Gossen Metrawatt METRAHIT IM XTRA BT Multimeter with bluetooth, 50 to 1000 V, 0 to 3.1 gΩ

Modèle: METRAHIT IM XTRA BT | No. de commande: M274I

Gossen Metrawatt METRAHIT IM XTRA BT Multimeter with bluetooth, 50 to 1000 V, 0 to 3.1 gΩ

Modèle: METRAHIT IM XTRA BT | No. de commande: M274I

Work with this all-in-one Bluetooth multimeter with insulation resistance up to 3.1gΩ and test voltages ranging from 50 to 1000 V. Use this multimeter as an isolation tester, milliohm meter, TRMS multimeter, and a short-circuited coil tester.

Work with this all-in-one Bluetooth multimeter with insulation resistance up to 3.1gΩ and test voltages ranging from 50 to 1000 V. Use this multimeter as an isolation tester, milliohm meter, TRMS multimeter, and a short-circuited coil tester.

Prix spécial $4289.74 CAD
Prix régulier $4714.00 CAD
Disponibilité 2 à 3 semaines
Quantité

Gossen Metrawatt METRAHIT IM XTRA BT offre

Portable and rugged, take multiple measurements with this multimeter well suited for applications such as service and diagnostics at electric machines, maintenance, automotive, safety testing, and more.

Caractéristiques

  • An all-in-one high resoltuion instrument with 30,000 digits: milliohmmeter, multimeter, data logger, insulation resistance tester and coil tester
  • Compact and multifunctional
  • Safety-relevant tests for electric devices, drives and installations with a single field instrument
  • Testing of high-voltage systems in accordance with UN ECE R100
  • Insulation resistance measurement per EN 61557-2 / VDE 0413-2
  • Rlow installation testing per EN 61557-4 / VDE 0413-4
  • Bonding test and equipotential bonding measurement, e.g. on aircraft outer skins (lightning protection, wick test)
  • Insulation resistance measurement up to 3.1 GΩ with interference voltage detection, test voltages: 50, 100, 250, 500 and 1000 V per EN 61557-2
  • DAR: dielectric absorption rate, PI: polarization index
  • Short-circuited coil test with 1000 V
  • Multifunctional measuring instrument (V, A, Ω, F, Hz, °F/°C, %)
  • TRMS AC / AC+DC measurement for current/voltage value up to 10/100 kHz
  • Capacitance measurement
  • Precision temperature measurement °F, and °C for RTD and TC-K sensors
  • Data logger thanks to integrated memory module and real-time clock, individual measurements as well
  • Programmable sequences for test routines
  • Color graphic display
  • Modular power supply: standard quick-change rechargeable lithium battery, change without interrupting the measuring circuit thanks to touch protected module socket
  • Automatic blocking sockets for the current input
  • Test probe with START (ISO) and STORE keys
  • Housing with IP52 protection, dust protected and drip-proof, replaceable rubber holster
  • Interfaces: Bluetooth
  • IZYTRONIQ windows software for documentation, preparation of test reports
  • Display resolution: high resolution with 30,000 digits and a basic accuracy of 0.15%

Insulation resistance measurement with interference voltage detection

Insulation resistance measurement with test voltages of 50 to 1000 V. If interference voltage of greater than 15 V AC or 25 V DC is detected during insulation measurement, the device issues an optical and acoustic warning whereupon measurements cannot be launched. Afterward, automatic switching to TRMSAC+DC voltage measurement at 1 MΩ takes place and the currently measured voltage is displayed as Uext.

Polarization index (PI)

When test voltage is applied, insulation resistance is measured after one minute and after ten minutes. The polarization index is the ratio that results from the two measured values. In the case of electric drive units, a value of at least two indicates intact insulation and a value of greater than 4 indicates very good insulation.

Absorption index (DAR)

Practically speaking, the absorption index test is a quick polarization index measurement. The ISO values measured after 30 and 60 seconds are used to generate a ratio.

