Fluke 1504-156 Specifications

Temperature Range Any thermistor range
Resistance Range 0W to 1mW, auto-ranging
Probe Thermistors
Characterizations Steinhart-Hart thermistor polynomial; Callendar-Van Dusen: R0, a, d and b
Resistance Accuracy (PPM Of Reading) 0W to 5kW: 0.5W; 5 to 200kW: 100ppm; 200kW to 1mW: 300ppm
Temperature Accuracy ±0.002°C at 0°C; ±0.002°C at 25°C; ±0.004°C at 50°C; ±0.010°C at 75°C; ±0.020°C at 100°C (using 10kW thermistor sensor, a=0.04; does not include probe uncertainty or characterization errors)
Operating Temperature Range 55.4 to 91.4°F (13 to 33°C)
Resistance Resolution 0W to 10kW: 0.01W; 10 to 100kW: 0.1W; 100kW to 1mW: 1W
Temperature Resolution 0.0001°C
Excitation Current 2 and 10mA, automatically selected
Measurement Period 1 second
Digital Filter Exponential, 0 to 60 seconds time constant (user selectable)
Probe Connection 4-wire with shield, 5-pin DIN connector
Communications RS-232 serial standard; IEEE-488 (GPIB) optional
Display 8-digit, 7-segment, yellow-green LED; 0.5in high characters
Power 115V AC (±10%), 50/60Hz, 1A, nominal; 230V AC (±10%), 50/60Hz, 1A, nominal, specify
Size (H x W x D) 2.4 x 5.6 x 7.1in (61 x 143 x 181mm)
Probes From Hart 5640-44, 5610-65
Calibration ISO 17025-accredited calibration provided
Cliquer ici pour toutes les spécifications du Fluke 1504-156

Le Fluke 1504-156 comprend

  • Fluke 1504-156 Thermometer Readout, Tweener Thermistor, ±0.002°C at 0°C Temperature Accuracy

Cliquer sur une catégorie pour voir une sélection d'accessoires compatible avec le Fluke 1504-156 Thermometer Readout, Tweener Thermistor, ±0.002°C at 0°C Temperature Accuracy.

Fluke TB25 Sac de rangement pour seau à outils, 5.2 gal TB25
Durable et robuste, ce sac de rangement de seau à outils a une capacité de 5.2 gallons sur laquelle on peut compter pour protéger et transporter en toute sécurité une variété d'outils et d'accessoires de test. Avec sa coque à fond rigide imperméable, cet organisateur polyvalent possède un total de 28 poches qui peuvent s'adapter aux outils à main, aux multimètres numériques, aux pinces ampèremétriques, aux sondes d'essai et plus encore.




Poser une question sur le Fluke 1504-156 Thermometer Readout, Tweener Thermistor, ±0.002°C at 0°C Temperature Accuracy

Fluke 1504-156 Specifications

Temperature Range Any thermistor range
Resistance Range 0W to 1mW, auto-ranging
Probe Thermistors
Characterizations Steinhart-Hart thermistor polynomial; Callendar-Van Dusen: R0, a, d and b
Resistance Accuracy (PPM Of Reading) 0W to 5kW: 0.5W; 5 to 200kW: 100ppm; 200kW to 1mW: 300ppm
Temperature Accuracy ±0.002°C at 0°C; ±0.002°C at 25°C; ±0.004°C at 50°C; ±0.010°C at 75°C; ±0.020°C at 100°C (using 10kW thermistor sensor, a=0.04; does not include probe uncertainty or characterization errors)
Operating Temperature Range 55.4 to 91.4°F (13 to 33°C)
Resistance Resolution 0W to 10kW: 0.01W; 10 to 100kW: 0.1W; 100kW to 1mW: 1W
Temperature Resolution 0.0001°C
Excitation Current 2 and 10mA, automatically selected
Measurement Period 1 second
Digital Filter Exponential, 0 to 60 seconds time constant (user selectable)
Probe Connection 4-wire with shield, 5-pin DIN connector
Communications RS-232 serial standard; IEEE-488 (GPIB) optional
Display 8-digit, 7-segment, yellow-green LED; 0.5in high characters
Power 115V AC (±10%), 50/60Hz, 1A, nominal; 230V AC (±10%), 50/60Hz, 1A, nominal, specify
Size (H x W x D) 2.4 x 5.6 x 7.1in (61 x 143 x 181mm)
Probes From Hart 5640-44, 5610-65
Calibration ISO 17025-accredited calibration provided
Cliquer ici pour toutes les spécifications du Fluke 1504-156

Le Fluke 1504-156 comprend

  • Fluke 1504-156 Thermometer Readout, Tweener Thermistor, ±0.002°C at 0°C Temperature Accuracy

Cliquer sur une catégorie pour voir une sélection d'accessoires compatible avec le Fluke 1504-156 Thermometer Readout, Tweener Thermistor, ±0.002°C at 0°C Temperature Accuracy.

Fluke TB25 Sac de rangement pour seau à outils, 5.2 gal TB25
Durable et robuste, ce sac de rangement de seau à outils a une capacité de 5.2 gallons sur laquelle on peut compter pour protéger et transporter en toute sécurité une variété d'outils et d'accessoires de test. Avec sa coque à fond rigide imperméable, cet organisateur polyvalent possède un total de 28 poches qui peuvent s'adapter aux outils à main, aux multimètres numériques, aux pinces ampèremétriques, aux sondes d'essai et plus encore.




Poser une question sur le Fluke 1504-156 Thermometer Readout, Tweener Thermistor, ±0.002°C at 0°C Temperature Accuracy

Plus de produits Fluke

Fluke Le prochain est à nos frais!