Fluke Networks MFTK1200 MultiFiber Pro Testing Base Kit

Modèle: MFTK1200 | CUP: 754082092742

Fluke Networks MFTK1200 MultiFiber Pro Testing Base Kit

Modèle: MFTK1200 | CUP: 754082092742

Features MultiFiber Pro Power Meter, 850 Light Source, Test Cords and MPO adapters.

Features MultiFiber Pro Power Meter, 850 Light Source, Test Cords and MPO adapters.

Votre prix $21162.95 CAD
Disponibilité 3 à 4 semaines
Quantité
Add Gold Support to your MFTK1200

Choisissez parmi ces options

Effacer les options sélectionnées

Add Gold Support to your MFTK1200

Choisissez parmi ces options

Effacer les options sélectionnées


Fluke Networks MFTK1200 offre

Applications

  • Surveillance et entretien des centres de données

Features


"Scan All" Function

The Scan All function in the MultiFiber Pro Power Meter automatically scans and tests all 12 fibers in MPO connectors - taking just 6 seconds to complete all loss or power measurements. This feature automates the testing of MPO terminated fibers and eliminates the time consuming and manual process of moving the fiber tester from fiber to fiber while using fan-out cords.


Built-in Polarity Verification

The simple purpose of any polarity scheme is to provide a continuous connection from the link's transmitter to the link's receiver. For array connectors, TIA-568-C.0 defines three methods to accomplish this: Methods A, B and C. Deployment mistakes are common because these methods require a combination of patch cords with different polarity types. The polarity measurement of MultiFiber Pro allows the user to test individual patch cords, permanent links and channels for correct polarity.


On-board MPO Connector

Equipped with MPO connector on both the Optical Power Meter and Light Source, it eliminates the use of costly and complicated fan-out cords to test MPO fibers.


Simple User Interface

The MultiFiber Pro is so successful at simplifying the task of simultaneously representing polarity, power and loss results for 12 fibers that the user interface is patent pending. The power meter enables the users to easily comprehend the measurement results of 12 fibers simultaneously. The light source identifies each fiber within the MPO connector that is being tested. Any individual measurement that fails the test limit is plainly identified to allow root-cause analysis. This powerful yet straightforward test set enables everyone to become a fiber testing expert and increases efficiency in testing data center projects.


Select an Individual Fiber

One of the main problems in the data center is the ability to drill down to a single fiber during testing and troubleshooting. MultiFiber Pro can troubleshoot a single fiber within an MPO trunk and provide a single fiber test result. This ability increases MPO connector verification and troubleshooting flexibility with more precise, per-fiber data and reporting.


On-board Shuttered MPO Connector

Uncovered ports can put cabling, equipment and testers at risk for contamination and affect performance. Ensuring a covered connection on your tester can protect it from dirt and dust. MultiFiber Pro makes it easy by shuttering the MPO connector giving you greater test reliability and peace of mind.


Easy Reporting

The MultiFiber Pro Power Meter stores up to 3,000 test results (or the equivalent of 250 MPO cables) internally which can be uploaded to a PC using the LinkWare™ 7 Cable Test Management Software. LinkWare 7 allows you to manage test results, edit cable ID’s, print professional reports and even export the data into spreadsheet formats.


Kits for Every Need

MultiFiber Pro is available in several convenient kit configurations to meet all your cleaning, inspection and verification testing needs. Some kits include:
Fiber Inspection – FiberInspector™ Pro The FiberInspector Pro is the ultimate inspection tool. Its 3.5” screen provides a larger image from its dual magnification probe. The small probe fits in the palm of your hand and can be switched between 250x and 400x magnification with the turn of a dial. The FiberInspector Pro and optional MPO tip complement the MultiFiber Pro test set to provide a comprehensive kit for cleaning, inspection and testing of MPO connected fibers and cassettes.
Fiber Cleaning – IBC® OneClick Cleaners Cleaning is critical. Fluke Networks’ OneClick Cleaners instantly clean fiber optic bulkhead connectors and end-faces. Just push the tool tip to engage cleaning action and pull back on the wheel – it’s that simple. The MPO OneClick Cleaner is bundled with the MultiFiber Pro kits to ensure that you have the best cleaning tool from the beginning.