Kelvin connection for 4-Wire measurement (4-L) (milliohm measurement)

The 4-wire measurement compensates for influences resulting from cable and contact resistances which must not be neglected when measuring very small resistances. Measuring current can be set to 200 mA or 1 A. In this way, even extremely small contact resistances can be measured, for example at welded and riveted joints and on aircraft outer skins (lightning protection and wick test), or equipotential bonding is measured in accordance with UN ECE R100 in hybrid and electric vehicles.

2-Wire Rlo measurement with 200 mA test current per EN 61557

Low-resistance measurement per EN 61557-4 for earth, protective and equipotential bonding conductors. If excessive interference current is detected during insulation measurement, the device issues an optical and acoustic warning whereupon measurements cannot be launched.

RMS value with distorted waveforms

The utilized measuring method allows for waveform-independent TRMS measurement of alternating quantities (AC) and pulsating quantities (AC and DC) for voltage and current at up to 100 kHz.

Activatable filter for V AC measurement

A 1 kHz low-pass filter can be activated if required, for example when measuring cables with parasitic external signals. The input signal is checked by a voltage comparator for dangerous voltages as long as the low-pass filter is activated, and these are indicated at the display if applicable.

Diode testing with constant current Ik = 1 mA

Testing of the polarity of diodes and checking for short-circuits and interruptions in electrical circuits. The test voltage source makes it possible to measure LEDs and reference diodes up to 4.5 V, e.g. also white LEDs.

Fast Acoustic Continuity Test Ik = 1 mA

Testing for short-circuiting or interruption in the sound switch position. The threshold value for acoustic signaling can be set to 1, 10, 20, 30, 40 or 90 Ω.

Automatic/manual measuring range selection

Measured quantities are selected with the rotary switch. The measuring range can be automatically matched to the measured value or selected manually for quick, repetitive measurements.

Color graphic display

A high-resolution transmissive 3½" TFT color graphic display with 320 x 480 dots is used for measured values and menu navigation. The display is easily readable from all directions, as well as under difficult lighting conditions (controllable with light sensor). Graphic representation permits user-friendly menu navigation including help texts.

Analog bar graph for quick trend displays

The bar graph (with additional negative axis range for zero-frequency quantities) permits faster detection of measured value changes as compared with digital value displays.

Automatic storage of measured values

The data hold function automates the storage of measured values after they have settled in. A patented process assures that random values are not saved to memory in the case of rapidly changing measured quantities, but rather the actual measured value. The stored measured value is displayed as a digital value. The bar graph continuously indicates the momentary measured value.

Overload protection

Overload protection safeguards the instrument in all measuring functions for up to 1000 V. Voltages of greater than 1000 V and currents of greater than 1 A are indicated acoustically. Fuse appears at the display if the fuse for the current or mΩ measurement input blows.

Battery charge level – power saving circuit

The battery charge level is accurately indicated in the graphic display. This device is switched off automatically if the measured value remains unchanged for a period of between 10 and 59 minutes (adjustable) if none of the controls are activated during this time and continuous operation is not activated.

Automatic blocking sockets (ABS)

All current ranges are implemented via a single connector jack which prevents any possibility of operator error. The automatic blocking sockets prevent incorrect connection of the measurement cables, as well as a selection of the wrong measured quantity. Danger to the user, the instrument, and the device under test resulting from operator error is thus ruled out. Patented (patent number EP 1801 598 and US 7,439,725)

Housing and protective cover for harsh conditions

  • New housing design
  • Separate fuse compartment
  • Quick-change rechargeable battery

This instrument is protected against damage in the event of impacts or dropping by means of a soft rubber cover with a tilt stand. The rubber material also assures that the instrument doesn't move if it's set up on a vibrating surface.

Data interfaces

This instrument can be remote and momentary and saved measurement data can be read out via Bluetooth. For PC, the complete software IZYTRONIQ or METRAHIT IM Data Reader is required to this end.

DAkkS calibration certificate

This multimeter is furnished with a DAkkS calibration certificate, which is also recognized internationally (EA, ILAC). After the user-specified calibration interval has elapsed (recommended interval: 1 to 3 years), the multimeter can be inexpensively recalibrated in our proprietary DAkkS calibration laboratory.

