Fluke 435-II Series of Power Quality Analyzers

Fluke 435-II Series of Power Quality Analyzers-


Plus de produits Fluke

Demander à un expert

Fluke 435-II Series of Power Quality Analyzers

The Power Quality analyzers that can monetize the cost of energy waste due to poor power quality. More powerful sampling options, greater accuracy and larger memory makes the Fluke 435-II better for longer term, higher resolution or more demanding power quality studies. The wide range of measurement functions and measurement methods make it the perfect tool for both power quality troubleshooting and discovering energy savings. Whether you’re checking the performance of motors and generators, trying to discover the source of an intermittent power problem or performing an energy study…this tool gives you the data you need to quickly get to the source of the problem.

The Power Quality analyzers that can monetize the cost of energy waste due to poor power quality. More powerful sampling options, greater accuracy and larger memory makes the Fluke 435-II better for longer term, higher resolution or more demanding power quality studies. The wide range of measurement functions and measurement methods make it the perfect tool for both power quality troubleshooting and discovering energy savings. Whether you’re checking the performance of motors and generators, trying to discover the source of an intermittent power problem or performing an energy study…this tool gives you the data you need to quickly get to the source of the problem.

Discontinué!

Ce produit a été discontinué et n’est plus disponible.

Il n’y a pas de remplacement direct, mais nous vous recommandons:

Fluke 1775 Analyseur de qualité d'énergie triphasé avec sondes de courant et adaptateur WiFi/BLE, 8 kV-

Fluke 1775 Analyseur de qualité d'énergie triphasé avec sondes de courant et adaptateur WiFi/BLE, 8 kV

Modèle: 1775

Ne manquez jamais un événement critique lié à la qualité de l'énergie grâce à cet analyseur de qualité de l'énergie qui mesure de nombreuses variables. En outre, grâce à un écran tactile capacitif utilisable par les EPI, cet analyseur découvre les défaillances d'équipement causées par des transitoires et simplifie l'examen de l'état général de la qualité de l'énergie des systèmes électriques.


Fluke 1775/DE BASE Analyseur de qualité d'énergie triphasé, 8 kV-

Fluke 1775/DE BASE Analyseur de qualité d'énergie triphasé, 8 kV

Modèle: 1775/BASIC

Ne manquez jamais un événement critique lié à la qualité de l'énergie grâce à cet analyseur de qualité de l'énergie qui mesure de nombreuses variables. En outre, grâce à un écran tactile capacitif utilisable par les EPI, cet analyseur détecte les défaillances d'équipement causées par des transitoires et simplifie l'examen de l'état de la qualité de l'énergie des systèmes électriques.


Vous ne trouvez pas ce que vous cherchez? Nous ferons une recherche et vous aiderons à trouver ce dont vous avez besoin.


Accessoires recommandées


Spécifications pour le Fluke 435-II

  ModelMeasurement rangeResolutionAccuracy
Volt
Vrms (ac+dc) 435-II1 V to 1000 V phase to neutral0.01 V± 0.1% of nominal voltage****
Vpk 1 Vpk to 1400 Vpk1 V5% of nominal voltage
Voltage Crest Factor (CF) 1.0 > 2.80.01± 5 %
Vrms½ 435-II0.1 V± 0.2% of nominal voltage
Vfund 435-II0.1 V± 0.1% of nominal voltage
Amps (accuracy excluding clamp accuracy)
Amps (ac +dc) i430-Flex 1x5 A to 6000 A1 A± 0.5% ± 5 counts
  i430-Flex 10x0.5 A to 600 A0.1 A± 0.5% ± 5 counts
  1mV/A 1x5 A to 2000 A1A± 0.5% ± 5 counts
  1mV/A 10x0.5 A A to 200 A (ac only)0.1 A± 0.5% ± 5 counts
Apk i430-Flex8400 Apk1 Arms± 5 %
  1mV/A5500 Apk1 Arms± 5 %
A Crest Factor (CF) 1 to 100.01± 5 %
Amps½ i430-Flex 1x5 A to 6000 A1 A± 1% ± 10 counts
  i430-Flex 10x0.5 A to 600 A0.1 A± 1% ± 10 counts
  1mV/A 1x5 A to 2000 A1A± 1% ± 10 counts
  1mV/A 10x0.5 A A to 200 A (ac only)0.1 A± 1% ± 10 counts
Afund i430-Flex 1x5 A to 6000 A1 A± 0.5% ± 5 counts
  i430-Flex 10x0.5 A to 600 A0.1 A± 0.5% ± 5 counts
  1mV/A 1x5 A to 2000 A1A± 0.5% ± 5 counts
  1mV/A 10x0.5 A A to 200 A (ac only)0.1 A± 0.5% ± 5 counts
Hz
Hz Fluke 435 @ 50 Hz nominal
42.500 Hz to 57.500 Hz
0.001 Hz