Introducing the MultiFiber™ Pro Optical Power Meter and Fiber Test Kits. MultiFiber™ Pro is the only fiber tester that can test MPO fiber trunks without the use of a fan-out cord, it eliminates the complexity of polarity issues, and it makes cassettes easier to test in the field. Whether it is using 10 Gbps pre-terminated fiber trunks or planning for next-generation 40/100 Gbps performance, data centers are standardizing on an MPO connector solution. Typical data center fiber installation means time-consuming, manual and imprecise MPO validation. MultiFiber™ Pro is 90 percent faster than the single fiber testing method because it measures power loss and validates polarity on 12 fibers in a single connector— reducing test time from weeks to days.

Caractéristiques

  • Automatic scanning and testing of all fibers in MPO connectors with "Scan All" function
  • Ensures correct end-to-end connectivity of MPO fiber trunks with built-in polarity verification
  • On-board MPO connector eliminates the need for fan-out cords when testing fiber trunks
  • Easy to interpret test results with minimal navigation – the user interface displays all 12 fibers
  • Troubleshoot MPO links and drill down to single fiber test results
  • No dust caps to manage or lose with a shuttered MPO connector

Spécifications pour le Fluke Networks MFTK1200

Optical Power Meter Specifications
Detector type InGaAs
Calibrated wavelengths 850 nm, 1300 nm, 1310 nm, 1550 nm
Measurement range 0 dBm to -50 dBm
Power measurement linearity ±0.1 dB
Power measurement uncertainty ±0.35 dB
Power measurement repeatability < 0.10 dB</td>
Display resolution, dB or dBm 0.01 dB
Power display units dBm, mW, µW
User-selectable limit for loss 0.05 dB to 50.0 dB, in increments of 0.05 dB up to 10.0 dB and 0.1 dB up to 50.0 dB
Auto wavelength detection Yes
Polarity detection Detects A, B, C, and Corning Plug & Play™ Universal Systems polarities
2 kHz detection Yes
Record storage 3000 records, one fiber per record (250 12-fiber cables)
External interface USB 2.0, full speed
Optical connector MPO interface for 12-fiber, unpinned plugs. Compatible with 50 µm and singlemode fibers. Connector has a self-closing, protective cover.
Power requirement 2 AA alkaline batteries
Battery life >30 hours (typical)
Automatic power-off 10, 20, 30, or 60 minutes (can be disabled by the user)
Low battery warning Low battery icon blinks
Size 5.7 in x 3.2 in x 1.5 in (14.5 cm x 8.0 cm x 3.9 cm)
Weight 10.9 oz (309 g)
850nm Source Specifications
Emitter type LED: 850 nm
Wavelength 850 nm: ±30 nm
Spectral width (FWHM) 850 nm: ±50 nm (typical)
Output power 850 nm: ≥ 24 dBm Max difference between channels +/-1dB
Power output stability ≤ ±0.1 dB over 8 hours
Encircled flux Meets ANSI/TIA-526-14B, ISO/IEC 14763-3, and IEC 61280-4-1 for 50/125 µm at the source’s optical connector.
Optical connector MPO interface for 12-fiber, unpinned plugs. Compatible with 62.5 µm and 50 µm.
Modes 2 kHz modulated, auto wavelength
Power requirement 2 AA alkaline batteries
Battery life >30 hours (typical)
Automatic power-off 10, 20, 30, or 60 minutes (can be disabled by the user)
Low battery warning Low battery icon blinks
Size 5.6 in x 3.2 in x 1.6 in (14.2 cm x 8.1 cm x 4.1 cm)
Weight 10.9 oz (309 g)
General Specifications
Operating temperature -10 to 50°C
Storage temperature -20 to 50°C <10°C</td>
Operating humidity 95% (10 to 35°C) non-condensing
75% (35 to 45°C) non-condensing
Uncontrolled <10°C</td>
Operating altitude 4,000 m
Storage altitude 12,000 m
Vibration Random 2 G, 5 Hz to 500 Hz

