Fluke i30 AC/DC Current Clamp

Modèle: I30 | CUP: 095969345095

Fluke i30 AC/DC Current Clamp

Modèle: I30 | CUP: 095969345095

Hall Effect technology. Features a Current range of 20A, a measuring range of ±30A, and an Output of 100 mV/A.

Hall Effect technology. Features a Current range of 20A, a measuring range of ±30A, and an Output of 100 mV/A.

Prix spécial $782.72 CAD
Prix régulier $960.39 CAD
Disponibilité 2 en inventaire
Quantité

Traceable Calibration Certificate Icon

Certificat d’étalonnage de traçabilité pour votre I30 AC/DC Current Clamp

Traceable Calibration Certificate Icon

Certificat d’étalonnage de traçabilité pour votre I30 AC/DC Current Clamp

Fluke I30 Offers

The Fluke i30 current clamp is based on Hall Effect technology for use in measurement of both DC and AC current. The i30 may be used in conjunction with multimeters, recorders and other suitable recording instruments for accurate non-intrusive current measurement.

Fluke I30 Specifications

Electrical specifications
Current range

20 A ac rms or dc
Measuring range

± 30 A
Output sensitivity

100 mV/A
Accuracy (at +25 °C)

± 1 % of reading ± 2 mA
Resolution

± 1 mA
Load impedance

> 10 k Ohms and ≤ 100pF
Conductor position sensitivity

± 1 % relative to center reading
Frequency range

DC to 20 kHz (- 0.5 dB)
Temperature coefficient

± 0.01 % of reading/°C
Power supply

9 V Alkaline, MN1604/PP3, 30 hours, low battery indicator
Working voltage (see Safety Standards section)

300 V ac rms or dc
General Specifications
Maximum conductor size

19 mm diameter
Output connection

4 mm safety connector
Output zero

Manual adjust via thumbwheel
Cable length

1.5 meters
Operating temperature range

0 °C to +50 °C
Storage temperature range (with battery removed)

-20 °C to +85 °C
Operating humidity

15 % to 85 % (non-condensing)
Weight

250 g
Safety standards

BS EN 61010-1:2001

BS EN 61010-2-032:2002

BS EN 61010-031:2002

300 Vrms, Category III, Pollution Degree 2

Use of the probe on uninsulated conductors is limited to 300 V ac rms or dc and frequencies below 1 kHz.
EMC Standards

EN 61326: 1998 +A1, A2, & A3

Le Fluke I30 comprend

  • Fluke i30 AC/DC Current Clamp

Cliquer sur une catégorie pour voir une sélection d'accessoires compatible avec le Fluke i30 AC/DC Current Clamp.

Fluke TB25 Sac de rangement pour seau à outils, 5.2 gal TB25
Durable et robuste, ce sac de rangement de seau à outils a une capacité de 5.2 gallons sur laquelle on peut compter pour protéger et transporter en toute sécurité une variété d'outils et d'accessoires de test. Avec sa coque à fond rigide imperméable, cet organisateur polyvalent possède un total de 28 poches qui peuvent s'adapter aux outils à main, aux multimètres numériques, aux pinces ampèremétriques, aux sondes d'essai et plus encore.




Poser une question sur le Fluke i30 AC/DC Current Clamp

Fluke I30 Offers

The Fluke i30 current clamp is based on Hall Effect technology for use in measurement of both DC and AC current. The i30 may be used in conjunction with multimeters, recorders and other suitable recording instruments for accurate non-intrusive current measurement.

Fluke I30 Specifications

Electrical specifications
Current range

20 A ac rms or dc
Measuring range

± 30 A
Output sensitivity

100 mV/A
Accuracy (at +25 °C)

± 1 % of reading ± 2 mA
Resolution

± 1 mA
Load impedance

> 10 k Ohms and ≤ 100pF
Conductor position sensitivity

± 1 % relative to center reading
Frequency range

DC to 20 kHz (- 0.5 dB)
Temperature coefficient

± 0.01 % of reading/°C
Power supply

9 V Alkaline, MN1604/PP3, 30 hours, low battery indicator
Working voltage (see Safety Standards section)

300 V ac rms or dc
General Specifications
Maximum conductor size

19 mm diameter
Output connection

4 mm safety connector
Output zero

Manual adjust via thumbwheel
Cable length

1.5 meters
Operating temperature range

0 °C to +50 °C
Storage temperature range (with battery removed)

-20 °C to +85 °C
Operating humidity

15 % to 85 % (non-condensing)
Weight

250 g
Safety standards

BS EN 61010-1:2001

BS EN 61010-2-032:2002

BS EN 61010-031:2002

300 Vrms, Category III, Pollution Degree 2

Use of the probe on uninsulated conductors is limited to 300 V ac rms or dc and frequencies below 1 kHz.
EMC Standards

EN 61326: 1998 +A1, A2, & A3

Le Fluke I30 comprend

  • Fluke i30 AC/DC Current Clamp

Cliquer sur une catégorie pour voir une sélection d'accessoires compatible avec le Fluke i30 AC/DC Current Clamp.

Fluke TB25 Sac de rangement pour seau à outils, 5.2 gal TB25
Durable et robuste, ce sac de rangement de seau à outils a une capacité de 5.2 gallons sur laquelle on peut compter pour protéger et transporter en toute sécurité une variété d'outils et d'accessoires de test. Avec sa coque à fond rigide imperméable, cet organisateur polyvalent possède un total de 28 poches qui peuvent s'adapter aux outils à main, aux multimètres numériques, aux pinces ampèremétriques, aux sondes d'essai et plus encore.




Poser une question sur le Fluke i30 AC/DC Current Clamp

Plus de produits Fluke