± 0.01 Hz
Fluke 435 @ 60 Hz nominal 51.000 Hz to 69.000 Hz
0.001 Hz

± 0.01 Hz
Power
Watts (VA, var) i430-Flex
max 6000 MW0.1 W to 1 MW± 1% ± 10 counts
  1 mV/Amax 2000 MW0.1 W to 1 MW± 1% ± 10 counts
Power factor (Cos j/DPF) 0 to 10.001± 0.1% @ nominal load conditions
Energy
  kWh (kVAh, kvarh) i430-Flex 10xDepends on clamp scaling and V nominal± 1% ± 10 counts
  Energy loss i430-Flex 10xDepends on clamp scaling and V nominal± 1% ± 10 counts Excluding line resistance accuracy
Harmonics
Harmonic order (n) Harmonic order (n) DC, 1 to 50 Grouping: Harmonic groups according to IEC 61000-4-7
Inter-harmonic order (n) Inter-harmonic order (n) OFF, 1 to 50 Grouping: Harmonic and Interharmonic subgroups according to IEC 61000-4-7
Volts %f0.0 % to 100 %0.1 %± 0.1% ± n x 0.1 %
  %r0.0 % to 100 %0.1 %± 0.1% ± n x 0.4 %
  Absolute0.0 to 1000 V0.1 V± 5% *
  THD0.0 % to 100 %0.1 %± 2.5 %
Amps %f0.0 % to 100 %0.1 %± 0.1% ± n x 0.1%
  %r0.0 % to 100 %0.1 %± 0.1% ± n x 0.4 %
  Absolute0.0 to 600 A0.1 A± 5% ± 5 counts
  THD0.0 % to 100 %0.1 %± 2.5 %
Watts %f or %r0.0 % to 100 %0.1 %± n x 2%
  AbsoluteDepends on clamp scaling and V nominal-± 5% ± n x 2 % ± 10 counts
  THD0.0 % to 100 %0.1 %± 5 %
Phase Angle -360° to +0°± n x 1°
Flicker
Plt, Pst, Pst(1min) Pinst 0.00 to 20.000.01± 5 %
Unbalance
Volts %0.0 % to 20.0 %0.1 %± 0.1 %
Amps %0.0 % to 20.0 %0.1%± 1 %
Mains signaling
Threshold levels Threshold, limits and signaling duration is programable for two signaling frequencies--
Signaling frequency 60 Hz to 3000 Hz0.1 Hz
Relative V% 0 % to 100 %0.10 %± 0.4 %
Absolute V3s (3 second avg.) 0.0 V to 1000 V0.1 V± 5 % of nominal voltage
General specifications
CaseDesign Rugged, shock proof with integrated protective holster Drip and dust proof IP51 according to IEC60529 when used in tilt stand position Shock and vibration Shock 30 g, vibration: 3 g sinusoid, random 0.03 g 2 /Hz according to MIL-PRF-28800F Class 2
DisplayBrightness: 200 cd/m 2 typ. using power adapter, 90 cd/m 2 typical using battery power Size: 127 mm x 88 mm (153 mm/6.0 in diagonal) LCD Resolution: 320 x 240 pixels Contrast and brightness: user-adjustable, temperature compensated
Memory8GB SD card (SDHC compliant, FAT32 formatted) standard, upto 32GB optionally Screen save and multiple data memories for storing data including recordings (dependent on memory size)
Real-time clockTime and date stamp for Trend mode, Transient display, System Monitor and event capture
Environmental
Operating temperature0 °C ~ +40 °C; +40 °C ~ +50 °C excl. battery
Storage temperature-20 °C ~ +60 °C
Humidity +10 °C ~ +30 °C: 95% RH non-condensing
+30 °C ~ +40 °C: 75% RH non-condensing
+40 °C ~ +50 °C: 45% RH non-condensing
Maximum operating altitudeUp to 2,000 m (6666 ft) for CAT IV 600 V, CAT III 1000 V
Up to 3,000 m (10,000 ft) for CAT III 600 V, CAT II 1000 V
Maximum storage altitude 12 km (40,000 ft)
Electro-Magnetic-Compatibility (EMC)EN 61326 (2005-12) for emission and immunity
Interfacesmini-USB-B, Isolated USB port for PC connectivity SD card slot accessible behind instrument battery
WarrantyThree years (parts and labor) on main instrument, one year on accessories