Le Fluke Networks MFTK1200 comprend

  • Fluke Networks MFTK1200 MultiFiber Pro Testing Base Kit

Poser une question sur le Fluke Networks MFTK1200 MultiFiber Pro Testing Base Kit

Fluke Networks MFTK1200 offre

Applications

  • Surveillance et entretien des centres de données

Features


"Scan All" Function

The Scan All function in the MultiFiber Pro Power Meter automatically scans and tests all 12 fibers in MPO connectors - taking just 6 seconds to complete all loss or power measurements. This feature automates the testing of MPO terminated fibers and eliminates the time consuming and manual process of moving the fiber tester from fiber to fiber while using fan-out cords.


Built-in Polarity Verification

The simple purpose of any polarity scheme is to provide a continuous connection from the link's transmitter to the link's receiver. For array connectors, TIA-568-C.0 defines three methods to accomplish this: Methods A, B and C. Deployment mistakes are common because these methods require a combination of patch cords with different polarity types. The polarity measurement of MultiFiber Pro allows the user to test individual patch cords, permanent links and channels for correct polarity.


On-board MPO Connector

Equipped with MPO connector on both the Optical Power Meter and Light Source, it eliminates the use of costly and complicated fan-out cords to test MPO fibers.


Simple User Interface

The MultiFiber Pro is so successful at simplifying the task of simultaneously representing polarity, power and loss results for 12 fibers that the user interface is patent pending. The power meter enables the users to easily comprehend the measurement results of 12 fibers simultaneously. The light source identifies each fiber within the MPO connector that is being tested. Any individual measurement that fails the test limit is plainly identified to allow root-cause analysis. This powerful yet straightforward test set enables everyone to become a fiber testing expert and increases efficiency in testing data center projects.


Select an Individual Fiber

One of the main problems in the data center is the ability to drill down to a single fiber during testing and troubleshooting. MultiFiber Pro can troubleshoot a single fiber within an MPO trunk and provide a single fiber test result. This ability increases MPO connector verification and troubleshooting flexibility with more precise, per-fiber data and reporting.


On-board Shuttered MPO Connector

Uncovered ports can put cabling, equipment and testers at risk for contamination and affect performance. Ensuring a covered connection on your tester can protect it from dirt and dust. MultiFiber Pro makes it easy by shuttering the MPO connector giving you greater test reliability and peace of mind.


Easy Reporting

The MultiFiber Pro Power Meter stores up to 3,000 test results (or the equivalent of 250 MPO cables) internally which can be uploaded to a PC using the LinkWare™ 7 Cable Test Management Software. LinkWare 7 allows you to manage test results, edit cable ID’s, print professional reports and even export the data into spreadsheet formats.


Kits for Every Need

MultiFiber Pro is available in several convenient kit configurations to meet all your cleaning, inspection and verification testing needs. Some kits include:
Fiber Inspection – FiberInspector™ Pro The FiberInspector Pro is the ultimate inspection tool. Its 3.5” screen provides a larger image from its dual magnification probe. The small probe fits in the palm of your hand and can be switched between 250x and 400x magnification with the turn of a dial. The FiberInspector Pro and optional MPO tip complement the MultiFiber Pro test set to provide a comprehensive kit for cleaning, inspection and testing of MPO connected fibers and cassettes.
Fiber Cleaning – IBC® OneClick Cleaners Cleaning is critical. Fluke Networks’ OneClick Cleaners instantly clean fiber optic bulkhead connectors and end-faces. Just push the tool tip to engage cleaning action and pull back on the wheel – it’s that simple. The MPO OneClick Cleaner is bundled with the MultiFiber Pro kits to ensure that you have the best cleaning tool from the beginning.

