FLIR A500 Standard Science Kit, 24°

Modèle: A500 | No. de commande: 90610-0202 | CUP: 7332558029244

FLIR A500 Standard Science Kit, 24°

Modèle: A500 | No. de commande: 90610-0202 | CUP: 7332558029244

Work with unparalleled accuracy, connectivity, and analysis with this standard science kit that features Macro mode for superior flexibility and a 24° lens with automatic/remote and manual focusing. This kit comes equipped with an image streaming camera and a lens.

Work with unparalleled accuracy, connectivity, and analysis with this standard science kit that features Macro mode for superior flexibility and a 24° lens with automatic/remote and manual focusing. This kit comes equipped with an image streaming camera and a lens.

Votre prix $26127.00 CAD
Disponibilité 2 à 3 semaines
Quantité

FLIR A500 Offers

For researchers, engineers, electronics, aerospace, and life sciences, this kit offers unparalleled thermal imaging and innovations, simplified data analysis, sharing, and collaboration with advanced features for unmatched connectivity.

Unparalleled thermal imaging and innovations

Get accurate thermal data on your entire device and individual subcomponents

  • Obtain correct thermal measurements with crisp remote, automatic, and manual focusing
  • Multiple lens options ensure you get the maximum number of pixels on your test article
  • Accurately measure temperatures on small objects without the need to switch lenses using the included one-touch enabled macro mode

Simplified data analysis, sharing, and collaboration

Start collecting and sharing meaningful data with limited ramp-up time and simple connections

  • Employ research studio's simple Connect➞View➞Record➞Analyze workflow to obtain and analyze thermal results quickly
  • Work in the operating system you prefer and share data globally with colleagues in their preferred language

Advanced features for unmatched connectivity

Get up and running faster with simple yet robust connections

  • Ensure camera connections are correct and secure with M-style, positive lock connectors
  • Eliminate the need for additional cables using standard Power over ethernet (PoE)
  • Control camera parameters and recording through digital I/O

Applications

  • Research and development
  • Engineers
  • Electronics
  • Aerospace
  • Life sciences

FLIR A500 Specifications

Detector data
IR Resolution 464 x 348
Thermal Resolution/NETD <30 to <50 mK - Lens dependent
Focal Plane Array/Spectral Range Uncooled microbolometer
Detector Pitch 17 µm
Spectral Range 7.5 to 14 µm
Frame Rate 30 Hz
Image and optical data
Camera F/# Lens dependent
Lenses 24°
Macro Mode Included
Lens Identification Automatic
Focus One-shot contrast, motorized, manual
Minimum Focus Distance 24°: 0.49' (0.15 m)
24° with macro mode: 0.67" (17 mm)
Measurement
Standard Temperature Ranges 572 to 2732°F (300 to 1500°C)
Accuracy ±3.6°F (±2°C) or ±2% of reading for ambient temperature
59 to 95°F (15 to 35°C)
Object temperature above 32°F (0°C)
Image presentation
Digital Data Via workstation running included research studio software
Data Streaming and Control Gigabit ethernet (RTSP, GigE vision)
Dynamic Range 16-bit
Images modes in research studio
Infrared Yes
Gigabit ethernet
Ethernet Image Streaming Yes
Connector Type M12 8-pin X-coded, female
Ethernet Power: Power over Ethernet, PoE IEEE 802.3af class 3
Communication: GigE Vision version 1.2, client API GenICam compliant, TCP/IP socket-based (Proprietary)
Digital input/output
Connector Type M12 male 12-pin A-coded (shared with ext. power)
Digital Input: 2x opto-isolated, vin (low) = 0 to 1.5 V, vin (high) = 3 to 25 V
Output: 3x opto-isolated, 0 to 48 V DC, maximum 350 mA (derated to 200 mA at 60°C). Solid-state opto relay, 1x dedicated as fault output (NC)
General Specifications
Connector Type M12 male 12-pin A-coded (shared with digital I/O)
General Power over ethernet or external
External Voltage 24/48 V DC, 8 W maximum
Temperature Range Operating: -4 to 104°F (-20 to 40°C), in free air
104 to 122°F (40 to 50°C)
Maximum camera case temperature: 149°F (65°C)
Storage: IEC 68-2-1 and IEC 68-2-2, -40 to 158°F (-40 to 70°C) for 16 hours
Shock IEC 60068-2-27, 0.05 lbs (25 g)
Vibration IEC 60068-2-6, 0.005" (0.15 mm) at 10 to 58 Hz and 0.004 lbs (2 g) at 58 to 500 Hz, sinusoidal
Power 24/48 V DC 8 W maximum
Mounting UNC ¼" to 20 on 2 sides
4 x M4 on 4 sides
Dimensions 4.84 x 3.03 x 3.03" (123 x 77 x 77 mm)
Weight 1.8 lbs (0.82 kg) including 24° lens
Cliquer ici pour toutes les spécifications du FLIR A500

What's included with the FLIR A500

  • Image Streaming Camera
  • Lens

Cliquer sur une catégorie pour voir une sélection d'accessoires compatible avec le FLIR A500 Standard Science Kit, 24°.