Le Fluke 435-II comprend

  • Fluke 435-II Series of Power Quality Analyzers

Webinaire: Entretien des installations avec Fluke


Nous nous sommes associés à Fluke pour vous offrir une discussion approfondie sur les stratégies d’entretien proactives – approches, outils et mesures de «santé» appropriées sur les actifs essentiels. Comme la gestion des coûts énergétiques est également essentielle, nous explorerons également comment mettre en œuvre un programme de détection des fuites d’air comprimé et de gaz sur place, les établissements peuvent économiser des dizaines de milliers de dollars annuellement et réduire les temps d’arrêt de l’équipement de production. Les dernières avancées en matière d’équipement de test ont permis aux utilisateurs d’effectuer des inspections des fuites avec peu ou pas de formation en une fraction du temps par rapport aux outils conventionnels.

Au cours ce court webinaire sur l'entretien des installations, nous avons couvert:
  • Surveiller les actifs essentiels avec moins de ressources
  • Combler l’écart de compétences
  • Pourquoi remplaçons-nous les mêmes roulements et joints continuellement?
  • Quels sont les meilleurs outils à utiliser?
  • Comment justifions-nous le coût des outils et des ressources?
  • Comment amorçons-nous un programme d’entretien proactif?

Webinaire: Introduction aux analyseurs de puissance de précision portables


Cet analyseur de précision doté d’une large bande passante est suffisamment précis pour le laboratoire, mais il est conçu pour le terrain. Vous aurez plus de liberté que jamais pour effectuer des mesures de puissance de haute précision, où que vous soyez. En laboratoire comme sur le terrain. Conçu pour être transporté, l’analyseur élimine le besoin de transporter des analyseurs volumineux, fragiles et coûteux sur le terrain, vous permettant ainsi de faire des mesures directement à la charge dans presque tous les environnements. En mesurant directement à la charge, vous pouvez découvrir comment l’équipement fonctionne dans des conditions réelles, avec des variables réelles, pas seulement à un banc d’essai ou au laboratoire.

Durant ce webinaire d'une heure, nous avons couvert:
  • Le nouvel analyseur de puissance Fluke Norma 6000 pour des mesures précises à des fréquences allant de DC à 500 kHz
  • Ce n'est pas un analyseur de qualité de puissance.
  • Il s'agit d'un analyseur de puissance pour des mesures précises à des fréquences de DC à 500 kHz.
  • Il est conçu pour être utilisé sur le terrain, robuste, fonctionnant sur batterie, léger et adapté à une utilisation en dehors d'un environnement de laboratoire.
  • Vous découvrirez pourquoi il peut vous aider, où et comment il est utilisé

Cliquer sur une catégorie pour voir une sélection d'accessoires compatible avec le Fluke 435-II Series of Power Quality Analyzers.

Fluke TB25 Sac de rangement pour seau à outils, 5.2 gal TB25
Durable et robuste, ce sac de rangement de seau à outils a une capacité de 5.2 gallons sur laquelle on peut compter pour protéger et transporter en toute sécurité une variété d'outils et d'accessoires de test. Avec sa coque à fond rigide imperméable, cet organisateur polyvalent possède un total de 28 poches qui peuvent s'adapter aux outils à main, aux multimètres numériques, aux pinces ampèremétriques, aux sondes d'essai et plus encore.




