FLOMEC QS200-20 Insertion Ultrasonic Flowmeter for 2" pipes

Modèle: QS200-20PW

FLOMEC QS200-20 Insertion Ultrasonic Flowmeter for 2" pipes

Modèle: QS200-20PW

The ultrasonic flowmeter (for 2" pipes) provides an accurate reading of liquid flow rate and accumulated flow. It is designed to support commercial irrigation applications.

The ultrasonic flowmeter (for 2" pipes) provides an accurate reading of liquid flow rate and accumulated flow. It is designed to support commercial irrigation applications.

Discontinué!

Ce produit a été discontinué et n’est plus disponible.
Voici le produit de remplacement direct :

FLOMEC QS2-20-S-P QS200 Insertion Ultrasonic Flow Meter, PVC, socket, 2", 2-wire-

FLOMEC QS2-20-S-P QS200 Insertion Ultrasonic Flow Meter, PVC, socket, 2", 2-wire

Modèle: QS2-20-S-P | No. de commande: QS200-20

Providing accurate liquid flow rate and totalization for commercial irrigation applications, this 2" insertion ultrasonic flow sensor monitors flows from 0.1 to 15 fps (0.03 to 4.6 m/s) and operates below 140°f (60°c). In addition, its ultrasonic design eliminates moving parts, making it ideal for winterized systems and a direct replacement for paddlewheel sensors. it includes two 36" (914.4 mm) 18 awg solid copper wire leads with ul style 116666 direct burial insulation.


FLOMEC QS200-20PW offre

Caractéristiques

  • No moving mechanical parts (low-maintenance)
  • Simple two-wire connector (for power and pulse)
  • High accuracy: ±2.0% of reading (compared to full scale accuracy)
  • Provides extended leak detection down to 0.1 fps (0.03 m/s)
  • LED light indicators (green for power and amber for pulse)
  • Ideal for clean water flow measurement
  • External wiring (direct burial wire)

Applications

  • Agriculture irrigation
  • Turf/landscape irrigation systems
  • Micro irrigation systems
  • Groundwater monitoring

Spécifications pour le FLOMEC QS200-20PW

Operating Range
Minimum: 0.92 GPM (3.48 L minimum) 0.1' per second
Maximum: 138 GPM (522.39 L minimum) 15' per second
Maximum Water Pressure 150 psi at 73°F (10 bar at 23°C)
Temperature Rating Operating: 32 to 140°F (0 to 60°C)
Storage: -20 to 160°F (-29 to 71°C)
Flow Range 0.1 to 15 fps (0.03 to 4.57 m/s)
Accuracy Typically ±2% of reading
Operating Pressure 150 psi at 73°F (10 bar at 23°C)
100 psi at 140°F (7 bar at 60°C)
Output Frequency 0 to 100 Hz
Pipe Size 2" (51 mm)

Le FLOMEC QS200-20PW comprend

  • FLOMEC QS200-20 Insertion Ultrasonic Flowmeter for 2" pipes

Poser une question sur le FLOMEC QS200-20 Insertion Ultrasonic Flowmeter for 2" pipes

FLOMEC QS200-20PW offre

Caractéristiques

  • No moving mechanical parts (low-maintenance)
  • Simple two-wire connector (for power and pulse)
  • High accuracy: ±2.0% of reading (compared to full scale accuracy)
  • Provides extended leak detection down to 0.1 fps (0.03 m/s)
  • LED light indicators (green for power and amber for pulse)
  • Ideal for clean water flow measurement
  • External wiring (direct burial wire)

Applications

  • Agriculture irrigation
  • Turf/landscape irrigation systems
  • Micro irrigation systems
  • Groundwater monitoring

Spécifications pour le FLOMEC QS200-20PW

Operating Range
Minimum: 0.92 GPM (3.48 L minimum) 0.1' per second
Maximum: 138 GPM (522.39 L minimum) 15' per second
Maximum Water Pressure 150 psi at 73°F (10 bar at 23°C)
Temperature Rating Operating: 32 to 140°F (0 to 60°C)
Storage: -20 to 160°F (-29 to 71°C)
Flow Range 0.1 to 15 fps (0.03 to 4.57 m/s)
Accuracy Typically ±2% of reading
Operating Pressure 150 psi at 73°F (10 bar at 23°C)
100 psi at 140°F (7 bar at 60°C)
Output Frequency 0 to 100 Hz
Pipe Size 2" (51 mm)

Le FLOMEC QS200-20PW comprend

  • FLOMEC QS200-20 Insertion Ultrasonic Flowmeter for 2" pipes

Poser une question sur le FLOMEC QS200-20 Insertion Ultrasonic Flowmeter for 2" pipes

Plus de produits FLOMEC