FLIR T911850ACC Antenna for WLAN 2.4/5 GHz T911850ACC
For use with the A400/A700 Thermal Smart Sensor configuration, A400/A700 Thermal Image Streaming configuration, and the GF77a Uncooled Autonomous Infrared Camera.




FLIR T911852ACC Cable M12 to Pigtail, 6.6' T911852ACC
A 6.6' (2 m) cable for use with the A400/A700 Thermal Smart Sensor configuration, A400/A700 Thermal Image Streaming configuration, and the GF77a Uncooled Autonomous Infrared Camera.




FLIR T911853ACC Cable M12 to Pigtail, 32.8' T911853ACC
A 32.8' (10 m) cable for use with the A400/A700 Thermal Smart Sensor configuration, A400/A700 Thermal Image Streaming configuration, and the GF77a Uncooled Autonomous Infrared Camera.




FLIR T911854ACC Ethernet Cable M12 to RJ45, 6.6' T911854ACC
A 6.6' (2 m) M12 to RJ45, X-coded ethernet cable for use with the A400/A700 Thermal Smart Sensor configuration, A400/A700 Thermal Image Streaming configuration, and the GF77a Uncooled Autonomous Infrared Camera.




FLIR T911855ACC Ethernet Cable M12 to RJ45, 32.8' T911855ACC
A 32.8' (10 m) M12 to RJ45, X-coded ethernet cable for use with the A400/A700 Thermal Smart Sensor configuration, A400/A700 Thermal Image Streaming configuration, and the GF77a Uncooled Autonomous Infrared Camera.




FLIR T911869ACC Ethernet Cable M12 to RJ45F, 0.98' T911869ACC
A 0.98' (0.3 m) M12 to RJ45F, X-coded ethernet cable for use with the A400/A700 Thermal Smart Sensor configuration, A400/A700 Thermal Image Streaming configuration, and the GF77a Uncooled Autonomous Infrared Camera.




FLIR T951004ACC Ethernet Cable CAT-6, 2m T951004ACC
Cable used to connect an Ax5 Series Infrared Camera to the Ethernet. RJ-45 to RJ-45 connectors.




FLIR T300586 Objectif infrarouge pour la série Axxx, f=17/29 mm double champ de vision T300586
Compatible avec les caméras à imagerie thermique de la série Axxx, cet objectif infrarouge offre un champ de vision double (14° et 24°) dans un seul objectif.




FLIR T199507 PoE injector and Cable Kit Mains for the FLIR A400/A700 series and FLIR GF77a T199507
This Gigabit PoE injector is an accessory for the following products: FLIR A400/A700 Thermal Smart Sensor configuration, FLIR A400/A700 Thermal Image Streaming configuration, and FLIR GF77a.




Poser une question sur le FLIR A500 Standard Science Kit, 24°

FLIR A500 Offers

For researchers, engineers, electronics, aerospace, and life sciences, this kit offers unparalleled thermal imaging and innovations, simplified data analysis, sharing, and collaboration with advanced features for unmatched connectivity.

Unparalleled thermal imaging and innovations

Get accurate thermal data on your entire device and individual subcomponents

  • Obtain correct thermal measurements with crisp remote, automatic, and manual focusing
  • Multiple lens options ensure you get the maximum number of pixels on your test article
  • Accurately measure temperatures on small objects without the need to switch lenses using the included one-touch enabled macro mode

Simplified data analysis, sharing, and collaboration

Start collecting and sharing meaningful data with limited ramp-up time and simple connections

  • Employ research studio's simple Connect➞View➞Record➞Analyze workflow to obtain and analyze thermal results quickly
  • Work in the operating system you prefer and share data globally with colleagues in their preferred language

Advanced features for unmatched connectivity

Get up and running faster with simple yet robust connections

  • Ensure camera connections are correct and secure with M-style, positive lock connectors
  • Eliminate the need for additional cables using standard Power over ethernet (PoE)
  • Control camera parameters and recording through digital I/O

Applications

  • Research and development
  • Engineers
  • Electronics
  • Aerospace
  • Life sciences