Applications

  • Maintenance
  • Service and diagnostics at electric machines
  • Drive units and systems
  • Automotive
  • Avionics
  • Energy
  • Automation
  • Safety testing
  • Diagnostics at electrical and hybrid vehicles
  • All types of electric machines
  • Aviation technology
  • Test and measurement in laboratories and test fields

Spécifications pour le Gossen Metrawatt METRAHIT IM XTRA BT

Resistance Up to 3.1 GΩ
Test Voltages 50 to 1000 V
Display Type TFT color graphic display (55 x 36 mm)
Data Interface Type: Bluetooth 4.2
Frequency band: 2.402 ... 2.480 GHz
Transmitting power: Maximum 91 mW
Functions: Query measuring functions, parameters, momentary measurement data
Memory Capacity 64 MBit for approximately 300,000 measured values with indication of date and time
Analog Bar Graph Scaling: Linear
Polarity display: With automatic switching
Measuring rate: 40 measurements per second and display refresh
Digital Measured Value Display Number of places: 31,000 / 3100 4¾-place in the V, A, Hz and Ω measuring functions, depending on parameter setting
Overflow display: “OL” is displayed for ≥31,000 digits or ≥3100 digits
Measuring rate: 2 times per second, ever 500 ms
Ambient Conditions Accuracy: 32 to 104°F (0 to 40°C)
Storage: 14 to 122°F (-10 to 50°C) with batteries
-4 to 122°F (-20 to 50°C) with rubber holster
-13 to 158°F (-25 to 70°C) without batteries
Relative Humidity 40 to 75%, no condensation allowed
Elevation To 6561.68' (2000 m)
Deployment Indoors, except within specified ambient conditions
Power Source Battery powered
Battery Life Approximately 20 hours
Housing Material Impact resistant plastic (ABS)
Dimensions 9.25 x 4.13 x 2.20" (235 × 105 × 56 mm), without rubber holster
Weight 1.5 lbs (0.7 kg)

Le Gossen Metrawatt METRAHIT IM XTRA BT comprend

  • Multimeter with Rubber Holster
  • DAkkS Calibration Certificate
  • Rechargeable Lithium Polymer Battery with USB Power Pack
  • USB Charger
  • Probe
  • Cable Set
  • 2 x Kelvin Clips
  • Hard Case
  • Card with Registration Key for Software
  • Condensed Operating Instructions
  • 36-Month Materials and Workmanship Warranty; One-Year Calibration Warranty

Cliquer sur une catégorie pour voir une sélection d'accessoires compatible avec le Gossen Metrawatt METRAHIT IM XTRA BT Multimeter with bluetooth, 50 to 1000 V, 0 to 3.1 gΩ.

Gossen Metrawatt Z3409 Capteur de température de surface et d'immersion pour multimètres M249 A, -40 à 600°C Z3409
Conçu pour être utilisé avec le multimètre Gossen Metrawatt M249 A, ce capteur de température standard vous permet d'effectuer des mesures de surface et d'immersion de -40 à 600°C (-40 à 1112°F).




Gossen Metrawatt Z102E Capteur de température de surface avec thermocouple de type K, -50 à 400°C Z102E
Le capteur de température de surface est conçu pour des temps de réaction rapides. Il est doté d'une gaine extérieure en PVC.




Gossen Metrawatt Z102C Sonde de température d'huile à jauge pour applications automobiles, pt 1000, -50 à 500°C Z102C
Utilisez cette sonde de température pour vérifier la température de l'huile automobile. Elle présente une conception de type jauge.




Gossen Metrawatt TF550 Capteur de température à immersion pour fours et congélateurs pour multimètres M249 A, -50 à 550°C TF550
Ce capteur de température standard vous permet de prendre des mesures de -50 à 550°C (-58 à 1022°F) dans un four ou un congélateur à l'aide de votre multimètre Gossen Metrawatt M249 A.




Gossen Metrawatt TF220 Capteur de température à immersion pour gaz et liquides pour multimètres M249 A, -50 à 220°C TF220
Prenez des mesures de gaz et de liquides de -50 à 220°C (-58 à 428°F) avec ce capteur de température standard, compatible avec le multimètre Gossen Metrawatt M249 A.