Introducing the MultiFiber™ Pro Optical Power Meter and Fiber Test Kits. MultiFiber™ Pro is the only fiber tester that can test MPO fiber trunks without the use of a fan-out cord, it eliminates the complexity of polarity issues, and it makes cassettes easier to test in the field. Whether it is using 10 Gbps pre-terminated fiber trunks or planning for next-generation 40/100 Gbps performance, data centers are standardizing on an MPO connector solution. Typical data center fiber installation means time-consuming, manual and imprecise MPO validation. MultiFiber™ Pro is 90 percent faster than the single fiber testing method because it measures power loss and validates polarity on 12 fibers in a single connector— reducing test time from weeks to days.

Caractéristiques

  • Automatic scanning and testing of all fibers in MPO connectors with "Scan All" function
  • Ensures correct end-to-end connectivity of MPO fiber trunks with built-in polarity verification
  • On-board MPO connector eliminates the need for fan-out cords when testing fiber trunks
  • Easy to interpret test results with minimal navigation – the user interface displays all 12 fibers
  • Troubleshoot MPO links and drill down to single fiber test results
  • No dust caps to manage or lose with a shuttered MPO connector

Spécifications pour le Fluke Networks MFTK1200

Optical Power Meter Specifications
Detector type InGaAs
Calibrated wavelengths 850 nm, 1300 nm, 1310 nm, 1550 nm
Measurement range 0 dBm to -50 dBm
Power measurement linearity ±0.1 dB
Power measurement uncertainty ±0.35 dB
Power measurement repeatability < 0.10 dB</td>
Display resolution, dB or dBm 0.01 dB
Power display units dBm, mW, µW
User-selectable limit for loss 0.05 dB to 50.0 dB, in increments of 0.05 dB up to 10.0 dB and 0.1 dB up to 50.0 dB
Auto wavelength detection Yes
Polarity detection Detects A, B, C, and Corning Plug & Play™ Universal Systems polarities
2 kHz detection Yes
Record storage 3000 records, one fiber per record (250 12-fiber cables)
External interface USB 2.0, full speed
Optical connector MPO interface for 12-fiber, unpinned plugs. Compatible with 50 µm and singlemode fibers. Connector has a self-closing, protective cover.
Power requirement 2 AA alkaline batteries
Battery life >30 hours (typical)
Automatic power-off 10, 20, 30, or 60 minutes (can be disabled by the user)
Low battery warning Low battery icon blinks
Size 5.7 in x 3.2 in x 1.5 in (14.5 cm x 8.0 cm x 3.9 cm)
Weight 10.9 oz (309 g)
850nm Source Specifications
Emitter type LED: 850 nm
Wavelength 850 nm: ±30 nm
Spectral width (FWHM) 850 nm: ±50 nm (typical)
Output power 850 nm: ≥ 24 dBm Max difference between channels +/-1dB
Power output stability ≤ ±0.1 dB over 8 hours
Encircled flux Meets ANSI/TIA-526-14B, ISO/IEC 14763-3, and IEC 61280-4-1 for 50/125 µm at the source’s optical connector.
Optical connector MPO interface for 12-fiber, unpinned plugs. Compatible with 62.5 µm and 50 µm.
Modes 2 kHz modulated, auto wavelength
Power requirement 2 AA alkaline batteries
Battery life >30 hours (typical)
Automatic power-off 10, 20, 30, or 60 minutes (can be disabled by the user)
Low battery warning Low battery icon blinks
Size 5.6 in x 3.2 in x 1.6 in (14.2 cm x 8.1 cm x 4.1 cm)
Weight 10.9 oz (309 g)
General Specifications
Operating temperature -10 to 50°C
Storage temperature -20 to 50°C <10°C</td>
Operating humidity 95% (10 to 35°C) non-condensing
75% (35 to 45°C) non-condensing
Uncontrolled <10°C</td>
Operating altitude 4,000 m
Storage altitude 12,000 m
Vibration Random 2 G, 5 Hz to 500 Hz

Le Fluke Networks MFTK1200 comprend

  • Fluke Networks MFTK1200 MultiFiber Pro Testing Base Kit

Poser une question sur le Fluke Networks MFTK1200 MultiFiber Pro Testing Base Kit

Plus de produits Fluke Networks