Fluke i5sPQ3, 5A AC Current Clamps, 3-pack I5SPQ3
A pack of 3 pieces of the i5s current clamps, specially configured to provide low current accuracy while taking measurements on secondary current transformers.




Fluke i200s Adaptateur à pince de courant c.a. I200S
Une pince de courant à deux gammes (20A et 200A c.a.) avec une sortie sous forme d'un signal de tension via un connecteur BNC intégrant une isolation de sécurité.




Fluke i400s Pince à courant c.a. I400S
Pince à courant c.a. pour Fluke 787 & 789.




Fluke i1000S Sonde de courant à pince c.a. I1000S
Sondes de courant à pince c.a. étendent la fonctionnalité des oscilloscopes, compteurs de qualité de puissance ou multimètres numériques. Mesures de courant précises sans déconnecter le circuit.




Fluke i2000 FLEX Flexible AC Current Clamp I2000-FLEX
Utilizing the Rogowski principle, the clamp can be used to measure currents up to 2000 A when used in conjunction with multimeters, recorders, or data loggers. The flexible and lightweight measuring head allows quick and easy installation in hard to reach areas.




Fluke i3000s AC Current Clamp I3000S
3000A AC current clamp with BNC terminated lead




Fluke i3000s-FLEX-24 Sonde de courant à pince c.a. flexible I3000S-FLEX-24
Sonde de courant alternatif utilisant le principe Rogowski. Peut être utilisé pour mesurer les courants jusqu'à 3000A lorsqu'il est utilisé en conjonction avec oscilloscopes ou enregistreurs de données. Tête de mesure flexible à installation rapide dans les zones difficiles d'accès.




Fluke i6000s Flex-24 AC Current Probe I6000S-FLEX-24
Flexible 24" 6000A AC current probe with BNC terminated lead.




Fluke i6000s Flex-36 AC Current Probe I6000S-FLEX-36
Flexible 36" 6000A AC current probe with BNC terminated lead.




Fluke i30s Sonde de courant à pince c.a./c.c. I30S
Technologie à effet Hall pour des mesures précises à la fois de courant c.a. et c.c. Peut être utilisé en conjonction avec les oscilloscopes et autres instruments d'enregistrement appropriés pour la mesure de courant non-invasive précise.




Fluke 80I-110s AC/DC Current Clamp 80I-110s
The Fluke 80i-110s is optimized for accurate reproduction of currents at line frequency up to the 50th harmonic waveform.





Fluke AC285 Pinces crocodiles SureGrip™ AC285
Les surfaces surmoulées en caoutchouc et les formes ergonomiques garantissent un confort et une fiabilité optimaux pour permettre à l'utilisateur de se concentrer sur la prise de mesures précises.




Fluke BP290 Li-Ion Battery Pack BP290
For Fluke 43X power quality analyzers and 190-series ScopeMeters.




Fluke BP291 Double Capacity Li-Ion Battery Pack BP291
For Fluke 43X power quality analyzers and 190-series ScopeMeters.




Fluke EBC290 External Battery Charger EBC290
External battery charger for Li-ion batteries for 190B and 120B Series ScopeMeters and power quality analyzers.