Gossen Metrawatt Z227A KC4 Pince Kelvin, diamètre jusqu'à 30 mm Z227A
Les pinces Kelvin sont utilisées pour connecter des résistances à faible impédance (p. ex. résistances de contact, shunts, etc.) à un ohmmètre avec une connexion à 4 fils. Cela permet de compenser la résistance du câble. Le KC4 se compose d'une paire de pinces avec des bornes normales.




Gossen Metrawatt Z219B WZ12B Current Sensor Clamp, 10 mA to 100 AAC, 100 mV/A Z219B
Equipped with a top quality metal core which reduces eddy-current loss, and allows for accurate measuring results even with low primary current.




Gossen Metrawatt Z203B CP1100 Pince ampèremétrique CA/CC, 0.5 à 100, 5 à 1000 A /CC, 10 mV /A, 1 mV /A CA/CC Z203B
Ce capteur de courant est un instrument de haute performance pour la mesure des onduleurs, des blocs d'alimentation à découpage, des systèmes de contrôle industriel et d'autres applications nécessitant une mesure de courant ou une analyse de forme d'onde.




Gossen Metrawatt Z202B Pince ampèremétrique CA/CC CP330, 0.5 à 30/5 à 300 A CA/CC, 10 mV/A CA/CC, 1 mV/A CA/CC Z202B
Ce capteur de courant est un instrument de haute performance pour la mesure des onduleurs, des alimentations à découpage, des systèmes de contrôle industriel et d'autres applications nécessitant une mesure de courant ou une analyse de forme d'onde.




Gossen Metrawatt Z201B CP30 Pince capteur de courant CA/CC, 5 mA à 30 A /cc, 100 mV /a CA/CC Z201B
Ce capteur de courant est un instrument de haute performance pour la mesure des onduleurs, des blocs d'alimentation à découpage, des systèmes de contrôle industriel et d'autres applications nécessitant une mesure de courant ou une analyse de forme d'onde.




Gossen Metrawatt Z204A AC/DC Current Sensor Clamp with Voltage Output for METRAHIT TRMS Multimeters, 1800 A Z204A
The current sensor clamp accurately measures AC, DC and complex waveform currents without contact. The sensor clamp is designed for use with TRMS multimeters.




Gossen Metrawatt Z110W Ensemble de câbles KS-NTS avec différentes sondes d'essai, 20 A, 1000 V/CAT III Z110W
L'ensemble de fils comprend des sondes, des pinces et des sondes USA, 1000 V/CAT II/III 20 A. Veuillez vérifier si l'ensemble de câbles est conforme à la sécurité électrique et aux conditions ambiantes de l'environnement dans lequel votre instrument de mesure est utilisé.




Gossen Metrawatt Z110P Ensemble de fils d'essai KS17-S, 1000 V / CAT II, 150 cm Z110P
Ensemble de fils avec sondes de 2 mm (0.08"), l = 120 cm (120'), 1000 V / CAT II.




Gossen Metrawatt GTY3620034P0002 Measurement Cable Set GTY3620034P0002
KS 17-2 cable set consists of two measurement cables with permanently attached test probes at one end, and contact-protected angle plugs at the other end.




Gossen Metrawatt Z117A Support de multimètre METRAHIT HIT-Clip
Le support de multimètre vous permet de suspendre votre appareil METRAHIT pour un transport mains libres. L'étui en caoutchouc protège votre instrument.




Gossen Metrawatt Z227C Kelvin Cable Set, 0.16" angle plugs, 47.24" cable KC&S
The Kelvin cable set connects low-impedance resistors to your ohmmeter via 4-wire connection. It includes a Kelvin clip and probe.




Gossen Metrawatt Z110J Alligator Clips for KS17-2 cable set, 1,000 V, 2-pack KY 95-3
The alligator clips are designed for use with the KS17-2 cable set and your ohmmeter. The clips are color coded for information at a glance.




Gossen Metrawatt Z102T Adaptateur de multimètre fiche banane vers prise miniature Z3431-TA
L'adaptateur vous permet de connecter des appareils dotés d'une fiche banane à des prises miniatures. Il est conçu pour être utilisé avec votre multimètre afin d'obtenir des résultats optimaux.




