For use with logic amp, the floating voltage input probe is used as an accessory.
For use with logic amp, the floating voltage input probe is used as an accessory.
Application | Checking relay coil voltage or the operational timing of voltage ON/OFF from the control panel unit |
No. of Inputs | 4 channels (floating for each channel) |
Input Range | High, Low |
Input Resistance | High: approx. 100 kΩ Low: approx. 50 kΩ |
Detectable Voltages | High: 100 to 250 VAC, 80 to 250 VDC Low: 50 to 150 VAC, 20 to 150 VDC |
Non-Detectable Voltages | High: 0 to 20 VAC, 0 to 29 VDC Low: 0 to 10 VAC, 0 to 15 VDC |
Response Times | High: within 1 ms, Low: within 3 ms |
Maximum Floating Voltage | 250 VDC, ACp-p |