Poser une question sur le Fluke 435-II Series of Power Quality Analyzers

Spécifications pour le Fluke 435-II

  ModelMeasurement rangeResolutionAccuracy
Volt
Vrms (ac+dc) 435-II1 V to 1000 V phase to neutral0.01 V± 0.1% of nominal voltage****
Vpk 1 Vpk to 1400 Vpk1 V5% of nominal voltage
Voltage Crest Factor (CF) 1.0 > 2.80.01± 5 %
Vrms½ 435-II0.1 V± 0.2% of nominal voltage
Vfund 435-II0.1 V± 0.1% of nominal voltage
Amps (accuracy excluding clamp accuracy)
Amps (ac +dc) i430-Flex 1x5 A to 6000 A1 A± 0.5% ± 5 counts
  i430-Flex 10x0.5 A to 600 A0.1 A± 0.5% ± 5 counts
  1mV/A 1x5 A to 2000 A1A± 0.5% ± 5 counts
  1mV/A 10x0.5 A A to 200 A (ac only)0.1 A± 0.5% ± 5 counts
Apk i430-Flex8400 Apk1 Arms± 5 %
  1mV/A5500 Apk1 Arms± 5 %
A Crest Factor (CF) 1 to 100.01± 5 %
Amps½ i430-Flex 1x5 A to 6000 A1 A± 1% ± 10 counts
  i430-Flex 10x0.5 A to 600 A0.1 A± 1% ± 10 counts
  1mV/A 1x5 A to 2000 A1A± 1% ± 10 counts
  1mV/A 10x0.5 A A to 200 A (ac only)0.1 A± 1% ± 10 counts
Afund i430-Flex 1x5 A to 6000 A1 A± 0.5% ± 5 counts
  i430-Flex 10x0.5 A to 600 A0.1 A± 0.5% ± 5 counts
  1mV/A 1x5 A to 2000 A1A± 0.5% ± 5 counts
  1mV/A 10x0.5 A A to 200 A (ac only)0.1 A± 0.5% ± 5 counts
Hz
Hz Fluke 435 @ 50 Hz nominal
42.500 Hz to 57.500 Hz
0.001 Hz

± 0.01 Hz
Fluke 435 @ 60 Hz nominal 51.000 Hz to 69.000 Hz
0.001 Hz

± 0.01 Hz
Power
Watts (VA, var) i430-Flex
max 6000 MW0.1 W to 1 MW± 1% ± 10 counts
  1 mV/Amax 2000 MW0.1 W to 1 MW± 1% ± 10 counts
Power factor (Cos j/DPF) 0 to 10.001± 0.1% @ nominal load conditions
Energy
  kWh (kVAh, kvarh) i430-Flex 10xDepends on clamp scaling and V nominal± 1% ± 10 counts
  Energy loss i430-Flex 10xDepends on clamp scaling and V nominal± 1% ± 10 counts Excluding line resistance accuracy
Harmonics
Harmonic order (n) Harmonic order (n) DC, 1 to 50 Grouping: Harmonic groups according to IEC 61000-4-7
Inter-harmonic order (n) Inter-harmonic order (n) OFF, 1 to 50 Grouping: Harmonic and Interharmonic subgroups according to IEC 61000-4-7
Volts %f0.0 % to 100 %0.1 %± 0.1% ± n x 0.1 %
  %r0.0 % to 100 %0.1 %± 0.1% ± n x 0.4 %
  Absolute0.0 to 1000 V0.1 V± 5% *
  THD0.0 % to 100 %0.1 %± 2.5 %
Amps %f0.0 % to 100 %0.1 %± 0.1% ± n x 0.1%
  %r0.0 % to 100 %0.1 %± 0.1% ± n x 0.4 %
  Absolute0.0 to 600 A0.1 A± 5% ± 5 counts
  THD0.0 % to 100 %0.1 %± 2.5 %
Watts %f or %r0.0 % to 100 %0.1 %± n x 2%
  AbsoluteDepends on clamp scaling and V nominal-± 5% ± n x 2 % ± 10 counts
  THD0.0 % to 100 %0.1 %± 5 %
Phase Angle -360° to +0°± n x 1°
Flicker
Plt, Pst, Pst(1min) Pinst 0.00 to 20.000.01± 5 %
Unbalance
Volts %0.0 % to 20.0 %0.1 %± 0.1 %
Amps %0.0 % to 20.0 %0.1%± 1 %
Mains signaling
Threshold levels Threshold, limits and signaling duration is programable for two signaling frequencies--
Signaling frequency 60 Hz to 3000 Hz0.1 Hz
Relative V% 0 % to 100 %0.10 %± 0.4 %
Absolute V3s (3 second avg.) 0.0 V to 1000 V0.1 V± 5 % of nominal voltage
General specifications
CaseDesign Rugged, shock proof with integrated protective holster Drip and dust proof IP51 according to IEC60529 when used in tilt stand position Shock and vibration Shock 30 g, vibration: 3 g sinusoid, random 0.03 g 2 /Hz according to MIL-PRF-28800F Class 2
DisplayBrightness: 200 cd/m 2 typ. using power adapter, 90 cd/m 2 typical using battery power Size: 127 mm x 88 mm (153 mm/6.0 in diagonal) LCD Resolution: 320 x 240 pixels Contrast and brightness: user-adjustable, temperature compensated
Memory8GB SD card (SDHC compliant, FAT32 formatted) standard, upto 32GB optionally Screen save and multiple data memories for storing data including recordings (dependent on memory size)
Real-time clockTime and date stamp for Trend mode, Transient display, System Monitor and event capture
Environmental
Operating temperature0 °C ~ +40 °C; +40 °C ~ +50 °C excl. battery
Storage temperature-20 °C ~ +60 °C
Humidity +10 °C ~ +30 °C: 95% RH non-condensing
+30 °C ~ +40 °C: 75% RH non-condensing
+40 °C ~ +50 °C: 45% RH non-condensing
Maximum operating altitudeUp to 2,000 m (6666 ft) for CAT IV 600 V, CAT III 1000 V
Up to 3,000 m (10,000 ft) for CAT III 600 V, CAT II 1000 V
Maximum storage altitude 12 km (40,000 ft)
Electro-Magnetic-Compatibility (EMC)EN 61326 (2005-12) for emission and immunity
Interfacesmini-USB-B, Isolated USB port for PC connectivity SD card slot accessible behind instrument battery
WarrantyThree years (parts and labor) on main instrument, one year on accessories