Gossen Metrawatt Z227B KC27 Kelvin Probe Z227B
Kelvin probes are used for connecting low impedance resistors (e.g. contact resistors, shunts etc.) to an ohmmeter with 4-wire connection. This allows for compensation of cable resistance. KC27 consists of 2 probes with stainless steel tips.




Poser une question sur le Gossen Metrawatt METRAHIT IM XTRA BT Multimeter with bluetooth, 50 to 1000 V, 0 to 3.1 gΩ

Gossen Metrawatt METRAHIT IM XTRA BT offre

Portable and rugged, take multiple measurements with this multimeter well suited for applications such as service and diagnostics at electric machines, maintenance, automotive, safety testing, and more.

Caractéristiques

  • An all-in-one high resoltuion instrument with 30,000 digits: milliohmmeter, multimeter, data logger, insulation resistance tester and coil tester
  • Compact and multifunctional
  • Safety-relevant tests for electric devices, drives and installations with a single field instrument
  • Testing of high-voltage systems in accordance with UN ECE R100
  • Insulation resistance measurement per EN 61557-2 / VDE 0413-2
  • Rlow installation testing per EN 61557-4 / VDE 0413-4
  • Bonding test and equipotential bonding measurement, e.g. on aircraft outer skins (lightning protection, wick test)
  • Insulation resistance measurement up to 3.1 GΩ with interference voltage detection, test voltages: 50, 100, 250, 500 and 1000 V per EN 61557-2
  • DAR: dielectric absorption rate, PI: polarization index
  • Short-circuited coil test with 1000 V
  • Multifunctional measuring instrument (V, A, Ω, F, Hz, °F/°C, %)
  • TRMS AC / AC+DC measurement for current/voltage value up to 10/100 kHz
  • Capacitance measurement
  • Precision temperature measurement °F, and °C for RTD and TC-K sensors
  • Data logger thanks to integrated memory module and real-time clock, individual measurements as well
  • Programmable sequences for test routines
  • Color graphic display
  • Modular power supply: standard quick-change rechargeable lithium battery, change without interrupting the measuring circuit thanks to touch protected module socket
  • Automatic blocking sockets for the current input
  • Test probe with START (ISO) and STORE keys
  • Housing with IP52 protection, dust protected and drip-proof, replaceable rubber holster
  • Interfaces: Bluetooth
  • IZYTRONIQ windows software for documentation, preparation of test reports
  • Display resolution: high resolution with 30,000 digits and a basic accuracy of 0.15%

Insulation resistance measurement with interference voltage detection

Insulation resistance measurement with test voltages of 50 to 1000 V. If interference voltage of greater than 15 V AC or 25 V DC is detected during insulation measurement, the device issues an optical and acoustic warning whereupon measurements cannot be launched. Afterward, automatic switching to TRMSAC+DC voltage measurement at 1 MΩ takes place and the currently measured voltage is displayed as Uext.

Polarization index (PI)

When test voltage is applied, insulation resistance is measured after one minute and after ten minutes. The polarization index is the ratio that results from the two measured values. In the case of electric drive units, a value of at least two indicates intact insulation and a value of greater than 4 indicates very good insulation.

Absorption index (DAR)

Practically speaking, the absorption index test is a quick polarization index measurement. The ISO values measured after 30 and 60 seconds are used to generate a ratio.

Kelvin connection for 4-Wire measurement (4-L) (milliohm measurement)

The 4-wire measurement compensates for influences resulting from cable and contact resistances which must not be neglected when measuring very small resistances. Measuring current can be set to 200 mA or 1 A. In this way, even extremely small contact resistances can be measured, for example at welded and riveted joints and on aircraft outer skins (lightning protection and wick test), or equipotential bonding is measured in accordance with UN ECE R100 in hybrid and electric vehicles.

2-Wire Rlo measurement with 200 mA test current per EN 61557

Low-resistance measurement per EN 61557-4 for earth, protective and equipotential bonding conductors. If excessive interference current is detected during insulation measurement, the device issues an optical and acoustic warning whereupon measurements cannot be launched.

