Hanna HI 7042S Dissolved Oxygen Electrolyte Solution, 1.01 oz

Modèle: HI7042S | No. de commande: HI 7042S

Hanna HI 7042S Dissolved Oxygen Electrolyte Solution, 1.01 oz

Modèle: HI7042S | No. de commande: HI 7042S

Suitable for galvanic dissolved oxygen probes, this dissolved oxygen electrolyte solution ensures the proper performance of your dissolved oxygen probes.

Suitable for galvanic dissolved oxygen probes, this dissolved oxygen electrolyte solution ensures the proper performance of your dissolved oxygen probes.

Prix spécial $27.55 CAD
Prix régulier $29.00 CAD
Disponibilité 4 Jours
Quantité

Hanna HI7042S Offers

Features

  • Convenient dropper bottle
  • Made with reagent grade chemicals

How to use

Designed to refill the electrolyte solution for galvanic dissolved oxygen probes. Galvanic sensor technology requires no external voltage since the difference in potential between the cathode and anode is greater than 0.5 volts. Galvanic DO sensors consist of two electrodes, a zinc anode and silver cathode, both of which are immersed in electrolyte solution. An oxygen permeable membrane separates the anode and cathode from the water being measured. Oxygen diffuses across the membrane and interacts with the probe internals to produce an electrical current that is proportional to the concentration of oxygen in a solution.

Hanna HI7042S Specifications

Size 1.01 oz (30 mL)

Le Hanna HI7042S comprend

  • Hanna HI 7042S Dissolved Oxygen Electrolyte Solution, 1.01 oz

Poser une question sur le Hanna HI 7042S Dissolved Oxygen Electrolyte Solution, 1.01 oz

Hanna HI7042S Offers

Features

  • Convenient dropper bottle
  • Made with reagent grade chemicals

How to use

Designed to refill the electrolyte solution for galvanic dissolved oxygen probes. Galvanic sensor technology requires no external voltage since the difference in potential between the cathode and anode is greater than 0.5 volts. Galvanic DO sensors consist of two electrodes, a zinc anode and silver cathode, both of which are immersed in electrolyte solution. An oxygen permeable membrane separates the anode and cathode from the water being measured. Oxygen diffuses across the membrane and interacts with the probe internals to produce an electrical current that is proportional to the concentration of oxygen in a solution.

Hanna HI7042S Specifications

Size 1.01 oz (30 mL)

Le Hanna HI7042S comprend

  • Hanna HI 7042S Dissolved Oxygen Electrolyte Solution, 1.01 oz