for measuring the pH in industrial, municipal, and environmental applications.

Prix spécial $285.95 CAD
Prix régulier $301.00 CAD
Disponibilité 1 en inventaire
Quantité

Hanna HI12963 Offers

To use with samples that are between 32 to 176°F (0 to 80°C), the pH electrode features a cloth junction with gel electrolyte.

Spherical Bulb

The spherical bulb is for general purpose use. Other tip shapes include conic for penetration and flat tip for surface measurements.

Titanium Body

A titanium body increases immunity to electrostatic and magnetic fields. It also allows for strong corrosion resistance, even in seawater.

Cloth Junction

This type of junction is often used on electrodes with gelled electrolytes. The advantage of this junction is it is renewable; as the cloth-like material is pulled out from its position, the junction is renewed with an uncontaminated, fresh surface.

Quick Connect DIN Connector

The HI12963 uses a Quick Connect DIN connector that makes attaching and removing the probe simple and easy. This type of connector is proprietary to the meter. See specifications table for compatible meters.

Hanna HI12963 Specifications

Reference single, Ag/AgCl
Junction / Flow Rate Cloth
Electrolyte Gel
Max Pressure 3 bar
Range pH: 0 to 13
Recommended Operating Temperature 32 to 176°F (0 to 80°C) - GP
Tip / Shape Spheric (diameter: 5 mm)
Temperature Sensor Yes
Amplifier Yes
Body Material Titanium
Cable 7-pole; 3.3’ (1 m)
Recommended Use Wastewater
Connection Quick Connect DIN

Le Hanna HI12963 comprend

  • Hanna HI12963 Titanium Body pH Electrode with Quick-Connect DIN connector

Poser une question sur le Hanna HI12963 Titanium Body pH Electrode with Quick-Connect DIN connector

Hanna HI12963 Offers

To use with samples that are between 32 to 176°F (0 to 80°C), the pH electrode features a cloth junction with gel electrolyte.

Spherical Bulb

The spherical bulb is for general purpose use. Other tip shapes include conic for penetration and flat tip for surface measurements.

Titanium Body

A titanium body increases immunity to electrostatic and magnetic fields. It also allows for strong corrosion resistance, even in seawater.

Cloth Junction

This type of junction is often used on electrodes with gelled electrolytes. The advantage of this junction is it is renewable; as the cloth-like material is pulled out from its position, the junction is renewed with an uncontaminated, fresh surface.

Quick Connect DIN Connector

The HI12963 uses a Quick Connect DIN connector that makes attaching and removing the probe simple and easy. This type of connector is proprietary to the meter. See specifications table for compatible meters.

Hanna HI12963 Specifications

Reference single, Ag/AgCl
Junction / Flow Rate Cloth
Electrolyte Gel
Max Pressure 3 bar
Range pH: 0 to 13
Recommended Operating Temperature 32 to 176°F (0 to 80°C) - GP
Tip / Shape Spheric (diameter: 5 mm)
Temperature Sensor Yes
Amplifier Yes
Body Material Titanium
Cable 7-pole; 3.3’ (1 m)
Recommended Use Wastewater
Connection Quick Connect DIN