FLIR A500 Specifications

Detector data
IR Resolution 464 x 348
Thermal Resolution/NETD <30 to <50 mK - Lens dependent
Focal Plane Array/Spectral Range Uncooled microbolometer
Detector Pitch 17 µm
Spectral Range 7.5 to 14 µm
Frame Rate 30 Hz
Image and optical data
Camera F/# Lens dependent
Lenses 24°
Macro Mode Included
Lens Identification Automatic
Focus One-shot contrast, motorized, manual
Minimum Focus Distance 24°: 0.49' (0.15 m)
24° with macro mode: 0.67" (17 mm)
Measurement
Standard Temperature Ranges 572 to 2732°F (300 to 1500°C)
Accuracy ±3.6°F (±2°C) or ±2% of reading for ambient temperature
59 to 95°F (15 to 35°C)
Object temperature above 32°F (0°C)
Image presentation
Digital Data Via workstation running included research studio software
Data Streaming and Control Gigabit ethernet (RTSP, GigE vision)
Dynamic Range 16-bit
Images modes in research studio
Infrared Yes
Gigabit ethernet
Ethernet Image Streaming Yes
Connector Type M12 8-pin X-coded, female
Ethernet Power: Power over Ethernet, PoE IEEE 802.3af class 3
Communication: GigE Vision version 1.2, client API GenICam compliant, TCP/IP socket-based (Proprietary)
Digital input/output
Connector Type M12 male 12-pin A-coded (shared with ext. power)
Digital Input: 2x opto-isolated, vin (low) = 0 to 1.5 V, vin (high) = 3 to 25 V
Output: 3x opto-isolated, 0 to 48 V DC, maximum 350 mA (derated to 200 mA at 60°C). Solid-state opto relay, 1x dedicated as fault output (NC)
General Specifications
Connector Type M12 male 12-pin A-coded (shared with digital I/O)
General Power over ethernet or external
External Voltage 24/48 V DC, 8 W maximum
Temperature Range Operating: -4 to 104°F (-20 to 40°C), in free air
104 to 122°F (40 to 50°C)
Maximum camera case temperature: 149°F (65°C)
Storage: IEC 68-2-1 and IEC 68-2-2, -40 to 158°F (-40 to 70°C) for 16 hours
Shock IEC 60068-2-27, 0.05 lbs (25 g)
Vibration IEC 60068-2-6, 0.005" (0.15 mm) at 10 to 58 Hz and 0.004 lbs (2 g) at 58 to 500 Hz, sinusoidal
Power 24/48 V DC 8 W maximum
Mounting UNC ¼" to 20 on 2 sides
4 x M4 on 4 sides
Dimensions 4.84 x 3.03 x 3.03" (123 x 77 x 77 mm)
Weight 1.8 lbs (0.82 kg) including 24° lens
Cliquer ici pour toutes les spécifications du FLIR A500

What's included with the FLIR A500

  • Image Streaming Camera
  • Lens

Cliquer sur une catégorie pour voir une sélection d'accessoires compatible avec le FLIR A500 Standard Science Kit, 24°.

FLIR T911850ACC Antenna for WLAN 2.4/5 GHz T911850ACC
For use with the A400/A700 Thermal Smart Sensor configuration, A400/A700 Thermal Image Streaming configuration, and the GF77a Uncooled Autonomous Infrared Camera.




FLIR T911852ACC Cable M12 to Pigtail, 6.6' T911852ACC
A 6.6' (2 m) cable for use with the A400/A700 Thermal Smart Sensor configuration, A400/A700 Thermal Image Streaming configuration, and the GF77a Uncooled Autonomous Infrared Camera.




FLIR T911853ACC Cable M12 to Pigtail, 32.8' T911853ACC
A 32.8' (10 m) cable for use with the A400/A700 Thermal Smart Sensor configuration, A400/A700 Thermal Image Streaming configuration, and the GF77a Uncooled Autonomous Infrared Camera.




FLIR T911854ACC Ethernet Cable M12 to RJ45, 6.6' T911854ACC
A 6.6' (2 m) M12 to RJ45, X-coded ethernet cable for use with the A400/A700 Thermal Smart Sensor configuration, A400/A700 Thermal Image Streaming configuration, and the GF77a Uncooled Autonomous Infrared Camera.




FLIR T911855ACC Ethernet Cable M12 to RJ45, 32.8' T911855ACC
A 32.8' (10 m) M12 to RJ45, X-coded ethernet cable for use with the A400/A700 Thermal Smart Sensor configuration, A400/A700 Thermal Image Streaming configuration, and the GF77a Uncooled Autonomous Infrared Camera.




FLIR T911869ACC Ethernet Cable M12 to RJ45F, 0.98' T911869ACC
A 0.98' (0.3 m) M12 to RJ45F, X-coded ethernet cable for use with the A400/A700 Thermal Smart Sensor configuration, A400/A700 Thermal Image Streaming configuration, and the GF77a Uncooled Autonomous Infrared Camera.




FLIR T951004ACC Ethernet Cable CAT-6, 2m T951004ACC
Cable used to connect an Ax5 Series Infrared Camera to the Ethernet. RJ-45 to RJ-45 connectors.




FLIR T300586 Objectif infrarouge pour la série Axxx, f=17/29 mm double champ de vision T300586
Compatible avec les caméras à imagerie thermique de la série Axxx, cet objectif infrarouge offre un champ de vision double (14° et 24°) dans un seul objectif.




FLIR T199507 PoE injector and Cable Kit Mains for the FLIR A400/A700 series and FLIR GF77a T199507
This Gigabit PoE injector is an accessory for the following products: FLIR A400/A700 Thermal Smart Sensor configuration, FLIR A400/A700 Thermal Image Streaming configuration, and FLIR GF77a.




Poser une question sur le FLIR A500 Standard Science Kit, 24°

Plus de produits FLIR