RMS value with distorted waveforms

The utilized measuring method allows for waveform-independent TRMS measurement of alternating quantities (AC) and pulsating quantities (AC and DC) for voltage and current at up to 100 kHz.

Activatable filter for V AC measurement

A 1 kHz low-pass filter can be activated if required, for example when measuring cables with parasitic external signals. The input signal is checked by a voltage comparator for dangerous voltages as long as the low-pass filter is activated, and these are indicated at the display if applicable.

Diode testing with constant current Ik = 1 mA

Testing of the polarity of diodes and checking for short-circuits and interruptions in electrical circuits. The test voltage source makes it possible to measure LEDs and reference diodes up to 4.5 V, e.g. also white LEDs.

Fast Acoustic Continuity Test Ik = 1 mA

Testing for short-circuiting or interruption in the sound switch position. The threshold value for acoustic signaling can be set to 1, 10, 20, 30, 40 or 90 Ω.

Automatic/manual measuring range selection

Measured quantities are selected with the rotary switch. The measuring range can be automatically matched to the measured value or selected manually for quick, repetitive measurements.

Color graphic display

A high-resolution transmissive 3½" TFT color graphic display with 320 x 480 dots is used for measured values and menu navigation. The display is easily readable from all directions, as well as under difficult lighting conditions (controllable with light sensor). Graphic representation permits user-friendly menu navigation including help texts.

Analog bar graph for quick trend displays

The bar graph (with additional negative axis range for zero-frequency quantities) permits faster detection of measured value changes as compared with digital value displays.

Automatic storage of measured values

The data hold function automates the storage of measured values after they have settled in. A patented process assures that random values are not saved to memory in the case of rapidly changing measured quantities, but rather the actual measured value. The stored measured value is displayed as a digital value. The bar graph continuously indicates the momentary measured value.

Overload protection

Overload protection safeguards the instrument in all measuring functions for up to 1000 V. Voltages of greater than 1000 V and currents of greater than 1 A are indicated acoustically. Fuse appears at the display if the fuse for the current or mΩ measurement input blows.

Battery charge level – power saving circuit

The battery charge level is accurately indicated in the graphic display. This device is switched off automatically if the measured value remains unchanged for a period of between 10 and 59 minutes (adjustable) if none of the controls are activated during this time and continuous operation is not activated.

Automatic blocking sockets (ABS)

All current ranges are implemented via a single connector jack which prevents any possibility of operator error. The automatic blocking sockets prevent incorrect connection of the measurement cables, as well as a selection of the wrong measured quantity. Danger to the user, the instrument, and the device under test resulting from operator error is thus ruled out. Patented (patent number EP 1801 598 and US 7,439,725)

Housing and protective cover for harsh conditions

  • New housing design
  • Separate fuse compartment
  • Quick-change rechargeable battery

This instrument is protected against damage in the event of impacts or dropping by means of a soft rubber cover with a tilt stand. The rubber material also assures that the instrument doesn't move if it's set up on a vibrating surface.

Data interfaces

This instrument can be remote and momentary and saved measurement data can be read out via Bluetooth. For PC, the complete software IZYTRONIQ or METRAHIT IM Data Reader is required to this end.

DAkkS calibration certificate

This multimeter is furnished with a DAkkS calibration certificate, which is also recognized internationally (EA, ILAC). After the user-specified calibration interval has elapsed (recommended interval: 1 to 3 years), the multimeter can be inexpensively recalibrated in our proprietary DAkkS calibration laboratory.

Applications

  • Maintenance
  • Service and diagnostics at electric machines
  • Drive units and systems
  • Automotive
  • Avionics
  • Energy
  • Automation
  • Safety testing
  • Diagnostics at electrical and hybrid vehicles
  • All types of electric machines
  • Aviation technology
  • Test and measurement in laboratories and test fields