Le Fluke 435-II comprend

  • Fluke 435-II Series of Power Quality Analyzers

Webinaire: Entretien des installations avec Fluke


Nous nous sommes associés à Fluke pour vous offrir une discussion approfondie sur les stratégies d’entretien proactives – approches, outils et mesures de «santé» appropriées sur les actifs essentiels. Comme la gestion des coûts énergétiques est également essentielle, nous explorerons également comment mettre en œuvre un programme de détection des fuites d’air comprimé et de gaz sur place, les établissements peuvent économiser des dizaines de milliers de dollars annuellement et réduire les temps d’arrêt de l’équipement de production. Les dernières avancées en matière d’équipement de test ont permis aux utilisateurs d’effectuer des inspections des fuites avec peu ou pas de formation en une fraction du temps par rapport aux outils conventionnels.

Au cours ce court webinaire sur l'entretien des installations, nous avons couvert:
  • Surveiller les actifs essentiels avec moins de ressources
  • Combler l’écart de compétences
  • Pourquoi remplaçons-nous les mêmes roulements et joints continuellement?
  • Quels sont les meilleurs outils à utiliser?
  • Comment justifions-nous le coût des outils et des ressources?
  • Comment amorçons-nous un programme d’entretien proactif?

Webinaire: Introduction aux analyseurs de puissance de précision portables


Cet analyseur de précision doté d’une large bande passante est suffisamment précis pour le laboratoire, mais il est conçu pour le terrain. Vous aurez plus de liberté que jamais pour effectuer des mesures de puissance de haute précision, où que vous soyez. En laboratoire comme sur le terrain. Conçu pour être transporté, l’analyseur élimine le besoin de transporter des analyseurs volumineux, fragiles et coûteux sur le terrain, vous permettant ainsi de faire des mesures directement à la charge dans presque tous les environnements. En mesurant directement à la charge, vous pouvez découvrir comment l’équipement fonctionne dans des conditions réelles, avec des variables réelles, pas seulement à un banc d’essai ou au laboratoire.

Durant ce webinaire d'une heure, nous avons couvert:
  • Le nouvel analyseur de puissance Fluke Norma 6000 pour des mesures précises à des fréquences allant de DC à 500 kHz
  • Ce n'est pas un analyseur de qualité de puissance.
  • Il s'agit d'un analyseur de puissance pour des mesures précises à des fréquences de DC à 500 kHz.
  • Il est conçu pour être utilisé sur le terrain, robuste, fonctionnant sur batterie, léger et adapté à une utilisation en dehors d'un environnement de laboratoire.
  • Vous découvrirez pourquoi il peut vous aider, où et comment il est utilisé

Cliquer sur une catégorie pour voir une sélection d'accessoires compatible avec le Fluke 435-II Series of Power Quality Analyzers.

