The Fluke 700P02 Differential Pressure Module displays pressure readings in any of 10 different pressure units you specify in the calibrator setup. The pressure module allows you to measure pressure with the Fluke 700 Series Process Calibrators. This differential pressure module has two pressure fittings and measures the difference between the applied pressure on the high fitting versus the low fitting. It functions like a gauge module when the low fitting is open. The pressure module measures pressure using an internal microprocessor.
Caractéristiques
| Specifications | |||||||||||||
| Range |
|
||||||||||||
| 1 psi / 6900 Pa | |||||||||||||
| Resolution |
|
||||||||||||
| 0.0001 / 0.7 | |||||||||||||
| Reference Uncertainty (23 ± 3°C) |
|
||||||||||||
| 0.0015 | |||||||||||||
| Total Uncertainty 1 year |
|
||||||||||||
| 0.3 | |||||||||||||
| High Side Media≤ |
|
||||||||||||
| Dry | |||||||||||||
| Low Side Media≤ |
|
||||||||||||
| Dry | |||||||||||||
| Note |
|
||||||||||||
| 1) | Total uncertainty, one year for temperature range 0°C + 50°C. | ||||||||||||
| Total uncertainty, 1.0% of full span for temperature range - 10°C to 0°C. | |||||||||||||
| Compensated temperature range is 15°C to 35°C. |
|||||||||||||
| 2) | "Dry" indicates dry air or non-corrosive gas as compatible media. | ||||||||||||
| "316 SS" indicates media compatible with Type 316 Stainless Steel. | |||||||||||||
| "C276" indicates media compatible with Hastelloy C276. | |||||||||||||
| Specifications | |||||||||||||
| Range |
|
||||||||||||
| 1 psi / 6900 Pa | |||||||||||||
| Resolution |
|
||||||||||||
| 0.0001 / 0.7 | |||||||||||||
| Reference Uncertainty (23 ± 3°C) |
|
||||||||||||
| 0.0015 | |||||||||||||
| Total Uncertainty 1 year |
|
||||||||||||
| 0.3 | |||||||||||||
| High Side Media≤ |
|
||||||||||||
| Dry | |||||||||||||
| Low Side Media≤ |
|
||||||||||||
| Dry | |||||||||||||
| Note |
|
||||||||||||
| 1) | Total uncertainty, one year for temperature range 0°C + 50°C. | ||||||||||||
| Total uncertainty, 1.0% of full span for temperature range - 10°C to 0°C. | |||||||||||||
| Compensated temperature range is 15°C to 35°C. |
|||||||||||||
| 2) | "Dry" indicates dry air or non-corrosive gas as compatible media. | ||||||||||||
| "316 SS" indicates media compatible with Type 316 Stainless Steel. | |||||||||||||