Fluke 5609-12-M Secondary PRT with Mini Banana Plugs, -200 to 670°C, Calibration Options

Modèle: 5609-12-M | CUP: 095969421386

Fluke 5609-12-M Secondary PRT with Mini Banana Plugs, -200 to 670°C, Calibration Options

Modèle: 5609-12-M | CUP: 095969421386

Designed to perform in extreme environments, this secondary PRT comes equipped with mini banana plug connections.

Designed to perform in extreme environments, this secondary PRT comes equipped with mini banana plug connections.

Votre prix $2464.00 CAD
Disponibilité 2 à 3 semaines
Quantité

Fluke 5609-12-M Offers

Features

  • -328 to 1,238°F (-200 to 670°C) (3.94in (100mm) minimum immersion)
  • ±0.01 short-term stability
  • Calibration not included, NVLAP-accredited calibration optional, lab code 200348-0

Fluke 5609-12-M Specifications

Temperature Range -328 to 1,238°F (-200 to 670°C)
Nominal Resistance at 0.01°C 100Ω ±0.5Ω
Temperature Coefficient 0.0039250Ω/Ω/°C
Short-Term Repeatability ±0.01 at 0.010°C; ±0.02°C at max temp
Drift ±0.01 at 0.010°C; ±0.02°C at max temp
Hysteresis ±0.01°C maximum
Sensor Length 1.2in ±0.2in (30mm ±5mm)
Sensor Location 0.1in ±0.1in (3mm ±1mm from tip)
Minimum Insulation Resistance 500MΩ at 23°C, 10MΩ at 670°C
Transition Junction Dimensions 2.8 x 0.49in (71 x 12.5mm)
Minimum Immersion Length (<5 mK Error) 3.9in (100mm)
Maximum Immersion Length 12in (305mm)
Response Time 12 seconds typical
Self Heating (In 0°C Bath) 50mW/°C
Lead-Wire Cable Type Teflon, 24AWG
Lead-Wire Length 6ft (1.8m)
Lead-Wire Temperature Range -58 to 482°F (-50 to 250°C)
Calibration Calibration not included; NVLAP-accredited calibration optional, lab code 200348-0; please see calibration uncertainty table and its explanation of changeable uncertainties
Cliquer ici pour toutes les spécifications du Fluke 5609-12-M

Le Fluke 5609-12-M comprend

  • Fluke 5609-12-M Secondary PRT with Mini Banana Plugs, -200 to 670°C, Calibration Options

Cliquer sur une catégorie pour voir une sélection d'accessoires compatible avec le Fluke 5609-12-M Secondary PRT with Mini Banana Plugs, -200 to 670°C, Calibration Options.

Fluke TB25 Sac de rangement pour seau à outils, 5.2 gal TB25
Durable et robuste, ce sac de rangement de seau à outils a une capacité de 5.2 gallons sur laquelle on peut compter pour protéger et transporter en toute sécurité une variété d'outils et d'accessoires de test. Avec sa coque à fond rigide imperméable, cet organisateur polyvalent possède un total de 28 poches qui peuvent s'adapter aux outils à main, aux multimètres numériques, aux pinces ampèremétriques, aux sondes d'essai et plus encore.




Poser une question sur le Fluke 5609-12-M Secondary PRT with Mini Banana Plugs, -200 to 670°C, Calibration Options

Fluke 5609-12-M Offers

Features

  • -328 to 1,238°F (-200 to 670°C) (3.94in (100mm) minimum immersion)
  • ±0.01 short-term stability
  • Calibration not included, NVLAP-accredited calibration optional, lab code 200348-0

Fluke 5609-12-M Specifications

Temperature Range -328 to 1,238°F (-200 to 670°C)
Nominal Resistance at 0.01°C 100Ω ±0.5Ω
Temperature Coefficient 0.0039250Ω/Ω/°C
Short-Term Repeatability ±0.01 at 0.010°C; ±0.02°C at max temp
Drift ±0.01 at 0.010°C; ±0.02°C at max temp
Hysteresis ±0.01°C maximum
Sensor Length 1.2in ±0.2in (30mm ±5mm)
Sensor Location 0.1in ±0.1in (3mm ±1mm from tip)
Minimum Insulation Resistance 500MΩ at 23°C, 10MΩ at 670°C
Transition Junction Dimensions 2.8 x 0.49in (71 x 12.5mm)
Minimum Immersion Length (<5 mK Error) 3.9in (100mm)
Maximum Immersion Length 12in (305mm)
Response Time 12 seconds typical
Self Heating (In 0°C Bath) 50mW/°C
Lead-Wire Cable Type Teflon, 24AWG
Lead-Wire Length 6ft (1.8m)
Lead-Wire Temperature Range -58 to 482°F (-50 to 250°C)
Calibration Calibration not included; NVLAP-accredited calibration optional, lab code 200348-0; please see calibration uncertainty table and its explanation of changeable uncertainties
Cliquer ici pour toutes les spécifications du Fluke 5609-12-M

Le Fluke 5609-12-M comprend

  • Fluke 5609-12-M Secondary PRT with Mini Banana Plugs, -200 to 670°C, Calibration Options

Cliquer sur une catégorie pour voir une sélection d'accessoires compatible avec le Fluke 5609-12-M Secondary PRT with Mini Banana Plugs, -200 to 670°C, Calibration Options.

Fluke TB25 Sac de rangement pour seau à outils, 5.2 gal TB25
Durable et robuste, ce sac de rangement de seau à outils a une capacité de 5.2 gallons sur laquelle on peut compter pour protéger et transporter en toute sécurité une variété d'outils et d'accessoires de test. Avec sa coque à fond rigide imperméable, cet organisateur polyvalent possède un total de 28 poches qui peuvent s'adapter aux outils à main, aux multimètres numériques, aux pinces ampèremétriques, aux sondes d'essai et plus encore.




Poser une question sur le Fluke 5609-12-M Secondary PRT with Mini Banana Plugs, -200 to 670°C, Calibration Options

Plus de produits Fluke

Fluke Le prochain est à nos frais!