Fluke TB25 Sac de rangement pour seau à outils, 5.2 gal TB25
Durable et robuste, ce sac de rangement de seau à outils a une capacité de 5.2 gallons sur laquelle on peut compter pour protéger et transporter en toute sécurité une variété d'outils et d'accessoires de test. Avec sa coque à fond rigide imperméable, cet organisateur polyvalent possède un total de 28 poches qui peuvent s'adapter aux outils à main, aux multimètres numériques, aux pinces ampèremétriques, aux sondes d'essai et plus encore.




Fluke i5sPQ3, 5A AC Current Clamps, 3-pack I5SPQ3
A pack of 3 pieces of the i5s current clamps, specially configured to provide low current accuracy while taking measurements on secondary current transformers.




Fluke i200s Adaptateur à pince de courant c.a. I200S
Une pince de courant à deux gammes (20A et 200A c.a.) avec une sortie sous forme d'un signal de tension via un connecteur BNC intégrant une isolation de sécurité.




Fluke i400s Pince à courant c.a. I400S
Pince à courant c.a. pour Fluke 787 & 789.




Fluke i1000S Sonde de courant à pince c.a. I1000S
Sondes de courant à pince c.a. étendent la fonctionnalité des oscilloscopes, compteurs de qualité de puissance ou multimètres numériques. Mesures de courant précises sans déconnecter le circuit.




Fluke i2000 FLEX Flexible AC Current Clamp I2000-FLEX
Utilizing the Rogowski principle, the clamp can be used to measure currents up to 2000 A when used in conjunction with multimeters, recorders, or data loggers. The flexible and lightweight measuring head allows quick and easy installation in hard to reach areas.




Fluke i3000s AC Current Clamp I3000S
3000A AC current clamp with BNC terminated lead




Fluke i3000s-FLEX-24 Sonde de courant à pince c.a. flexible I3000S-FLEX-24
Sonde de courant alternatif utilisant le principe Rogowski. Peut être utilisé pour mesurer les courants jusqu'à 3000A lorsqu'il est utilisé en conjonction avec oscilloscopes ou enregistreurs de données. Tête de mesure flexible à installation rapide dans les zones difficiles d'accès.




Fluke i6000s Flex-24 AC Current Probe I6000S-FLEX-24
Flexible 24" 6000A AC current probe with BNC terminated lead.




Fluke i6000s Flex-36 AC Current Probe I6000S-FLEX-36
Flexible 36" 6000A AC current probe with BNC terminated lead.




Fluke i30s Sonde de courant à pince c.a./c.c. I30S
Technologie à effet Hall pour des mesures précises à la fois de courant c.a. et c.c. Peut être utilisé en conjonction avec les oscilloscopes et autres instruments d'enregistrement appropriés pour la mesure de courant non-invasive précise.




Fluke 80I-110s AC/DC Current Clamp 80I-110s
The Fluke 80i-110s is optimized for accurate reproduction of currents at line frequency up to the 50th harmonic waveform.





Fluke AC285 Pinces crocodiles SureGrip™ AC285
Les surfaces surmoulées en caoutchouc et les formes ergonomiques garantissent un confort et une fiabilité optimaux pour permettre à l'utilisateur de se concentrer sur la prise de mesures précises.




Fluke BP290 Li-Ion Battery Pack BP290
For Fluke 43X power quality analyzers and 190-series ScopeMeters.




Fluke BP291 Double Capacity Li-Ion Battery Pack BP291
For Fluke 43X power quality analyzers and 190-series ScopeMeters.




Fluke EBC290 External Battery Charger EBC290
External battery charger for Li-ion batteries for 190B and 120B Series ScopeMeters and power quality analyzers.




Poser une question sur le Fluke 435-II Series of Power Quality Analyzers