Spécifications pour le Gossen Metrawatt METRAHIT IM XTRA BT

Resistance Up to 3.1 GΩ
Test Voltages 50 to 1000 V
Display Type TFT color graphic display (55 x 36 mm)
Data Interface Type: Bluetooth 4.2
Frequency band: 2.402 ... 2.480 GHz
Transmitting power: Maximum 91 mW
Functions: Query measuring functions, parameters, momentary measurement data
Memory Capacity 64 MBit for approximately 300,000 measured values with indication of date and time
Analog Bar Graph Scaling: Linear
Polarity display: With automatic switching
Measuring rate: 40 measurements per second and display refresh
Digital Measured Value Display Number of places: 31,000 / 3100 4¾-place in the V, A, Hz and Ω measuring functions, depending on parameter setting
Overflow display: “OL” is displayed for ≥31,000 digits or ≥3100 digits
Measuring rate: 2 times per second, ever 500 ms
Ambient Conditions Accuracy: 32 to 104°F (0 to 40°C)
Storage: 14 to 122°F (-10 to 50°C) with batteries
-4 to 122°F (-20 to 50°C) with rubber holster
-13 to 158°F (-25 to 70°C) without batteries
Relative Humidity 40 to 75%, no condensation allowed
Elevation To 6561.68' (2000 m)
Deployment Indoors, except within specified ambient conditions
Power Source Battery powered
Battery Life Approximately 20 hours
Housing Material Impact resistant plastic (ABS)
Dimensions 9.25 x 4.13 x 2.20" (235 × 105 × 56 mm), without rubber holster
Weight 1.5 lbs (0.7 kg)

Le Gossen Metrawatt METRAHIT IM XTRA BT comprend

  • Multimeter with Rubber Holster
  • DAkkS Calibration Certificate
  • Rechargeable Lithium Polymer Battery with USB Power Pack
  • USB Charger
  • Probe
  • Cable Set
  • 2 x Kelvin Clips
  • Hard Case
  • Card with Registration Key for Software
  • Condensed Operating Instructions
  • 36-Month Materials and Workmanship Warranty; One-Year Calibration Warranty

Cliquer sur une catégorie pour voir une sélection d'accessoires compatible avec le Gossen Metrawatt METRAHIT IM XTRA BT Multimeter with bluetooth, 50 to 1000 V, 0 to 3.1 gΩ.

Gossen Metrawatt Z3409 Capteur de température de surface et d'immersion pour multimètres M249 A, -40 à 600°C Z3409
Conçu pour être utilisé avec le multimètre Gossen Metrawatt M249 A, ce capteur de température standard vous permet d'effectuer des mesures de surface et d'immersion de -40 à 600°C (-40 à 1112°F).




Gossen Metrawatt Z102E Capteur de température de surface avec thermocouple de type K, -50 à 400°C Z102E
Le capteur de température de surface est conçu pour des temps de réaction rapides. Il est doté d'une gaine extérieure en PVC.




Gossen Metrawatt Z102C Sonde de température d'huile à jauge pour applications automobiles, pt 1000, -50 à 500°C Z102C
Utilisez cette sonde de température pour vérifier la température de l'huile automobile. Elle présente une conception de type jauge.




Gossen Metrawatt TF550 Capteur de température à immersion pour fours et congélateurs pour multimètres M249 A, -50 à 550°C TF550
Ce capteur de température standard vous permet de prendre des mesures de -50 à 550°C (-58 à 1022°F) dans un four ou un congélateur à l'aide de votre multimètre Gossen Metrawatt M249 A.




Gossen Metrawatt TF220 Capteur de température à immersion pour gaz et liquides pour multimètres M249 A, -50 à 220°C TF220
Prenez des mesures de gaz et de liquides de -50 à 220°C (-58 à 428°F) avec ce capteur de température standard, compatible avec le multimètre Gossen Metrawatt M249 A.




Gossen Metrawatt Z227A KC4 Pince Kelvin, diamètre jusqu'à 30 mm Z227A
Les pinces Kelvin sont utilisées pour connecter des résistances à faible impédance (p. ex. résistances de contact, shunts, etc.) à un ohmmètre avec une connexion à 4 fils. Cela permet de compenser la résistance du câble. Le KC4 se compose d'une paire de pinces avec des bornes normales.




Gossen Metrawatt Z219B WZ12B Current Sensor Clamp, 10 mA to 100 AAC, 100 mV/A Z219B
Equipped with a top quality metal core which reduces eddy-current loss, and allows for accurate measuring results even with low primary current.




