The transition junction seal and lead wire insulation of this full-immersion PRT won't degrade in common heat transfer fluids, such as silicone oil, mineral oil, ethanol and even liquid nitrogen.

The transition junction seal and lead wire insulation of this full-immersion PRT won't degrade in common heat transfer fluids, such as silicone oil, mineral oil, ethanol and even liquid nitrogen.

Votre prix $1092.00 CAD
Disponibilité 2 à 3 semaines
Quantité

Fluke 5606-50-D Offers

This full-immersion PRT has a calibration accuracy of ±0.05°C.

Features

  • -328 to 320°F (-200 to 160°C)
  • Transition junction and lead wires can withstand full PRT temperature range
  • Unique probe seal of 5606 prevents ingress of moisture
  • Calibration not included; NVLAP-accredited calibration optional

Fluke 5606-50-D Specifications

Temperature Range -328 to 320°F (-200 to 160°C)
Nominal Resistance At 0.01°C 100Ω ±0.1Ω
Temperature Coefficient 0.00385Ω/Ω/°C
Accuracy ±0.04 at 0.01°C; ±0.06 at 160°C
Short-Term Repeatability ±0.03 at 0.01°C; ±0.04 at 160°C
Drift ±0.03 at 0.01°C; ±0.04 at 160°C
Hysteresis ±0.015°C
Sheath Length 1.97in ±0.2in (50mm ±5mm)
Sheath Diameter 0.13in ±0.004in (3.1mm ±0.1mm)
Sheath Material 316 SST
Transition Junction Temperature Range -328 to 320°F (-200 to 160°C)
Sensor Length 1.2in ±0.1 in (30mm ±3mm)
Sensor Location 1.2in ±0.04in (3mm ±1mm from tip)
Minimum Insulation Resistance 20MΩ at 23°C
Minimum Immersion Length Full immersion
Maximum Immersion Depth In Liquid Medium Full immersion
Maximum Immersion Depth In Dry Medium Full immersion
Response Time 12 seconds typical
Self Heating (In 0°C Bath) ±0.003°C
Lead-Wire Cable Type Enameled copper wire
Lead-Wire Length 8ft (2.4m)
Lead-Wire Temperature Range 320°F (160°C)
Calibration Calibration not included. NVLAP accredited calibration available. See ordering information
Cliquer ici pour toutes les spécifications du Fluke 5606-50-D

Le Fluke 5606-50-D comprend

  • Fluke 5606-50-D Full-Immersion PRT with 5-Pin DIN for Tweener Thermometers

Cliquer sur une catégorie pour voir une sélection d'accessoires compatible avec le Fluke 5606-50-D Full-Immersion PRT with 5-Pin DIN for Tweener Thermometers.

Fluke TB25 Sac de rangement pour seau à outils, 5.2 gal TB25
Durable et robuste, ce sac de rangement de seau à outils a une capacité de 5.2 gallons sur laquelle on peut compter pour protéger et transporter en toute sécurité une variété d'outils et d'accessoires de test. Avec sa coque à fond rigide imperméable, cet organisateur polyvalent possède un total de 28 poches qui peuvent s'adapter aux outils à main, aux multimètres numériques, aux pinces ampèremétriques, aux sondes d'essai et plus encore.




Poser une question sur le Fluke 5606-50-D Full-Immersion PRT with 5-Pin DIN for Tweener Thermometers

Fluke 5606-50-D Offers

This full-immersion PRT has a calibration accuracy of ±0.05°C.

Features

  • -328 to 320°F (-200 to 160°C)
  • Transition junction and lead wires can withstand full PRT temperature range
  • Unique probe seal of 5606 prevents ingress of moisture
  • Calibration not included; NVLAP-accredited calibration optional

Fluke 5606-50-D Specifications

Temperature Range -328 to 320°F (-200 to 160°C)
Nominal Resistance At 0.01°C 100Ω ±0.1Ω
Temperature Coefficient 0.00385Ω/Ω/°C
Accuracy ±0.04 at 0.01°C; ±0.06 at 160°C
Short-Term Repeatability ±0.03 at 0.01°C; ±0.04 at 160°C
Drift ±0.03 at 0.01°C; ±0.04 at 160°C
Hysteresis ±0.015°C
Sheath Length 1.97in ±0.2in (50mm ±5mm)
Sheath Diameter 0.13in ±0.004in (3.1mm ±0.1mm)
Sheath Material 316 SST
Transition Junction Temperature Range -328 to 320°F (-200 to 160°C)
Sensor Length 1.2in ±0.1 in (30mm ±3mm)
Sensor Location 1.2in ±0.04in (3mm ±1mm from tip)
Minimum Insulation Resistance 20MΩ at 23°C
Minimum Immersion Length Full immersion
Maximum Immersion Depth In Liquid Medium Full immersion
Maximum Immersion Depth In Dry Medium Full immersion
Response Time 12 seconds typical
Self Heating (In 0°C Bath) ±0.003°C
Lead-Wire Cable Type Enameled copper wire
Lead-Wire Length 8ft (2.4m)
Lead-Wire Temperature Range 320°F (160°C)
Calibration Calibration not included. NVLAP accredited calibration available. See ordering information
Cliquer ici pour toutes les spécifications du Fluke 5606-50-D

Le Fluke 5606-50-D comprend

  • Fluke 5606-50-D Full-Immersion PRT with 5-Pin DIN for Tweener Thermometers

Cliquer sur une catégorie pour voir une sélection d'accessoires compatible avec le Fluke 5606-50-D Full-Immersion PRT with 5-Pin DIN for Tweener Thermometers.

Fluke TB25 Sac de rangement pour seau à outils, 5.2 gal TB25
Durable et robuste, ce sac de rangement de seau à outils a une capacité de 5.2 gallons sur laquelle on peut compter pour protéger et transporter en toute sécurité une variété d'outils et d'accessoires de test. Avec sa coque à fond rigide imperméable, cet organisateur polyvalent possède un total de 28 poches qui peuvent s'adapter aux outils à main, aux multimètres numériques, aux pinces ampèremétriques, aux sondes d'essai et plus encore.




Poser une question sur le Fluke 5606-50-D Full-Immersion PRT with 5-Pin DIN for Tweener Thermometers

Plus de produits Fluke