Gossen Metrawatt Z203B CP1100 Pince ampèremétrique CA/CC, 0.5 à 100, 5 à 1000 A /CC, 10 mV /A, 1 mV /A CA/CC Z203B
Ce capteur de courant est un instrument de haute performance pour la mesure des onduleurs, des blocs d'alimentation à découpage, des systèmes de contrôle industriel et d'autres applications nécessitant une mesure de courant ou une analyse de forme d'onde.




Gossen Metrawatt Z202B Pince ampèremétrique CA/CC CP330, 0.5 à 30/5 à 300 A CA/CC, 10 mV/A CA/CC, 1 mV/A CA/CC Z202B
Ce capteur de courant est un instrument de haute performance pour la mesure des onduleurs, des alimentations à découpage, des systèmes de contrôle industriel et d'autres applications nécessitant une mesure de courant ou une analyse de forme d'onde.




Gossen Metrawatt Z201B CP30 Pince capteur de courant CA/CC, 5 mA à 30 A /cc, 100 mV /a CA/CC Z201B
Ce capteur de courant est un instrument de haute performance pour la mesure des onduleurs, des blocs d'alimentation à découpage, des systèmes de contrôle industriel et d'autres applications nécessitant une mesure de courant ou une analyse de forme d'onde.




Gossen Metrawatt Z204A AC/DC Current Sensor Clamp with Voltage Output for METRAHIT TRMS Multimeters, 1800 A Z204A
The current sensor clamp accurately measures AC, DC and complex waveform currents without contact. The sensor clamp is designed for use with TRMS multimeters.




Gossen Metrawatt Z110W Ensemble de câbles KS-NTS avec différentes sondes d'essai, 20 A, 1000 V/CAT III Z110W
L'ensemble de fils comprend des sondes, des pinces et des sondes USA, 1000 V/CAT II/III 20 A. Veuillez vérifier si l'ensemble de câbles est conforme à la sécurité électrique et aux conditions ambiantes de l'environnement dans lequel votre instrument de mesure est utilisé.




Gossen Metrawatt Z110P Ensemble de fils d'essai KS17-S, 1000 V / CAT II, 150 cm Z110P
Ensemble de fils avec sondes de 2 mm (0.08"), l = 120 cm (120'), 1000 V / CAT II.




Gossen Metrawatt GTY3620034P0002 Measurement Cable Set GTY3620034P0002
KS 17-2 cable set consists of two measurement cables with permanently attached test probes at one end, and contact-protected angle plugs at the other end.




Gossen Metrawatt Z117A Support de multimètre METRAHIT HIT-Clip
Le support de multimètre vous permet de suspendre votre appareil METRAHIT pour un transport mains libres. L'étui en caoutchouc protège votre instrument.




Gossen Metrawatt Z227C Kelvin Cable Set, 0.16" angle plugs, 47.24" cable KC&S
The Kelvin cable set connects low-impedance resistors to your ohmmeter via 4-wire connection. It includes a Kelvin clip and probe.




Gossen Metrawatt Z110J Alligator Clips for KS17-2 cable set, 1,000 V, 2-pack KY 95-3
The alligator clips are designed for use with the KS17-2 cable set and your ohmmeter. The clips are color coded for information at a glance.




Gossen Metrawatt Z102T Adaptateur de multimètre fiche banane vers prise miniature Z3431-TA
L'adaptateur vous permet de connecter des appareils dotés d'une fiche banane à des prises miniatures. Il est conçu pour être utilisé avec votre multimètre afin d'obtenir des résultats optimaux.




Gossen Metrawatt Z227B KC27 Kelvin Probe Z227B
Kelvin probes are used for connecting low impedance resistors (e.g. contact resistors, shunts etc.) to an ohmmeter with 4-wire connection. This allows for compensation of cable resistance. KC27 consists of 2 probes with stainless steel tips.




Poser une question sur le Gossen Metrawatt METRAHIT IM XTRA BT Multimeter with bluetooth, 50 to 1000 V, 0 to 3.1 gΩ

Plus de produits Gossen Metrawatt